OpenForce MR:一种低成本的开源MR兼容力传感器

IF 0.9 4区 医学 Q4 CHEMISTRY, PHYSICAL
Francesco Santini, Oliver Bieri, Xeni Deligianni
{"title":"OpenForce MR:一种低成本的开源MR兼容力传感器","authors":"Francesco Santini,&nbsp;Oliver Bieri,&nbsp;Xeni Deligianni","doi":"10.1002/cmr.b.21404","DOIUrl":null,"url":null,"abstract":"<p>Measuring the force exerted by muscles during dynamic MR acquisition (either imaging or spectroscopy) provides important information for the standardization of the exercise performed in the scanner and is therefore important for reproducible results in musculoskeletal imaging. However, existing commercial solutions for such measurements are often very expensive and impractical. In this work, a novel, open-source, versatile force sensor made of non-magnetic, off-the-shelf components is presented. The sensor is based on four aluminum Wheatstone bridge load cells enclosed in a custom-built aluminum frame. These cells are connected to an Arduino microcontroller for data acquisition and serial communication with a host computer, on which a dedicated program visualizes and logs the recorded force in real time. All components were chosen to be compatible with the MR environment, commercially available, and low cost. The sensor was calibrated with a commercial dynamometer and subsequently tested in multiple MR acquisition scenarios (static morphological imaging, cine imaging during contraction, velocity-encoded imaging). The sensor correctly recorded data during all tested sequences, without cross-interference between the MR and the force acquisitions. Minor susceptibility artifacts are visible in the immediate vicinity of the sensor, but they did not impair the evaluation of the muscle of interest. In conclusion, the development of a low-cost, MR-compatible force sensor is feasible, and its usage does not interfere with MR acquisition. The full specifications of the sensor, including hardware design, firmware and host software are publicly released as open-source for the potential benefit of the whole community.</p>","PeriodicalId":50623,"journal":{"name":"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering","volume":"48B 4","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2019-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/cmr.b.21404","citationCount":"4","resultStr":"{\"title\":\"OpenForce MR: A low-cost open-source MR-compatible force sensor\",\"authors\":\"Francesco Santini,&nbsp;Oliver Bieri,&nbsp;Xeni Deligianni\",\"doi\":\"10.1002/cmr.b.21404\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Measuring the force exerted by muscles during dynamic MR acquisition (either imaging or spectroscopy) provides important information for the standardization of the exercise performed in the scanner and is therefore important for reproducible results in musculoskeletal imaging. However, existing commercial solutions for such measurements are often very expensive and impractical. In this work, a novel, open-source, versatile force sensor made of non-magnetic, off-the-shelf components is presented. The sensor is based on four aluminum Wheatstone bridge load cells enclosed in a custom-built aluminum frame. These cells are connected to an Arduino microcontroller for data acquisition and serial communication with a host computer, on which a dedicated program visualizes and logs the recorded force in real time. All components were chosen to be compatible with the MR environment, commercially available, and low cost. The sensor was calibrated with a commercial dynamometer and subsequently tested in multiple MR acquisition scenarios (static morphological imaging, cine imaging during contraction, velocity-encoded imaging). The sensor correctly recorded data during all tested sequences, without cross-interference between the MR and the force acquisitions. Minor susceptibility artifacts are visible in the immediate vicinity of the sensor, but they did not impair the evaluation of the muscle of interest. In conclusion, the development of a low-cost, MR-compatible force sensor is feasible, and its usage does not interfere with MR acquisition. The full specifications of the sensor, including hardware design, firmware and host software are publicly released as open-source for the potential benefit of the whole community.</p>\",\"PeriodicalId\":50623,\"journal\":{\"name\":\"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering\",\"volume\":\"48B 4\",\"pages\":\"\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2019-02-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/cmr.b.21404\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/cmr.b.21404\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cmr.b.21404","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 4

摘要

在动态MR采集(成像或光谱)过程中测量肌肉施加的力为扫描仪中执行的运动的标准化提供了重要信息,因此对于肌肉骨骼成像的可重复性结果非常重要。然而,这种测量的现有商业解决方案通常非常昂贵且不切实际。在这项工作中,提出了一种新的、开源的、通用的力传感器,由非磁性、现成的组件制成。该传感器是基于四个铝制惠斯通桥式称重传感器封闭在一个定制的铝制框架。这些单元连接到Arduino微控制器进行数据采集,并与主机进行串行通信,在主机上专用程序实时可视化并记录记录的力。所有组件都选择了与MR环境兼容、可商用且成本低的组件。该传感器使用商用测力计进行校准,随后在多种磁共振采集场景(静态形态学成像、收缩期间的电影成像、速度编码成像)中进行测试。传感器在所有测试序列中正确记录数据,在MR和力获取之间没有交叉干扰。在传感器附近可以看到轻微的敏感性伪影,但它们不会损害感兴趣肌肉的评估。总之,开发一种低成本、与磁共振兼容的力传感器是可行的,而且它的使用不会干扰磁共振采集。为了整个社区的潜在利益,传感器的完整规格,包括硬件设计、固件和主机软件都作为开源公开发布。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
OpenForce MR: A low-cost open-source MR-compatible force sensor

Measuring the force exerted by muscles during dynamic MR acquisition (either imaging or spectroscopy) provides important information for the standardization of the exercise performed in the scanner and is therefore important for reproducible results in musculoskeletal imaging. However, existing commercial solutions for such measurements are often very expensive and impractical. In this work, a novel, open-source, versatile force sensor made of non-magnetic, off-the-shelf components is presented. The sensor is based on four aluminum Wheatstone bridge load cells enclosed in a custom-built aluminum frame. These cells are connected to an Arduino microcontroller for data acquisition and serial communication with a host computer, on which a dedicated program visualizes and logs the recorded force in real time. All components were chosen to be compatible with the MR environment, commercially available, and low cost. The sensor was calibrated with a commercial dynamometer and subsequently tested in multiple MR acquisition scenarios (static morphological imaging, cine imaging during contraction, velocity-encoded imaging). The sensor correctly recorded data during all tested sequences, without cross-interference between the MR and the force acquisitions. Minor susceptibility artifacts are visible in the immediate vicinity of the sensor, but they did not impair the evaluation of the muscle of interest. In conclusion, the development of a low-cost, MR-compatible force sensor is feasible, and its usage does not interfere with MR acquisition. The full specifications of the sensor, including hardware design, firmware and host software are publicly released as open-source for the potential benefit of the whole community.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.60
自引率
0.00%
发文量
3
审稿时长
>12 weeks
期刊介绍: Concepts in Magnetic Resonance Part B brings together engineers and physicists involved in the design and development of hardware and software employed in magnetic resonance techniques. The journal welcomes contributions predominantly from the fields of magnetic resonance imaging (MRI), nuclear magnetic resonance (NMR), and electron paramagnetic resonance (EPR), but also encourages submissions relating to less common magnetic resonance imaging and analytical methods. Contributors come from both academia and industry, to report the latest advancements in the development of instrumentation and computer programming to underpin medical, non-medical, and analytical magnetic resonance techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信