在高达900°C的退火温度下,Ni/氢气端接金刚石可靠的欧姆接触特性

Xiaolu Yuan, Jiangwei Liu, Jinlong Liu, Junjun Wei, B. Da, Chengming Li, Y. Koide
{"title":"在高达900°C的退火温度下,Ni/氢气端接金刚石可靠的欧姆接触特性","authors":"Xiaolu Yuan, Jiangwei Liu, Jinlong Liu, Junjun Wei, B. Da, Chengming Li, Y. Koide","doi":"10.3390/COATINGS11040470","DOIUrl":null,"url":null,"abstract":"Ohmic contact with high thermal stability is essential to promote hydrogen-terminated diamond (H-diamond) electronic devices for high-temperature applications. Here, the ohmic contact characteristics of Ni/H-diamond at annealing temperatures up to 900 °C are investigated. The measured current–voltage curves and deduced specific contact resistance (ρC) are used to evaluate the quality of the contact properties. Schottky contacts are formed for the as-received and 300 °C-annealed Ni/H-diamonds. When the annealing temperature is increased to 500 °C, the ohmic contact properties are formed with the ρC of 1.5 × 10−3 Ω·cm2 for the Ni/H-diamond. As the annealing temperature rises to 900 °C, the ρC is determined to be as low as 6.0 × 10−5 Ω·cm2. It is believed that the formation of Ni-related carbides at the Ni/H-diamond interface promotes the decrease in ρC. The Ni metal is extremely promising to be used as the ohmic contact electrode for the H-diamond-based electronic devices at temperature up to 900 °C.","PeriodicalId":22482,"journal":{"name":"THE Coatings","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliable Ohmic Contact Properties for Ni/Hydrogen-Terminated Diamond at Annealing Temperature up to 900 °C\",\"authors\":\"Xiaolu Yuan, Jiangwei Liu, Jinlong Liu, Junjun Wei, B. Da, Chengming Li, Y. Koide\",\"doi\":\"10.3390/COATINGS11040470\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ohmic contact with high thermal stability is essential to promote hydrogen-terminated diamond (H-diamond) electronic devices for high-temperature applications. Here, the ohmic contact characteristics of Ni/H-diamond at annealing temperatures up to 900 °C are investigated. The measured current–voltage curves and deduced specific contact resistance (ρC) are used to evaluate the quality of the contact properties. Schottky contacts are formed for the as-received and 300 °C-annealed Ni/H-diamonds. When the annealing temperature is increased to 500 °C, the ohmic contact properties are formed with the ρC of 1.5 × 10−3 Ω·cm2 for the Ni/H-diamond. As the annealing temperature rises to 900 °C, the ρC is determined to be as low as 6.0 × 10−5 Ω·cm2. It is believed that the formation of Ni-related carbides at the Ni/H-diamond interface promotes the decrease in ρC. The Ni metal is extremely promising to be used as the ohmic contact electrode for the H-diamond-based electronic devices at temperature up to 900 °C.\",\"PeriodicalId\":22482,\"journal\":{\"name\":\"THE Coatings\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"THE Coatings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/COATINGS11040470\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"THE Coatings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/COATINGS11040470","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

具有高热稳定性的欧姆接触对于促进高温应用的端氢金刚石(H-diamond)电子器件至关重要。本文研究了Ni/ h -金刚石在900℃退火温度下的欧姆接触特性。利用实测的电流-电压曲线和推导出的接触电阻ρC来评价接触性能的好坏。接收态和300℃退火的Ni/ h -金刚石形成肖特基触点。当退火温度提高到500℃时,Ni/ h -金刚石形成欧姆接触性质,ρC为1.5 × 10−3 Ω·cm2。当退火温度升至900℃时,ρC可低至6.0 × 10−5 Ω·cm2。认为Ni/ h -金刚石界面处Ni相关碳化物的形成促进了ρC的降低。镍金属极有希望在高达900°C的温度下用作h -金刚石基电子器件的欧姆接触电极。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reliable Ohmic Contact Properties for Ni/Hydrogen-Terminated Diamond at Annealing Temperature up to 900 °C
Ohmic contact with high thermal stability is essential to promote hydrogen-terminated diamond (H-diamond) electronic devices for high-temperature applications. Here, the ohmic contact characteristics of Ni/H-diamond at annealing temperatures up to 900 °C are investigated. The measured current–voltage curves and deduced specific contact resistance (ρC) are used to evaluate the quality of the contact properties. Schottky contacts are formed for the as-received and 300 °C-annealed Ni/H-diamonds. When the annealing temperature is increased to 500 °C, the ohmic contact properties are formed with the ρC of 1.5 × 10−3 Ω·cm2 for the Ni/H-diamond. As the annealing temperature rises to 900 °C, the ρC is determined to be as low as 6.0 × 10−5 Ω·cm2. It is believed that the formation of Ni-related carbides at the Ni/H-diamond interface promotes the decrease in ρC. The Ni metal is extremely promising to be used as the ohmic contact electrode for the H-diamond-based electronic devices at temperature up to 900 °C.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信