{"title":"评估患者安全问题的设备、用品和器械","authors":"R. Ratwani, Katharine T. Adams, Tracy C. Kim, Deanna-Nicole Busog, Jessica L. Howe, Rebecca Jones, Seth Krevat","doi":"10.33940/data/2023.3.2","DOIUrl":null,"url":null,"abstract":"Background: Medical equipment, supplies, and devices (ESD) serve a critical function in healthcare delivery and how they function can have patient safety consequences. ESD-related safety issues include malfunctions, physically missing ESDs, sterilization, and usability. Describing ESD-related safety issues from a human factors perspective that focuses on user interactions with ESDs can provide additional insights to address these issues. \n\nMethods: We manually reviewed ESD patient safety event reports submitted to the Pennsylvania Patient Safety Reporting System to identify ESD-related safety issues using a taxonomy that was informed by the Food and Drug Administration Manufacturer and User Facility Device Experience taxonomy. This taxonomy consisted of the following high-level categories: malfunctions, physically missing, sterilization, and usability. The type of ESD and associated components or ESD subtypes, event classification, and care area group were noted for each report. \n\nResults: Of the 450 reports reviewed, the most frequent ESD-related safety issue coded was malfunction (n=365 of 450, 81.1%) followed by sterilization (n=40 of 450, 8.9%), usability (n=36 of 450, 8.0%), and physically missing (n=9 of 450, 2.0%). Among the coded malfunctions, software/output problem (n=122 of 365, 33.4%) was the most frequent, followed by general malfunction (n=103 of 365, 28.2%); material integrity (n=72 of 365, 19.7%); and activation, positioning, or separation (n=68 of 365, 18.6%). The most frequent ESDs noted were infusion pump, instrument set, and intravenous, and the most frequent components/subtypes noted were alarm/alert, tubing, and tray. \n\nConclusion: ESD-related patient safety issues, especially malfunctions, impact patient care despite current policies and practices to address these issues. Healthcare facilities may be able to address some ESD-related patient safety issues during procurement through use of the accompanying procurement assessment tool.","PeriodicalId":46782,"journal":{"name":"Patient Safety in Surgery","volume":"41 1","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2023-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessing Equipment, Supplies, and Devices for Patient Safety Issues\",\"authors\":\"R. Ratwani, Katharine T. Adams, Tracy C. Kim, Deanna-Nicole Busog, Jessica L. Howe, Rebecca Jones, Seth Krevat\",\"doi\":\"10.33940/data/2023.3.2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Medical equipment, supplies, and devices (ESD) serve a critical function in healthcare delivery and how they function can have patient safety consequences. ESD-related safety issues include malfunctions, physically missing ESDs, sterilization, and usability. Describing ESD-related safety issues from a human factors perspective that focuses on user interactions with ESDs can provide additional insights to address these issues. \\n\\nMethods: We manually reviewed ESD patient safety event reports submitted to the Pennsylvania Patient Safety Reporting System to identify ESD-related safety issues using a taxonomy that was informed by the Food and Drug Administration Manufacturer and User Facility Device Experience taxonomy. This taxonomy consisted of the following high-level categories: malfunctions, physically missing, sterilization, and usability. The type of ESD and associated components or ESD subtypes, event classification, and care area group were noted for each report. \\n\\nResults: Of the 450 reports reviewed, the most frequent ESD-related safety issue coded was malfunction (n=365 of 450, 81.1%) followed by sterilization (n=40 of 450, 8.9%), usability (n=36 of 450, 8.0%), and physically missing (n=9 of 450, 2.0%). Among the coded malfunctions, software/output problem (n=122 of 365, 33.4%) was the most frequent, followed by general malfunction (n=103 of 365, 28.2%); material integrity (n=72 of 365, 19.7%); and activation, positioning, or separation (n=68 of 365, 18.6%). The most frequent ESDs noted were infusion pump, instrument set, and intravenous, and the most frequent components/subtypes noted were alarm/alert, tubing, and tray. \\n\\nConclusion: ESD-related patient safety issues, especially malfunctions, impact patient care despite current policies and practices to address these issues. Healthcare facilities may be able to address some ESD-related patient safety issues during procurement through use of the accompanying procurement assessment tool.\",\"PeriodicalId\":46782,\"journal\":{\"name\":\"Patient Safety in Surgery\",\"volume\":\"41 1\",\"pages\":\"\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Patient Safety in Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33940/data/2023.3.2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Patient Safety in Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33940/data/2023.3.2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
Assessing Equipment, Supplies, and Devices for Patient Safety Issues
Background: Medical equipment, supplies, and devices (ESD) serve a critical function in healthcare delivery and how they function can have patient safety consequences. ESD-related safety issues include malfunctions, physically missing ESDs, sterilization, and usability. Describing ESD-related safety issues from a human factors perspective that focuses on user interactions with ESDs can provide additional insights to address these issues.
Methods: We manually reviewed ESD patient safety event reports submitted to the Pennsylvania Patient Safety Reporting System to identify ESD-related safety issues using a taxonomy that was informed by the Food and Drug Administration Manufacturer and User Facility Device Experience taxonomy. This taxonomy consisted of the following high-level categories: malfunctions, physically missing, sterilization, and usability. The type of ESD and associated components or ESD subtypes, event classification, and care area group were noted for each report.
Results: Of the 450 reports reviewed, the most frequent ESD-related safety issue coded was malfunction (n=365 of 450, 81.1%) followed by sterilization (n=40 of 450, 8.9%), usability (n=36 of 450, 8.0%), and physically missing (n=9 of 450, 2.0%). Among the coded malfunctions, software/output problem (n=122 of 365, 33.4%) was the most frequent, followed by general malfunction (n=103 of 365, 28.2%); material integrity (n=72 of 365, 19.7%); and activation, positioning, or separation (n=68 of 365, 18.6%). The most frequent ESDs noted were infusion pump, instrument set, and intravenous, and the most frequent components/subtypes noted were alarm/alert, tubing, and tray.
Conclusion: ESD-related patient safety issues, especially malfunctions, impact patient care despite current policies and practices to address these issues. Healthcare facilities may be able to address some ESD-related patient safety issues during procurement through use of the accompanying procurement assessment tool.