{"title":"GIT8导通和POS开通时的电流分布","authors":"A. Kim, B. Kovalchuk, V. Kokshenev, N. Kurmaev, S. Loginov, F. I. Fursov, V. P. Jakovlev","doi":"10.1109/PPC.1995.596484","DOIUrl":null,"url":null,"abstract":"The concept of the multi module pulsed power system using the inductive energy storage (IES) technology may be developed on a base of one of two possible plasma opening switch (POS) designs. First is the multi POS design with the number of the switches being equal to the number of the modules. The main advantages of this design are the possibility to perform the full scale investigation of the single module prototype including the POS before the total system will be built, and the possibility to increase the power of the system by adding some number of the well known elements. The main disadvantage of the multi POS design seems to be the jitter in the switch openings-the problem which is not solved at present. The second, single POS design, presumes one POS switching the energy from all the modules into the load. The main advantage of the design is the absence of the POS synchronization problem. In the same time the single POS design requires building of the total system before the POS could be tested resulting in a risk of worse opening or some other problems which may appear at increased POS current level. The GIT4-GIT8 facilities at HCEI represent a test bed allowing investigation of the single POS design at successively increasing POS current (2.5-5 MA). The goal of the experiments described was to clear the current distribution in the switch region on GIT8 and to determine possible restrictions which could limit the application of the given single POS design.","PeriodicalId":11163,"journal":{"name":"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1995-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Current distribution during conduction and POS opening on GIT8\",\"authors\":\"A. Kim, B. Kovalchuk, V. Kokshenev, N. Kurmaev, S. Loginov, F. I. Fursov, V. P. Jakovlev\",\"doi\":\"10.1109/PPC.1995.596484\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The concept of the multi module pulsed power system using the inductive energy storage (IES) technology may be developed on a base of one of two possible plasma opening switch (POS) designs. First is the multi POS design with the number of the switches being equal to the number of the modules. The main advantages of this design are the possibility to perform the full scale investigation of the single module prototype including the POS before the total system will be built, and the possibility to increase the power of the system by adding some number of the well known elements. The main disadvantage of the multi POS design seems to be the jitter in the switch openings-the problem which is not solved at present. The second, single POS design, presumes one POS switching the energy from all the modules into the load. The main advantage of the design is the absence of the POS synchronization problem. In the same time the single POS design requires building of the total system before the POS could be tested resulting in a risk of worse opening or some other problems which may appear at increased POS current level. The GIT4-GIT8 facilities at HCEI represent a test bed allowing investigation of the single POS design at successively increasing POS current (2.5-5 MA). The goal of the experiments described was to clear the current distribution in the switch region on GIT8 and to determine possible restrictions which could limit the application of the given single POS design.\",\"PeriodicalId\":11163,\"journal\":{\"name\":\"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PPC.1995.596484\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.1995.596484","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

采用电感储能技术的多模块脉冲电源系统的概念可以在两种可能的等离子体开断开关(POS)设计的基础上发展。首先是多POS设计,交换机的数量等于模块的数量。本设计的主要优点是可以在构建整个系统之前对包括POS在内的单模块原型进行全尺寸调查,并且可以通过添加一些已知元素来增加系统的功率。多POS设计的主要缺点似乎是开关开度的抖动,这是目前尚未解决的问题。第二种是单POS设计,假设一个POS将所有模块的能量转换为负载。该设计的主要优点是没有POS同步问题。同时,单个POS机的设计需要在POS机测试之前建立整个系统,这导致了在POS机电流水平增加时可能出现的开度差或其他一些问题的风险。HCEI的GIT4-GIT8设备代表了一个测试平台,允许在连续增加POS电流(2.5-5 MA)的情况下研究单个POS设计。所述实验的目标是清除GIT8上开关区域的电流分布,并确定可能限制给定单一POS设计应用的可能限制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Current distribution during conduction and POS opening on GIT8
The concept of the multi module pulsed power system using the inductive energy storage (IES) technology may be developed on a base of one of two possible plasma opening switch (POS) designs. First is the multi POS design with the number of the switches being equal to the number of the modules. The main advantages of this design are the possibility to perform the full scale investigation of the single module prototype including the POS before the total system will be built, and the possibility to increase the power of the system by adding some number of the well known elements. The main disadvantage of the multi POS design seems to be the jitter in the switch openings-the problem which is not solved at present. The second, single POS design, presumes one POS switching the energy from all the modules into the load. The main advantage of the design is the absence of the POS synchronization problem. In the same time the single POS design requires building of the total system before the POS could be tested resulting in a risk of worse opening or some other problems which may appear at increased POS current level. The GIT4-GIT8 facilities at HCEI represent a test bed allowing investigation of the single POS design at successively increasing POS current (2.5-5 MA). The goal of the experiments described was to clear the current distribution in the switch region on GIT8 and to determine possible restrictions which could limit the application of the given single POS design.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信