S. Kumara, T. Hammarström, Xiangdong Xu, A. M. Pourrahimi, Christian Müller, Y. Serdyuk
{"title":"短路诱导XLPE中的直流电气树","authors":"S. Kumara, T. Hammarström, Xiangdong Xu, A. M. Pourrahimi, Christian Müller, Y. Serdyuk","doi":"10.1109/CEIDP50766.2021.9705362","DOIUrl":null,"url":null,"abstract":"This study aims at understanding electrical treeing in XLPE due to DC short circuits. A wire-plane type test object has been excited by a series of short circuit events after applying DC voltages of different levels and duration. The development of thin filamentary trees and their morphology was correlated with the inception probability. It was observed that the latter as well as the length of the trees increased with the magnitude of the applied voltage and the number of short circuit events. These observations are in good agreement with the hypothesis that the release of stored energy during short circuit causes electromechanical stresses in the materials giving rise to treeing process analogous to mechanical crack formation. It is suggested that the application of an adequate number of short circuits at a suitable voltage level and a sufficient stress duration can be used as a DC treeing test procedure.","PeriodicalId":6837,"journal":{"name":"2021 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","volume":"38 1","pages":"275-278"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"DC Electrical Trees in XLPE Induced by Short Circuits\",\"authors\":\"S. Kumara, T. Hammarström, Xiangdong Xu, A. M. Pourrahimi, Christian Müller, Y. Serdyuk\",\"doi\":\"10.1109/CEIDP50766.2021.9705362\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study aims at understanding electrical treeing in XLPE due to DC short circuits. A wire-plane type test object has been excited by a series of short circuit events after applying DC voltages of different levels and duration. The development of thin filamentary trees and their morphology was correlated with the inception probability. It was observed that the latter as well as the length of the trees increased with the magnitude of the applied voltage and the number of short circuit events. These observations are in good agreement with the hypothesis that the release of stored energy during short circuit causes electromechanical stresses in the materials giving rise to treeing process analogous to mechanical crack formation. It is suggested that the application of an adequate number of short circuits at a suitable voltage level and a sufficient stress duration can be used as a DC treeing test procedure.\",\"PeriodicalId\":6837,\"journal\":{\"name\":\"2021 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)\",\"volume\":\"38 1\",\"pages\":\"275-278\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP50766.2021.9705362\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP50766.2021.9705362","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本研究旨在了解XLPE因直流短路而产生的电气树。在施加不同等级和持续时间的直流电压后,线平面型试验对象受到一系列短路事件的激励。细丝状乔木的发育及其形态与初始概率相关。观察到,后者以及树的长度随着施加电压的大小和短路事件的数量而增加。这些观察结果很好地与假设一致,即在短路期间释放存储的能量会导致材料中的机电应力,从而产生类似于机械裂纹形成的树状过程。建议在适当的电压水平和足够的应力持续时间下应用足够数量的短路可以作为直流树试验程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
DC Electrical Trees in XLPE Induced by Short Circuits
This study aims at understanding electrical treeing in XLPE due to DC short circuits. A wire-plane type test object has been excited by a series of short circuit events after applying DC voltages of different levels and duration. The development of thin filamentary trees and their morphology was correlated with the inception probability. It was observed that the latter as well as the length of the trees increased with the magnitude of the applied voltage and the number of short circuit events. These observations are in good agreement with the hypothesis that the release of stored energy during short circuit causes electromechanical stresses in the materials giving rise to treeing process analogous to mechanical crack formation. It is suggested that the application of an adequate number of short circuits at a suitable voltage level and a sufficient stress duration can be used as a DC treeing test procedure.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信