间隔装置的最佳长度和宽度

P. Barry, C. O’Callaghan
{"title":"间隔装置的最佳长度和宽度","authors":"P. Barry, C. O’Callaghan","doi":"10.1211/146080800128735395","DOIUrl":null,"url":null,"abstract":"The aim of this study was to determine the delivery of two different drugs from spacer devices of different lengths and diameter. Spacer devices were prepared from lengths of plastic tubing of length 5, 10, 20, 50 and 100 cm, and diameter 30, 50 and 100 mm. Metered dose inhalers of sodium cromoglycate and budesonide were actuated into the spacers and drug output and particle size were measured using a glass multistage liquid impinger. To determine the effect of delay on the recovery of drug from the spacers, budesonide was actuated into spacers and output measured after a delay of 5, 10 or 20 s. For both drugs, increasing spacer length up to 20 cm increased drug recovery. There was no further increase or reduction with longer spacers. Increasing spacer diameter also increased drug recovery, although the increase was greater for sodium cromoglycate than budesonide. Budesonide delivery was greatest for spacers with a volume of 300 mL or greater, whereas maximum sodium cromoglycate delivery was from spacers with a volume of 1000 mL or greater. Drug half-life was also longer in larger spacers, being 6 s in a 10 cm length spacer (196 mL volume) and 15 s in a 20 cm length spacer (392 mL volume). The optimum spacer size was different for the two drugs. Sodium cromoglycate is best delivered from a larger spacer than budesonide. Conclusions from studies with one drug and spacer combination cannot be applied to another.","PeriodicalId":19946,"journal":{"name":"Pharmacy and Pharmacology Communications","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2000-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"The optimum length and width for a spacer device\",\"authors\":\"P. Barry, C. O’Callaghan\",\"doi\":\"10.1211/146080800128735395\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this study was to determine the delivery of two different drugs from spacer devices of different lengths and diameter. Spacer devices were prepared from lengths of plastic tubing of length 5, 10, 20, 50 and 100 cm, and diameter 30, 50 and 100 mm. Metered dose inhalers of sodium cromoglycate and budesonide were actuated into the spacers and drug output and particle size were measured using a glass multistage liquid impinger. To determine the effect of delay on the recovery of drug from the spacers, budesonide was actuated into spacers and output measured after a delay of 5, 10 or 20 s. For both drugs, increasing spacer length up to 20 cm increased drug recovery. There was no further increase or reduction with longer spacers. Increasing spacer diameter also increased drug recovery, although the increase was greater for sodium cromoglycate than budesonide. Budesonide delivery was greatest for spacers with a volume of 300 mL or greater, whereas maximum sodium cromoglycate delivery was from spacers with a volume of 1000 mL or greater. Drug half-life was also longer in larger spacers, being 6 s in a 10 cm length spacer (196 mL volume) and 15 s in a 20 cm length spacer (392 mL volume). The optimum spacer size was different for the two drugs. Sodium cromoglycate is best delivered from a larger spacer than budesonide. Conclusions from studies with one drug and spacer combination cannot be applied to another.\",\"PeriodicalId\":19946,\"journal\":{\"name\":\"Pharmacy and Pharmacology Communications\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmacy and Pharmacology Communications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1211/146080800128735395\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmacy and Pharmacology Communications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1211/146080800128735395","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本研究的目的是确定两种不同药物从不同长度和直径的间隔装置的递送。间隔装置由长度为5、10、20、50和100 cm,直径为30、50和100 mm的塑料管制成。将克莫糖酸钠和布地奈德的计量吸入器驱动到间隔器中,使用玻璃多级液体冲击器测量药物输出和颗粒大小。为了确定延迟对间隔剂中药物回收的影响,布地奈德被激活成间隔剂,并在延迟5、10或20秒后测量输出。对于这两种药物,增加间隔长度至20厘米可提高药物回收率。更长的间隔没有进一步的增加或减少。增加间隔直径也增加了药物回收率,尽管克莫甘酸钠比布地奈德的增加更大。布地奈德的最大递送量是300ml或更大的间隔剂,而最大递送量是1000ml或更大的间隔剂。在较大的间隔物中,药物半衰期也更长,在10 cm长的间隔物(体积为196 mL)中为6 s,在20 cm长的间隔物(体积为392 mL)中为15 s。两种药物的最佳间隔尺寸不同。从比布地奈德更大的间隔中输送克甘酸钠是最好的。一种药物和间隔剂联合研究的结论不能应用于另一种药物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The optimum length and width for a spacer device
The aim of this study was to determine the delivery of two different drugs from spacer devices of different lengths and diameter. Spacer devices were prepared from lengths of plastic tubing of length 5, 10, 20, 50 and 100 cm, and diameter 30, 50 and 100 mm. Metered dose inhalers of sodium cromoglycate and budesonide were actuated into the spacers and drug output and particle size were measured using a glass multistage liquid impinger. To determine the effect of delay on the recovery of drug from the spacers, budesonide was actuated into spacers and output measured after a delay of 5, 10 or 20 s. For both drugs, increasing spacer length up to 20 cm increased drug recovery. There was no further increase or reduction with longer spacers. Increasing spacer diameter also increased drug recovery, although the increase was greater for sodium cromoglycate than budesonide. Budesonide delivery was greatest for spacers with a volume of 300 mL or greater, whereas maximum sodium cromoglycate delivery was from spacers with a volume of 1000 mL or greater. Drug half-life was also longer in larger spacers, being 6 s in a 10 cm length spacer (196 mL volume) and 15 s in a 20 cm length spacer (392 mL volume). The optimum spacer size was different for the two drugs. Sodium cromoglycate is best delivered from a larger spacer than budesonide. Conclusions from studies with one drug and spacer combination cannot be applied to another.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信