基于svpwm的逆变器控制对基于dfig的wcs的LVRT增强

IF 0.6 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC
S. P, Dhandapani Samiappan, M. K, Nissyjoseph, Roshan M
{"title":"基于svpwm的逆变器控制对基于dfig的wcs的LVRT增强","authors":"S. P, Dhandapani Samiappan, M. K, Nissyjoseph, Roshan M","doi":"10.2174/2352096516666230606103013","DOIUrl":null,"url":null,"abstract":"\n\nAcross many countries, wind turbine generation systems (WTGS) have been established over the past few decades. In this paper, we augment the low voltage ride-through (LVRT) enrichment facility of driving a DFIG-based wind energy conversion system (WECS) using space vector pulse width modulation (SVPWM)-based inverter control. The proposed technique employs an SVPWM-based control algorithm to regulate the voltage and frequency of the output power during grid faults, thereby enhancing the WECS's ability to remain connected to the grid and provide power. The study focuses on decreasing transient current throughout the instant of fault. Modeling and control approaches were also discussed in this study. The performance of the proposed technique is evaluated using MATLAB/Simulink simulations, and the results demonstrate that the technique effectively improves the LVRT capability of the DFIG-based WECS.\n\n\n\nDue to the variation in wind speed, the power generated by wind turbines is inconsistent. The power generated and the losses in wind turbines change correspondingly with changes in wind speed. The only type of machine that can generate power at speeds below the fixed speed is the doubly-fed induction generator (DFIG). But DFIG is oversensitive to network faults, which makes the bidirectional converters and DC link capacitor fail due to high inrush current and over-voltage.\n\n\n\nThe converters connected to DFIG consist of an AC-to-DC converter, a boost converter, and a space vector pulse width modulation (SVPWM)-based DC-AC converter. The performance of the SVPWM controller is analyzed during symmetrical and unsymmetrical fault conditions.\n\n\n\nThe anticipated control provides adequate reactive power support to the network through the time of the fault and improves voltage and current waveform. The reactive power flow is also analyzed, and the effectiveness of the proposed controller is verified using MATLAB and Simulink.\n\n\n\nSVPWM (Space Vector Pulse Width Modulation)-based inverter control is an effective technique for wind energy conversion systems (WECS). The use of SVPWM can provide accurate and precise control of the AC voltage generated from the DC voltage source, resulting in improved system efficiency and reduced harmonic distortion in the output waveform.\nThe comparative analysis of THD suggests that SVPWM is a superior technique compared to other inverter control techniques such as sine-triangle pulse width modulation (SPWM) and carrier-based pulse width modulation (CPWM). SVPWM can help to reduce the distortion in the output waveform, leading to improved system efficiency, reduced wear on the system components, and overall better performance of the WECS.\nFurthermore, SVPWM offers several advantages over other inverter control techniques, including better utilization of DC voltage, improved voltage control, and better utilization of switching devices. These advantages make SVPWM a valuable tool for optimizing the operation of WECS and improving the reliability and performance of renewable energy systems. The value of THD for SVPWM inverter control in WECS is 1.53 under symmetrical fault and 1.34 for unsymmetrical fault, respectively.\nIn summary, the use of SVPWM-based inverter control for WECS is an effective way to improve the efficiency and performance of the system while reducing the distortion in the output waveform and providing adequate reactive power support. The advantages of SVPWM over other inverter control techniques make it a valuable tool for the development and optimization of renewable energy systems.\n","PeriodicalId":43275,"journal":{"name":"Recent Advances in Electrical & Electronic Engineering","volume":"81 1","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2023-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"LVRT Enhancement of DFIG-based WECS using SVPWM-based Inverter Control\",\"authors\":\"S. P, Dhandapani Samiappan, M. K, Nissyjoseph, Roshan M\",\"doi\":\"10.2174/2352096516666230606103013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n\\nAcross many countries, wind turbine generation systems (WTGS) have been established over the past few decades. In this paper, we augment the low voltage ride-through (LVRT) enrichment facility of driving a DFIG-based wind energy conversion system (WECS) using space vector pulse width modulation (SVPWM)-based inverter control. The proposed technique employs an SVPWM-based control algorithm to regulate the voltage and frequency of the output power during grid faults, thereby enhancing the WECS's ability to remain connected to the grid and provide power. The study focuses on decreasing transient current throughout the instant of fault. Modeling and control approaches were also discussed in this study. The performance of the proposed technique is evaluated using MATLAB/Simulink simulations, and the results demonstrate that the technique effectively improves the LVRT capability of the DFIG-based WECS.\\n\\n\\n\\nDue to the variation in wind speed, the power generated by wind turbines is inconsistent. The power generated and the losses in wind turbines change correspondingly with changes in wind speed. The only type of machine that can generate power at speeds below the fixed speed is the doubly-fed induction generator (DFIG). But DFIG is oversensitive to network faults, which makes the bidirectional converters and DC link capacitor fail due to high inrush current and over-voltage.\\n\\n\\n\\nThe converters connected to DFIG consist of an AC-to-DC converter, a boost converter, and a space vector pulse width modulation (SVPWM)-based DC-AC converter. The performance of the SVPWM controller is analyzed during symmetrical and unsymmetrical fault conditions.\\n\\n\\n\\nThe anticipated control provides adequate reactive power support to the network through the time of the fault and improves voltage and current waveform. The reactive power flow is also analyzed, and the effectiveness of the proposed controller is verified using MATLAB and Simulink.\\n\\n\\n\\nSVPWM (Space Vector Pulse Width Modulation)-based inverter control is an effective technique for wind energy conversion systems (WECS). The use of SVPWM can provide accurate and precise control of the AC voltage generated from the DC voltage source, resulting in improved system efficiency and reduced harmonic distortion in the output waveform.\\nThe comparative analysis of THD suggests that SVPWM is a superior technique compared to other inverter control techniques such as sine-triangle pulse width modulation (SPWM) and carrier-based pulse width modulation (CPWM). SVPWM can help to reduce the distortion in the output waveform, leading to improved system efficiency, reduced wear on the system components, and overall better performance of the WECS.\\nFurthermore, SVPWM offers several advantages over other inverter control techniques, including better utilization of DC voltage, improved voltage control, and better utilization of switching devices. These advantages make SVPWM a valuable tool for optimizing the operation of WECS and improving the reliability and performance of renewable energy systems. The value of THD for SVPWM inverter control in WECS is 1.53 under symmetrical fault and 1.34 for unsymmetrical fault, respectively.\\nIn summary, the use of SVPWM-based inverter control for WECS is an effective way to improve the efficiency and performance of the system while reducing the distortion in the output waveform and providing adequate reactive power support. The advantages of SVPWM over other inverter control techniques make it a valuable tool for the development and optimization of renewable energy systems.\\n\",\"PeriodicalId\":43275,\"journal\":{\"name\":\"Recent Advances in Electrical & Electronic Engineering\",\"volume\":\"81 1\",\"pages\":\"\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-06-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Recent Advances in Electrical & Electronic Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/2352096516666230606103013\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Recent Advances in Electrical & Electronic Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/2352096516666230606103013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

在过去的几十年里,许多国家都建立了风力发电系统(WTGS)。在本文中,我们利用基于空间矢量脉宽调制(SVPWM)的逆变器控制来增强驱动基于dfig的风能转换系统(WECS)的低压穿越(LVRT)增强设施。该技术采用基于svpwm的控制算法,在电网故障时调节输出功率的电压和频率,从而增强WECS保持与电网连接并提供电力的能力。研究的重点是降低故障瞬间的暂态电流。本文还讨论了建模和控制方法。通过MATLAB/Simulink仿真对该技术的性能进行了评估,结果表明该技术有效地提高了基于dfig的wcs的LVRT能力。由于风速的变化,风力发电机产生的功率是不一致的。风力机的发电量和损耗随风速的变化而相应变化。唯一一种能够以低于固定速度的速度发电的机器是双馈感应发电机(DFIG)。但DFIG对网络故障过于敏感,导致双向变流器和直流链路电容因浪涌电流过大和过电压过高而失效。连接到DFIG的转换器包括一个ac - dc转换器、一个升压转换器和一个基于空间矢量脉宽调制(SVPWM)的DC-AC转换器。分析了SVPWM控制器在对称和非对称故障条件下的性能。预期控制可以在故障发生时为电网提供足够的无功支持,改善电压和电流波形。分析了无功潮流,并利用MATLAB和Simulink验证了所提控制器的有效性。基于空间矢量脉宽调制(SVPWM)的逆变器控制是一种有效的风能转换系统控制技术。使用SVPWM可以对直流电压源产生的交流电压进行精确的控制,从而提高系统效率,减少输出波形中的谐波失真。THD的对比分析表明,与正弦三角形脉宽调制(SPWM)和基于载波的脉宽调制(CPWM)等其他逆变器控制技术相比,SVPWM是一种优越的技术。SVPWM可以帮助减少输出波形的失真,从而提高系统效率,减少系统组件的磨损,并提高wcs的整体性能。此外,与其他逆变器控制技术相比,SVPWM提供了几个优势,包括更好地利用直流电压,改进电压控制,更好地利用开关器件。这些优点使SVPWM成为优化WECS运行和提高可再生能源系统可靠性和性能的宝贵工具。wcs中SVPWM逆变器控制的THD在对称故障下为1.53,在不对称故障下为1.34。综上所述,使用基于svpwm的逆变器控制WECS是提高系统效率和性能的有效途径,同时减少输出波形的失真,并提供足够的无功支持。与其他逆变器控制技术相比,SVPWM的优势使其成为可再生能源系统开发和优化的宝贵工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
LVRT Enhancement of DFIG-based WECS using SVPWM-based Inverter Control
Across many countries, wind turbine generation systems (WTGS) have been established over the past few decades. In this paper, we augment the low voltage ride-through (LVRT) enrichment facility of driving a DFIG-based wind energy conversion system (WECS) using space vector pulse width modulation (SVPWM)-based inverter control. The proposed technique employs an SVPWM-based control algorithm to regulate the voltage and frequency of the output power during grid faults, thereby enhancing the WECS's ability to remain connected to the grid and provide power. The study focuses on decreasing transient current throughout the instant of fault. Modeling and control approaches were also discussed in this study. The performance of the proposed technique is evaluated using MATLAB/Simulink simulations, and the results demonstrate that the technique effectively improves the LVRT capability of the DFIG-based WECS. Due to the variation in wind speed, the power generated by wind turbines is inconsistent. The power generated and the losses in wind turbines change correspondingly with changes in wind speed. The only type of machine that can generate power at speeds below the fixed speed is the doubly-fed induction generator (DFIG). But DFIG is oversensitive to network faults, which makes the bidirectional converters and DC link capacitor fail due to high inrush current and over-voltage. The converters connected to DFIG consist of an AC-to-DC converter, a boost converter, and a space vector pulse width modulation (SVPWM)-based DC-AC converter. The performance of the SVPWM controller is analyzed during symmetrical and unsymmetrical fault conditions. The anticipated control provides adequate reactive power support to the network through the time of the fault and improves voltage and current waveform. The reactive power flow is also analyzed, and the effectiveness of the proposed controller is verified using MATLAB and Simulink. SVPWM (Space Vector Pulse Width Modulation)-based inverter control is an effective technique for wind energy conversion systems (WECS). The use of SVPWM can provide accurate and precise control of the AC voltage generated from the DC voltage source, resulting in improved system efficiency and reduced harmonic distortion in the output waveform. The comparative analysis of THD suggests that SVPWM is a superior technique compared to other inverter control techniques such as sine-triangle pulse width modulation (SPWM) and carrier-based pulse width modulation (CPWM). SVPWM can help to reduce the distortion in the output waveform, leading to improved system efficiency, reduced wear on the system components, and overall better performance of the WECS. Furthermore, SVPWM offers several advantages over other inverter control techniques, including better utilization of DC voltage, improved voltage control, and better utilization of switching devices. These advantages make SVPWM a valuable tool for optimizing the operation of WECS and improving the reliability and performance of renewable energy systems. The value of THD for SVPWM inverter control in WECS is 1.53 under symmetrical fault and 1.34 for unsymmetrical fault, respectively. In summary, the use of SVPWM-based inverter control for WECS is an effective way to improve the efficiency and performance of the system while reducing the distortion in the output waveform and providing adequate reactive power support. The advantages of SVPWM over other inverter control techniques make it a valuable tool for the development and optimization of renewable energy systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Recent Advances in Electrical & Electronic Engineering
Recent Advances in Electrical & Electronic Engineering ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
1.70
自引率
16.70%
发文量
101
期刊介绍: Recent Advances in Electrical & Electronic Engineering publishes full-length/mini reviews and research articles, guest edited thematic issues on electrical and electronic engineering and applications. The journal also covers research in fast emerging applications of electrical power supply, electrical systems, power transmission, electromagnetism, motor control process and technologies involved and related to electrical and electronic engineering. The journal is essential reading for all researchers in electrical and electronic engineering science.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信