P. Tien, S. Wei, T. Chow, J. Darkwa, Christopher Wood, J. Calautit
{"title":"提高基于视觉的建筑物占用探测器的检测性能","authors":"P. Tien, S. Wei, T. Chow, J. Darkwa, Christopher Wood, J. Calautit","doi":"10.1680/jensu.22.00013","DOIUrl":null,"url":null,"abstract":"Occupant behaviour is one of the key parameters that significantly impact the operation of heating, ventilation, and air-conditioning (HVAC) systems and the energy performance of buildings. The detailed occupancy information can improve HVAC operation and utilisation of building spaces. Strategies such as vision-based occupancy detection and recognition have recently garnered much interest. This study investigates the performance of a vision-based deep learning detection technique for enhancing building system operations and energy performances. The model used was the Faster RCNN with Inception V2. Two occupancy detection model configurations were developed, tested and evaluated. Both models were analysed based on the application of the detector within a selected case study building, along with the evaluation based on the different evaluation metrics. Results suggest that the occupancy detector (Model 1) provided an overall accuracy of 95.23% and an F1 score of 0.9756, while the occupancy activity detector (Model 2) provided an accuracy of 89.37% with an F1 score of 0.8298. Building Energy Simulation (BES) was used to evaluate and compare the impact of such an approach on the indoor occupancy heat gains. The study highlighted the potential of the detection approaches, but further development is necessary, including optimisation of the model, full integration with HVAC controls and further model training and field testing.","PeriodicalId":49671,"journal":{"name":"Proceedings of the Institution of Civil Engineers-Engineering Sustainability","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2022-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enhancing the detection performance of a vision-based occupancy detector for buildings\",\"authors\":\"P. Tien, S. Wei, T. Chow, J. Darkwa, Christopher Wood, J. Calautit\",\"doi\":\"10.1680/jensu.22.00013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Occupant behaviour is one of the key parameters that significantly impact the operation of heating, ventilation, and air-conditioning (HVAC) systems and the energy performance of buildings. The detailed occupancy information can improve HVAC operation and utilisation of building spaces. Strategies such as vision-based occupancy detection and recognition have recently garnered much interest. This study investigates the performance of a vision-based deep learning detection technique for enhancing building system operations and energy performances. The model used was the Faster RCNN with Inception V2. Two occupancy detection model configurations were developed, tested and evaluated. Both models were analysed based on the application of the detector within a selected case study building, along with the evaluation based on the different evaluation metrics. Results suggest that the occupancy detector (Model 1) provided an overall accuracy of 95.23% and an F1 score of 0.9756, while the occupancy activity detector (Model 2) provided an accuracy of 89.37% with an F1 score of 0.8298. Building Energy Simulation (BES) was used to evaluate and compare the impact of such an approach on the indoor occupancy heat gains. The study highlighted the potential of the detection approaches, but further development is necessary, including optimisation of the model, full integration with HVAC controls and further model training and field testing.\",\"PeriodicalId\":49671,\"journal\":{\"name\":\"Proceedings of the Institution of Civil Engineers-Engineering Sustainability\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2022-07-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institution of Civil Engineers-Engineering Sustainability\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1680/jensu.22.00013\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Civil Engineers-Engineering Sustainability","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1680/jensu.22.00013","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
Enhancing the detection performance of a vision-based occupancy detector for buildings
Occupant behaviour is one of the key parameters that significantly impact the operation of heating, ventilation, and air-conditioning (HVAC) systems and the energy performance of buildings. The detailed occupancy information can improve HVAC operation and utilisation of building spaces. Strategies such as vision-based occupancy detection and recognition have recently garnered much interest. This study investigates the performance of a vision-based deep learning detection technique for enhancing building system operations and energy performances. The model used was the Faster RCNN with Inception V2. Two occupancy detection model configurations were developed, tested and evaluated. Both models were analysed based on the application of the detector within a selected case study building, along with the evaluation based on the different evaluation metrics. Results suggest that the occupancy detector (Model 1) provided an overall accuracy of 95.23% and an F1 score of 0.9756, while the occupancy activity detector (Model 2) provided an accuracy of 89.37% with an F1 score of 0.8298. Building Energy Simulation (BES) was used to evaluate and compare the impact of such an approach on the indoor occupancy heat gains. The study highlighted the potential of the detection approaches, but further development is necessary, including optimisation of the model, full integration with HVAC controls and further model training and field testing.
期刊介绍:
Engineering Sustainability provides a forum for sharing the latest thinking from research and practice, and increasingly is presenting the ''how to'' of engineering a resilient future. The journal features refereed papers and shorter articles relating to the pursuit and implementation of sustainability principles through engineering planning, design and application. The tensions between and integration of social, economic and environmental considerations within such schemes are of particular relevance. Methodologies for assessing sustainability, policy issues, education and corporate responsibility will also be included. The aims will be met primarily by providing papers and briefing notes (including case histories and best practice guidance) of use to decision-makers, practitioners, researchers and students.