基于检测数据和载荷测量的FPSO船体和甲板结构监测数字孪生

S. Bhat, Varadarajan Nadathur, D. Knezevic, P. Aalberts, H. Kolsters, Daniel Amuda, Orobome Atebe, D. Pasala, Tuyen Hoang, T. Luong, Phuong Huynh, Riccardo Righetti, R. Hageman, Jim Yu
{"title":"基于检测数据和载荷测量的FPSO船体和甲板结构监测数字孪生","authors":"S. Bhat, Varadarajan Nadathur, D. Knezevic, P. Aalberts, H. Kolsters, Daniel Amuda, Orobome Atebe, D. Pasala, Tuyen Hoang, T. Luong, Phuong Huynh, Riccardo Righetti, R. Hageman, Jim Yu","doi":"10.4043/31328-ms","DOIUrl":null,"url":null,"abstract":"\n A high-fidelity FPSO Structural Digital Twin (SDT) based on Reduced Basis Finite Element Analysis (RB-FEA) coupled with inspection data and physical sensor measurements (advisory hull monitoring system) is presented to demonstrate a complete FPSO \"digital thread\" that combines operational data feeds, detailed structural analysis based on as-is asset condition, and automated structural integrity reporting. This lays the groundwork for a philosophical shift for asset lifecycle management by enabling the use of \"as-measured\" conditions in lieu of assumed \"design-conditions\" for a more accurate, and robust understanding of asset health. We demonstrate the deployment of this methodology for the Bonga FPSO and discuss the value that it brings during day-to-day operations.","PeriodicalId":11072,"journal":{"name":"Day 1 Mon, August 16, 2021","volume":"71 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Structural Digital Twin of FPSO for Monitoring the Hull and Topsides Based on Inspection Data and Load Measurement\",\"authors\":\"S. Bhat, Varadarajan Nadathur, D. Knezevic, P. Aalberts, H. Kolsters, Daniel Amuda, Orobome Atebe, D. Pasala, Tuyen Hoang, T. Luong, Phuong Huynh, Riccardo Righetti, R. Hageman, Jim Yu\",\"doi\":\"10.4043/31328-ms\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n A high-fidelity FPSO Structural Digital Twin (SDT) based on Reduced Basis Finite Element Analysis (RB-FEA) coupled with inspection data and physical sensor measurements (advisory hull monitoring system) is presented to demonstrate a complete FPSO \\\"digital thread\\\" that combines operational data feeds, detailed structural analysis based on as-is asset condition, and automated structural integrity reporting. This lays the groundwork for a philosophical shift for asset lifecycle management by enabling the use of \\\"as-measured\\\" conditions in lieu of assumed \\\"design-conditions\\\" for a more accurate, and robust understanding of asset health. We demonstrate the deployment of this methodology for the Bonga FPSO and discuss the value that it brings during day-to-day operations.\",\"PeriodicalId\":11072,\"journal\":{\"name\":\"Day 1 Mon, August 16, 2021\",\"volume\":\"71 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Day 1 Mon, August 16, 2021\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4043/31328-ms\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 1 Mon, August 16, 2021","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4043/31328-ms","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

基于降基有限元分析(RB-FEA),结合检查数据和物理传感器测量(咨询船体监测系统)的高保真FPSO结构数字孪生(SDT),展示了一个完整的FPSO“数字线索”,它结合了操作数据馈送、基于现有资产状况的详细结构分析和自动结构完整性报告。这为资产生命周期管理的哲学转变奠定了基础,通过使用“测量”条件来代替假设的“设计条件”,从而更准确、更可靠地了解资产健康状况。我们在Bonga FPSO上演示了这种方法的应用,并讨论了它在日常运营中带来的价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Structural Digital Twin of FPSO for Monitoring the Hull and Topsides Based on Inspection Data and Load Measurement
A high-fidelity FPSO Structural Digital Twin (SDT) based on Reduced Basis Finite Element Analysis (RB-FEA) coupled with inspection data and physical sensor measurements (advisory hull monitoring system) is presented to demonstrate a complete FPSO "digital thread" that combines operational data feeds, detailed structural analysis based on as-is asset condition, and automated structural integrity reporting. This lays the groundwork for a philosophical shift for asset lifecycle management by enabling the use of "as-measured" conditions in lieu of assumed "design-conditions" for a more accurate, and robust understanding of asset health. We demonstrate the deployment of this methodology for the Bonga FPSO and discuss the value that it brings during day-to-day operations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信