隐形眼镜引起的不适和泪液中炎症介质的变化

Simin Masoudi, Zhenjun Zhao, F. Stapleton, M. Willcox
{"title":"隐形眼镜引起的不适和泪液中炎症介质的变化","authors":"Simin Masoudi, Zhenjun Zhao, F. Stapleton, M. Willcox","doi":"10.1097/ICL.0000000000000237","DOIUrl":null,"url":null,"abstract":"Purpose: Studies indicate that contact lens (CL) discontinuation mostly occurs because of dryness and discomfort symptoms. This study aimed to investigate relationships between changes in the concentration of tear inflammatory mediators with subjective comfort ratings with CL wear and no contact lens wear between morning and evening. Method: Forty-five subjects collected tears twice daily in the morning and in the evening with or without lenses. Comfort was rated subjectively on a scale from 1 to 100 (where 100 was extremely comfortable) just before each tear collection. Tear samples were assayed for complement components (C3 and C3a), leukotriene B4 (LTB4), secretory phospholipase A2 (sPLA2), secretory immunoglobulin A (sIgA), and bradykinin using commercially available immuno-based assay kits. Results: Comfort ratings showed a statistically significant decline from morning to evening both with CL (89.0±10.1 AM vs. 76.7±15.2 PM; P<0.001) and without CL (89.1±10.2 AM vs. 84.2±12.6 PM; P<0.005) wear. The decline was steeper with lens wear (P<0.001). Bradykinin and sPLA2 levels did not change between morning and evening or with CL wear (P>0.05). Leukotriene B4 levels were slightly higher in CL (CL 43.4±12.6 pg/ml vs. No CL 39.4±13.4 pg/mL; P=0.034), whereas the concentration of LTB4, C3, C3a, and sIgA dropped by the end of the day in the presence or absence of lens wear (P<0.001). For most mediators, tear levels were not correlated with comfort ratings in any of the conditions. Leukotriene B4 had a higher concentration in the evening, and when measured as a ratio to sIgA, there was a trend for increased concentration of this mediator during CL wear. Conclusion: Although specific mediators showed changes from morning to evening with and without lens wear, most of these were not correlated with subjective comfort ratings in lens wear. The only mediator that showed an increase in concentration during the day and during lens wear was LTB4, and further studies on this mediator are warranted.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"19 1","pages":"40–45"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"31","resultStr":"{\"title\":\"Contact Lens–Induced Discomfort and Inflammatory Mediator Changes in Tears\",\"authors\":\"Simin Masoudi, Zhenjun Zhao, F. Stapleton, M. Willcox\",\"doi\":\"10.1097/ICL.0000000000000237\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: Studies indicate that contact lens (CL) discontinuation mostly occurs because of dryness and discomfort symptoms. This study aimed to investigate relationships between changes in the concentration of tear inflammatory mediators with subjective comfort ratings with CL wear and no contact lens wear between morning and evening. Method: Forty-five subjects collected tears twice daily in the morning and in the evening with or without lenses. Comfort was rated subjectively on a scale from 1 to 100 (where 100 was extremely comfortable) just before each tear collection. Tear samples were assayed for complement components (C3 and C3a), leukotriene B4 (LTB4), secretory phospholipase A2 (sPLA2), secretory immunoglobulin A (sIgA), and bradykinin using commercially available immuno-based assay kits. Results: Comfort ratings showed a statistically significant decline from morning to evening both with CL (89.0±10.1 AM vs. 76.7±15.2 PM; P<0.001) and without CL (89.1±10.2 AM vs. 84.2±12.6 PM; P<0.005) wear. The decline was steeper with lens wear (P<0.001). Bradykinin and sPLA2 levels did not change between morning and evening or with CL wear (P>0.05). Leukotriene B4 levels were slightly higher in CL (CL 43.4±12.6 pg/ml vs. No CL 39.4±13.4 pg/mL; P=0.034), whereas the concentration of LTB4, C3, C3a, and sIgA dropped by the end of the day in the presence or absence of lens wear (P<0.001). For most mediators, tear levels were not correlated with comfort ratings in any of the conditions. Leukotriene B4 had a higher concentration in the evening, and when measured as a ratio to sIgA, there was a trend for increased concentration of this mediator during CL wear. Conclusion: Although specific mediators showed changes from morning to evening with and without lens wear, most of these were not correlated with subjective comfort ratings in lens wear. The only mediator that showed an increase in concentration during the day and during lens wear was LTB4, and further studies on this mediator are warranted.\",\"PeriodicalId\":12216,\"journal\":{\"name\":\"Eye & Contact Lens: Science & Clinical Practice\",\"volume\":\"19 1\",\"pages\":\"40–45\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"31\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye & Contact Lens: Science & Clinical Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/ICL.0000000000000237\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens: Science & Clinical Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000000237","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 31

摘要

目的:研究表明,隐形眼镜(CL)停戴主要是由于干燥和不适症状。本研究旨在探讨早晚佩戴CL和不佩戴隐形眼镜时泪液炎症介质浓度变化与主观舒适度之间的关系。方法:45例受试者每天早晚两次采集泪液,佩戴或不佩戴隐形眼镜。在每次收集眼泪之前,舒适度被主观地评定为从1到100的等级(其中100表示非常舒适)。泪液样品采用市售免疫检测试剂盒检测补体成分(C3和C3a)、白三烯B4 (LTB4)、分泌性磷脂酶A2 (sPLA2)、分泌性免疫球蛋白A (sIgA)和缓激肽。结果:舒适度评分从早上到晚上都有统计学上的显著下降(89.0±10.1 AM vs 76.7±15.2 PM;P0.05)。CL组白三烯B4水平略高(CL为43.4±12.6 pg/ml, CL为39.4±13.4 pg/ml;P=0.034),而LTB4、C3、C3a和sIgA的浓度在有或没有镜片磨损的情况下在一天结束时下降(P<0.001)。对于大多数调解者来说,在任何条件下,眼泪水平都与舒适度评级无关。白三烯B4在晚上的浓度较高,当与sIgA的比值测量时,这种介质的浓度在CL磨损期间有增加的趋势。结论:虽然在佩戴和不佩戴隐形眼镜的情况下,特定的调节因子从早上到晚上都有变化,但大多数与佩戴隐形眼镜的主观舒适度评分无关。唯一在白天和镜片磨损期间显示浓度增加的介质是LTB4,对该介质的进一步研究是有必要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Contact Lens–Induced Discomfort and Inflammatory Mediator Changes in Tears
Purpose: Studies indicate that contact lens (CL) discontinuation mostly occurs because of dryness and discomfort symptoms. This study aimed to investigate relationships between changes in the concentration of tear inflammatory mediators with subjective comfort ratings with CL wear and no contact lens wear between morning and evening. Method: Forty-five subjects collected tears twice daily in the morning and in the evening with or without lenses. Comfort was rated subjectively on a scale from 1 to 100 (where 100 was extremely comfortable) just before each tear collection. Tear samples were assayed for complement components (C3 and C3a), leukotriene B4 (LTB4), secretory phospholipase A2 (sPLA2), secretory immunoglobulin A (sIgA), and bradykinin using commercially available immuno-based assay kits. Results: Comfort ratings showed a statistically significant decline from morning to evening both with CL (89.0±10.1 AM vs. 76.7±15.2 PM; P<0.001) and without CL (89.1±10.2 AM vs. 84.2±12.6 PM; P<0.005) wear. The decline was steeper with lens wear (P<0.001). Bradykinin and sPLA2 levels did not change between morning and evening or with CL wear (P>0.05). Leukotriene B4 levels were slightly higher in CL (CL 43.4±12.6 pg/ml vs. No CL 39.4±13.4 pg/mL; P=0.034), whereas the concentration of LTB4, C3, C3a, and sIgA dropped by the end of the day in the presence or absence of lens wear (P<0.001). For most mediators, tear levels were not correlated with comfort ratings in any of the conditions. Leukotriene B4 had a higher concentration in the evening, and when measured as a ratio to sIgA, there was a trend for increased concentration of this mediator during CL wear. Conclusion: Although specific mediators showed changes from morning to evening with and without lens wear, most of these were not correlated with subjective comfort ratings in lens wear. The only mediator that showed an increase in concentration during the day and during lens wear was LTB4, and further studies on this mediator are warranted.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信