在LabView中应用模糊逻辑开发光伏系统铅酸蓄电池组电量监测

Leonardro A. Venancio, Armyn C. Sy, R. Bedruz, E. Dadios
{"title":"在LabView中应用模糊逻辑开发光伏系统铅酸蓄电池组电量监测","authors":"Leonardro A. Venancio, Armyn C. Sy, R. Bedruz, E. Dadios","doi":"10.1109/HNICEM48295.2019.9073361","DOIUrl":null,"url":null,"abstract":"This paper presents a charge level monitoring system for lead acid battery bank in Solar Panel setup. The research implements the approximate linear relationship between the charge level and the current-voltage for lead acid batteries. Prediction method utilizes is the objective fuzzy logic approach. Both the interphase of the instrument and the fuzzy system together with the fuzzy rule system were created using LabView. Dataset used is based on an actual 12-hour data gathering of charging cycle and current-voltage readings. Simulation results show that the developed system generated correctly the charge level of the battery using only the instantaneous voltage and current readings from the sensors.","PeriodicalId":6733,"journal":{"name":"2019 IEEE 11th International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment, and Management ( HNICEM )","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of Charge Level Monitoring of Lead-Acid Battery Bank for PV System using Fuzzy Logic in LabView\",\"authors\":\"Leonardro A. Venancio, Armyn C. Sy, R. Bedruz, E. Dadios\",\"doi\":\"10.1109/HNICEM48295.2019.9073361\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a charge level monitoring system for lead acid battery bank in Solar Panel setup. The research implements the approximate linear relationship between the charge level and the current-voltage for lead acid batteries. Prediction method utilizes is the objective fuzzy logic approach. Both the interphase of the instrument and the fuzzy system together with the fuzzy rule system were created using LabView. Dataset used is based on an actual 12-hour data gathering of charging cycle and current-voltage readings. Simulation results show that the developed system generated correctly the charge level of the battery using only the instantaneous voltage and current readings from the sensors.\",\"PeriodicalId\":6733,\"journal\":{\"name\":\"2019 IEEE 11th International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment, and Management ( HNICEM )\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE 11th International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment, and Management ( HNICEM )\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HNICEM48295.2019.9073361\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 11th International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment, and Management ( HNICEM )","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HNICEM48295.2019.9073361","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了一种太阳能电池板安装中铅酸蓄电池组的电量监测系统。研究实现了铅酸电池的充电电平与电流电压之间的近似线性关系。预测方法采用的是客观模糊逻辑方法。利用LabView建立了仪器的界面、模糊系统和模糊规则系统。使用的数据集是基于实际的12小时充电周期和电流-电压读数的数据收集。仿真结果表明,所开发的系统仅使用传感器的瞬时电压和电流读数就能正确地生成电池的充电水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of Charge Level Monitoring of Lead-Acid Battery Bank for PV System using Fuzzy Logic in LabView
This paper presents a charge level monitoring system for lead acid battery bank in Solar Panel setup. The research implements the approximate linear relationship between the charge level and the current-voltage for lead acid batteries. Prediction method utilizes is the objective fuzzy logic approach. Both the interphase of the instrument and the fuzzy system together with the fuzzy rule system were created using LabView. Dataset used is based on an actual 12-hour data gathering of charging cycle and current-voltage readings. Simulation results show that the developed system generated correctly the charge level of the battery using only the instantaneous voltage and current readings from the sensors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信