新旧合成酯浸渍湿纸板电性能的比较

K. Kierczyński, M. Zenker
{"title":"新旧合成酯浸渍湿纸板电性能的比较","authors":"K. Kierczyński, M. Zenker","doi":"10.1109/NAP51477.2020.9309647","DOIUrl":null,"url":null,"abstract":"The paper compares the electrical properties of moistened electrotechnical pressboard impregnated with factory-new and used synthetic ester MIDEL 7131. The tangent of the loss angle as the basic electrical properties of the electrotechnical pressboard impregnated with new and used synthetic ester was tested for four different moisture contents ranging from 0.5% by weight up to 6% by weight. The selected moisture contents correspond to the initial moisture contents of the brand new transformer units and of the transformers that are eligible for replacement. Thanks to the research, it was found out what influence the liquid we impregnate with has on the electrical properties of the moist cellulose insulation.","PeriodicalId":6770,"journal":{"name":"2020 IEEE 10th International Conference Nanomaterials: Applications & Properties (NAP)","volume":"20 1","pages":"02NEE10-1-02NEE10-4"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of Electrical Properties of Moistured Pressboard Impregnated with New and Used Synthetic Ester\",\"authors\":\"K. Kierczyński, M. Zenker\",\"doi\":\"10.1109/NAP51477.2020.9309647\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper compares the electrical properties of moistened electrotechnical pressboard impregnated with factory-new and used synthetic ester MIDEL 7131. The tangent of the loss angle as the basic electrical properties of the electrotechnical pressboard impregnated with new and used synthetic ester was tested for four different moisture contents ranging from 0.5% by weight up to 6% by weight. The selected moisture contents correspond to the initial moisture contents of the brand new transformer units and of the transformers that are eligible for replacement. Thanks to the research, it was found out what influence the liquid we impregnate with has on the electrical properties of the moist cellulose insulation.\",\"PeriodicalId\":6770,\"journal\":{\"name\":\"2020 IEEE 10th International Conference Nanomaterials: Applications & Properties (NAP)\",\"volume\":\"20 1\",\"pages\":\"02NEE10-1-02NEE10-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 10th International Conference Nanomaterials: Applications & Properties (NAP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAP51477.2020.9309647\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 10th International Conference Nanomaterials: Applications & Properties (NAP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAP51477.2020.9309647","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

比较了用新合成酯和旧合成酯midel7131浸渍的湿化电工板的电性能。对新合成酯和旧合成酯浸渍的电工板在0.5% ~ 6%的含水量范围内进行了损耗角切线作为基本电学性能的测试。所选的水分含量对应于全新变压器单元和符合更换条件的变压器的初始水分含量。通过研究,我们发现了浸渍的液体对湿性纤维素绝缘材料电性能的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of Electrical Properties of Moistured Pressboard Impregnated with New and Used Synthetic Ester
The paper compares the electrical properties of moistened electrotechnical pressboard impregnated with factory-new and used synthetic ester MIDEL 7131. The tangent of the loss angle as the basic electrical properties of the electrotechnical pressboard impregnated with new and used synthetic ester was tested for four different moisture contents ranging from 0.5% by weight up to 6% by weight. The selected moisture contents correspond to the initial moisture contents of the brand new transformer units and of the transformers that are eligible for replacement. Thanks to the research, it was found out what influence the liquid we impregnate with has on the electrical properties of the moist cellulose insulation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信