串联质谱法测定盐酸昂丹司琼中潜在遗传毒性杂质苯基肼的含量

Palnati Narmada Kotapati Nalini, G. Vaidyanathan
{"title":"串联质谱法测定盐酸昂丹司琼中潜在遗传毒性杂质苯基肼的含量","authors":"Palnati Narmada Kotapati Nalini, G. Vaidyanathan","doi":"10.46624/ajptr.2020.v10.i5.003","DOIUrl":null,"url":null,"abstract":"To estimate the level of Phenylhydrazine, a potential genotoxic impurity in Ondansetron Hydrochloride API, a new simple, sensitive and accurate method was developed using Liquid Chromatographic Mass Spectrometry (LC-MS/MS). The chromatographic separation was achieved on Inert Sustain Swift C18, 5μ (150 x 4.6) mm column with gradient programme and elution was monitored by mass spectrometer in Multiple Reaction Monitoring mode using electrospray ionization. The LOD and LOQ values found to be 5 ppm and 15 ppm for the impurity with respect to the test concentration 2 mg/ml. The method was linear (r>0.99), precise (RSD<2%), accurate and well within acceptable ICH limits.","PeriodicalId":7701,"journal":{"name":"American Journal of PharmTech Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantitative Method For The Determination Of Phenyl Hydrazine, A Potential Genotoxic Impurity Of Ondansetron Hydrochloride Using Tandem Mass Spectrometry\",\"authors\":\"Palnati Narmada Kotapati Nalini, G. Vaidyanathan\",\"doi\":\"10.46624/ajptr.2020.v10.i5.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To estimate the level of Phenylhydrazine, a potential genotoxic impurity in Ondansetron Hydrochloride API, a new simple, sensitive and accurate method was developed using Liquid Chromatographic Mass Spectrometry (LC-MS/MS). The chromatographic separation was achieved on Inert Sustain Swift C18, 5μ (150 x 4.6) mm column with gradient programme and elution was monitored by mass spectrometer in Multiple Reaction Monitoring mode using electrospray ionization. The LOD and LOQ values found to be 5 ppm and 15 ppm for the impurity with respect to the test concentration 2 mg/ml. The method was linear (r>0.99), precise (RSD<2%), accurate and well within acceptable ICH limits.\",\"PeriodicalId\":7701,\"journal\":{\"name\":\"American Journal of PharmTech Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of PharmTech Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.46624/ajptr.2020.v10.i5.003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of PharmTech Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46624/ajptr.2020.v10.i5.003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为测定盐酸昂丹司琼原料药中潜在遗传毒性杂质苯肼的含量,建立了一种简便、灵敏、准确的液相色谱-质谱(LC-MS/MS)方法。色谱柱为Inert Sustain Swift C18,色谱柱为5μ (150 x 4.6) mm,采用梯度程序,质谱联用,电喷雾电离,多重反应监测模式。相对于测试浓度2mg /ml,杂质的LOD和LOQ值分别为5ppm和15ppm。该方法线性(r>0.99),精密度(RSD<2%),准确度在可接受的ICH范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Quantitative Method For The Determination Of Phenyl Hydrazine, A Potential Genotoxic Impurity Of Ondansetron Hydrochloride Using Tandem Mass Spectrometry
To estimate the level of Phenylhydrazine, a potential genotoxic impurity in Ondansetron Hydrochloride API, a new simple, sensitive and accurate method was developed using Liquid Chromatographic Mass Spectrometry (LC-MS/MS). The chromatographic separation was achieved on Inert Sustain Swift C18, 5μ (150 x 4.6) mm column with gradient programme and elution was monitored by mass spectrometer in Multiple Reaction Monitoring mode using electrospray ionization. The LOD and LOQ values found to be 5 ppm and 15 ppm for the impurity with respect to the test concentration 2 mg/ml. The method was linear (r>0.99), precise (RSD<2%), accurate and well within acceptable ICH limits.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信