基于仿真模型的电压谐波对污染绝缘子状态评估的影响

A. Banik, S. Nielsen, G. Nourbakhsh
{"title":"基于仿真模型的电压谐波对污染绝缘子状态评估的影响","authors":"A. Banik, S. Nielsen, G. Nourbakhsh","doi":"10.1109/CMD.2018.8535674","DOIUrl":null,"url":null,"abstract":"The condition assessment of outdoor high voltage insulators is of prime importance to power utilities. There are numerous indicators used for inferring the surface condition of an insulator based on an analysis of measured leakage current. To date, the assumption by most researchers has been that the supply voltage subject on insulators is sinusoidal with little or no harmonic induced distortion. However, in real-life due to ever increasing trend of using power electronics devices in power network, significant amount of harmonic distortion is common and insulators in the power system are directly subjected to this distortion. Therefore, the effectiveness of all those present indices under purely sinusoidal voltage will become questionable in presence of distorted supply voltage. This work aims to investigate the effect of voltage harmonic contents on the measured leakage current of polluted insulators via a developed simulation model. In this paper, by considering the practical supply voltage distortion, authors have shown the major drawback of present indices based condition assessment techniques. Authors have also tried to provide an optimal solution by proposing a Crest Factor (CF) based distinctive index to overcome the problem, based on simulation results.","PeriodicalId":6529,"journal":{"name":"2018 Condition Monitoring and Diagnosis (CMD)","volume":"234 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Impact of Voltage Harmonics on Condition Assessment of Polluted Insulator through a Simulation Model\",\"authors\":\"A. Banik, S. Nielsen, G. Nourbakhsh\",\"doi\":\"10.1109/CMD.2018.8535674\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The condition assessment of outdoor high voltage insulators is of prime importance to power utilities. There are numerous indicators used for inferring the surface condition of an insulator based on an analysis of measured leakage current. To date, the assumption by most researchers has been that the supply voltage subject on insulators is sinusoidal with little or no harmonic induced distortion. However, in real-life due to ever increasing trend of using power electronics devices in power network, significant amount of harmonic distortion is common and insulators in the power system are directly subjected to this distortion. Therefore, the effectiveness of all those present indices under purely sinusoidal voltage will become questionable in presence of distorted supply voltage. This work aims to investigate the effect of voltage harmonic contents on the measured leakage current of polluted insulators via a developed simulation model. In this paper, by considering the practical supply voltage distortion, authors have shown the major drawback of present indices based condition assessment techniques. Authors have also tried to provide an optimal solution by proposing a Crest Factor (CF) based distinctive index to overcome the problem, based on simulation results.\",\"PeriodicalId\":6529,\"journal\":{\"name\":\"2018 Condition Monitoring and Diagnosis (CMD)\",\"volume\":\"234 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 Condition Monitoring and Diagnosis (CMD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CMD.2018.8535674\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Condition Monitoring and Diagnosis (CMD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CMD.2018.8535674","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

室外高压绝缘子的状态评估是电力公司工作的重中之重。根据对测量的泄漏电流的分析,有许多指标用于推断绝缘子的表面状况。迄今为止,大多数研究人员都假设绝缘子上的电源电压是正弦电压,很少或没有谐波畸变。然而,在现实生活中,由于电力电子设备在电网中的应用越来越多,导致了大量的谐波畸变,而电力系统中的绝缘子直接受到谐波畸变的影响。因此,在电源电压失真的情况下,所有这些指标在纯正弦电压下的有效性都将受到质疑。本文旨在通过建立的仿真模型,研究电压谐波含量对污染绝缘子泄漏电流测量的影响。本文从实际供电电压畸变出发,指出了目前基于指标的状态评估技术的主要缺陷。作者还尝试在仿真结果的基础上,提出一种基于波峰因子(Crest Factor, CF)的特征指数来克服这一问题,从而提供一个最优的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of Voltage Harmonics on Condition Assessment of Polluted Insulator through a Simulation Model
The condition assessment of outdoor high voltage insulators is of prime importance to power utilities. There are numerous indicators used for inferring the surface condition of an insulator based on an analysis of measured leakage current. To date, the assumption by most researchers has been that the supply voltage subject on insulators is sinusoidal with little or no harmonic induced distortion. However, in real-life due to ever increasing trend of using power electronics devices in power network, significant amount of harmonic distortion is common and insulators in the power system are directly subjected to this distortion. Therefore, the effectiveness of all those present indices under purely sinusoidal voltage will become questionable in presence of distorted supply voltage. This work aims to investigate the effect of voltage harmonic contents on the measured leakage current of polluted insulators via a developed simulation model. In this paper, by considering the practical supply voltage distortion, authors have shown the major drawback of present indices based condition assessment techniques. Authors have also tried to provide an optimal solution by proposing a Crest Factor (CF) based distinctive index to overcome the problem, based on simulation results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信