{"title":"坐标旋转下高帧率成像系统的2C-5简化","authors":"Jian-yu Lu, S. Kwon","doi":"10.1109/ULTSYM.2007.22","DOIUrl":null,"url":null,"abstract":"A method to greatly simplify the high-frame-rate (HFR) imaging system using a rotation of coordinates in image reconstruction was developed. A theory of Fourier image reconstruction was also developed and both in vitro (on an ATS539 tissue-mimicking phantom) and in vivo (on a human heart) experiments were performed to verify the theory.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"27 1","pages":"33-36"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"2C-5 Simplification of High Frame Rate Imaging System with Coordinate Rotation\",\"authors\":\"Jian-yu Lu, S. Kwon\",\"doi\":\"10.1109/ULTSYM.2007.22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method to greatly simplify the high-frame-rate (HFR) imaging system using a rotation of coordinates in image reconstruction was developed. A theory of Fourier image reconstruction was also developed and both in vitro (on an ATS539 tissue-mimicking phantom) and in vivo (on a human heart) experiments were performed to verify the theory.\",\"PeriodicalId\":6355,\"journal\":{\"name\":\"2007 IEEE Ultrasonics Symposium Proceedings\",\"volume\":\"27 1\",\"pages\":\"33-36\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Ultrasonics Symposium Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2007.22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Ultrasonics Symposium Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2007.22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
2C-5 Simplification of High Frame Rate Imaging System with Coordinate Rotation
A method to greatly simplify the high-frame-rate (HFR) imaging system using a rotation of coordinates in image reconstruction was developed. A theory of Fourier image reconstruction was also developed and both in vitro (on an ATS539 tissue-mimicking phantom) and in vivo (on a human heart) experiments were performed to verify the theory.