从实验中得到了改进策略对波函数的影响

Bruno Landeros‐Rivera, J. Contreras‐García, P. Dominiak
{"title":"从实验中得到了改进策略对波函数的影响","authors":"Bruno Landeros‐Rivera, J. Contreras‐García, P. Dominiak","doi":"10.1107/s2052520621008258","DOIUrl":null,"url":null,"abstract":"The synergy between theory and experiment found in X-ray wavefunction refinement (XWR) makes it one of the most compelling techniques available for chemical physics. The foremost benefit of XWR – obtaining wavefunctions constrained to experimental data – is at the same time its Achilles heel, because of the dependence of the results on the quality of both empirical and theoretical data. The purpose of this work is to answer the following: What is the effect of the refinement strategy and manipulation of input data on the physical properties obtained from XWR? With that in mind, cutoffs based on data resolution and F/σ(F) ratios were applied for both steps of XWR, the Hirshfeld atom refinement (HAR) and the X-ray constrained wavefunction fitting (XCW), for four selected systems: sulfur dioxide, urea, carbamazepine and oxalic acid. The effects of changing the weighting scheme or the method to transform σ(F\n 2) to σ(F) were also analysed. The results show that while HAR always reaches the same result, XCW is extremely sensitive to crystallographic data manipulation. This is a result of the variability of the experimental uncertainties for different resolution shells, and of not having proper standard uncertainties. Therefore, the use of distinct constraints for each resolution interval in XCW is proposed to fix this instability.","PeriodicalId":7080,"journal":{"name":"Acta Crystallographica Section B Structural Science, Crystal Engineering and Materials","volume":"10 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The influence of refinement strategies on the wavefunctions derived from an experiment\",\"authors\":\"Bruno Landeros‐Rivera, J. Contreras‐García, P. Dominiak\",\"doi\":\"10.1107/s2052520621008258\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The synergy between theory and experiment found in X-ray wavefunction refinement (XWR) makes it one of the most compelling techniques available for chemical physics. The foremost benefit of XWR – obtaining wavefunctions constrained to experimental data – is at the same time its Achilles heel, because of the dependence of the results on the quality of both empirical and theoretical data. The purpose of this work is to answer the following: What is the effect of the refinement strategy and manipulation of input data on the physical properties obtained from XWR? With that in mind, cutoffs based on data resolution and F/σ(F) ratios were applied for both steps of XWR, the Hirshfeld atom refinement (HAR) and the X-ray constrained wavefunction fitting (XCW), for four selected systems: sulfur dioxide, urea, carbamazepine and oxalic acid. The effects of changing the weighting scheme or the method to transform σ(F\\n 2) to σ(F) were also analysed. The results show that while HAR always reaches the same result, XCW is extremely sensitive to crystallographic data manipulation. This is a result of the variability of the experimental uncertainties for different resolution shells, and of not having proper standard uncertainties. Therefore, the use of distinct constraints for each resolution interval in XCW is proposed to fix this instability.\",\"PeriodicalId\":7080,\"journal\":{\"name\":\"Acta Crystallographica Section B Structural Science, Crystal Engineering and Materials\",\"volume\":\"10 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Crystallographica Section B Structural Science, Crystal Engineering and Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1107/s2052520621008258\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Crystallographica Section B Structural Science, Crystal Engineering and Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1107/s2052520621008258","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在x射线波函数精化(XWR)中发现的理论和实验之间的协同作用使其成为化学物理中最引人注目的技术之一。XWR的最大优点——获得受实验数据约束的波函数——同时也是它的致命弱点,因为结果依赖于经验数据和理论数据的质量。这项工作的目的是回答以下问题:精炼策略和输入数据的操作对从XWR获得的物理属性有什么影响?考虑到这一点,基于数据分辨率和F/σ(F)比的截止值应用于XWR的两个步骤,Hirshfeld原子精化(HAR)和x射线约束波函数拟合(XCW),选择了四种体系:二氧化硫,尿素,卡马西平和草酸。同时分析了不同的权重形式和将σ(f2)变换为σ(F)的方法所产生的影响。结果表明,HAR总是能得到相同的结果,而XCW对晶体学数据的操纵极为敏感。这是由于不同分辨率壳层的实验不确定度的变化,以及没有适当的标准不确定度的结果。因此,建议在XCW中对每个分辨率区间使用不同的约束来解决这种不稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The influence of refinement strategies on the wavefunctions derived from an experiment
The synergy between theory and experiment found in X-ray wavefunction refinement (XWR) makes it one of the most compelling techniques available for chemical physics. The foremost benefit of XWR – obtaining wavefunctions constrained to experimental data – is at the same time its Achilles heel, because of the dependence of the results on the quality of both empirical and theoretical data. The purpose of this work is to answer the following: What is the effect of the refinement strategy and manipulation of input data on the physical properties obtained from XWR? With that in mind, cutoffs based on data resolution and F/σ(F) ratios were applied for both steps of XWR, the Hirshfeld atom refinement (HAR) and the X-ray constrained wavefunction fitting (XCW), for four selected systems: sulfur dioxide, urea, carbamazepine and oxalic acid. The effects of changing the weighting scheme or the method to transform σ(F 2) to σ(F) were also analysed. The results show that while HAR always reaches the same result, XCW is extremely sensitive to crystallographic data manipulation. This is a result of the variability of the experimental uncertainties for different resolution shells, and of not having proper standard uncertainties. Therefore, the use of distinct constraints for each resolution interval in XCW is proposed to fix this instability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信