{"title":"混凝土T梁桥加固用外粘结复合材料","authors":"S. Morton","doi":"10.14359/5664","DOIUrl":null,"url":null,"abstract":"This paper presents the results of laboratory testing of concrete beams and field testing of two concrete T-beam bridges that were externally strengthened with CFRP. As a result of the lab testing all the systems tested showed a considerable increase of 68% for the ultimate strength and 45% decrease in deflection for the beams with 2-#4 reinforcing bars. The beams with 2-#7 reinforcing bars showed a 60% increase in ultimate strength and a 26% decrease in deflection when comparing the loads that produced yielding of the steel in the baseline and the 5 layer test. Both structures were load tested and monitored before and after application of the CFRP with strain gages and LVDTs. The results showed an increase up to 8% in stiffness and up to 15% decrease in strain. In addition to the load test a quality assurance NDT evaluation was performed on the bond using infrared thermography. The results showed typically less than 2% voids between the CFRP and the concrete.","PeriodicalId":68258,"journal":{"name":"玻璃钢","volume":"8 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"1999-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Externally Bonded Composites for Strengthening Concrete T- Beam Bridges\",\"authors\":\"S. Morton\",\"doi\":\"10.14359/5664\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the results of laboratory testing of concrete beams and field testing of two concrete T-beam bridges that were externally strengthened with CFRP. As a result of the lab testing all the systems tested showed a considerable increase of 68% for the ultimate strength and 45% decrease in deflection for the beams with 2-#4 reinforcing bars. The beams with 2-#7 reinforcing bars showed a 60% increase in ultimate strength and a 26% decrease in deflection when comparing the loads that produced yielding of the steel in the baseline and the 5 layer test. Both structures were load tested and monitored before and after application of the CFRP with strain gages and LVDTs. The results showed an increase up to 8% in stiffness and up to 15% decrease in strain. In addition to the load test a quality assurance NDT evaluation was performed on the bond using infrared thermography. The results showed typically less than 2% voids between the CFRP and the concrete.\",\"PeriodicalId\":68258,\"journal\":{\"name\":\"玻璃钢\",\"volume\":\"8 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"玻璃钢\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.14359/5664\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"玻璃钢","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.14359/5664","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Externally Bonded Composites for Strengthening Concrete T- Beam Bridges
This paper presents the results of laboratory testing of concrete beams and field testing of two concrete T-beam bridges that were externally strengthened with CFRP. As a result of the lab testing all the systems tested showed a considerable increase of 68% for the ultimate strength and 45% decrease in deflection for the beams with 2-#4 reinforcing bars. The beams with 2-#7 reinforcing bars showed a 60% increase in ultimate strength and a 26% decrease in deflection when comparing the loads that produced yielding of the steel in the baseline and the 5 layer test. Both structures were load tested and monitored before and after application of the CFRP with strain gages and LVDTs. The results showed an increase up to 8% in stiffness and up to 15% decrease in strain. In addition to the load test a quality assurance NDT evaluation was performed on the bond using infrared thermography. The results showed typically less than 2% voids between the CFRP and the concrete.