Sicheng Wu, Jian Li, Linjie Zhao, Yan Wang, Zhiman He, Lianwei Bao
{"title":"电热老化过程中油纸绝缘的空间电荷特性","authors":"Sicheng Wu, Jian Li, Linjie Zhao, Yan Wang, Zhiman He, Lianwei Bao","doi":"10.1109/ICHVE.2012.6357125","DOIUrl":null,"url":null,"abstract":"Valve windings of converter transformer withstand pulsating voltages. In order to reveal the relationship between the properties of space charge and electrical-thermal aging of oil-paper insulation in converter transformer, this paper did the electrical-thermal aging test at 70 °C under 7.6kV pulsating DC voltage and obtained the samples of different aging time. The internal space charge injection and accumulation properties of aged samples under 20kV/mm and 30kV/mm DC electric field was measured and analyzed by the Pulsed Electro-Acoustic (PEA) method. The results showed that homo-charges injection still occurs at both electrodes in the electrical-thermal aging samples. Aged oil-paper insulation was dominated by negative charge injection as the stressing time increases, which directly cause hetero-charge accumulation in the vicinity of the anode, and homo-charge accumulation near the cathode. It could help explain the reason of the electrical-thermal aging lifetime of oil-paper in sulation is obviously shorter than the electrical or thermal aging. In addition, the longer the aging time, the more the total charge accumulated in the samples.","PeriodicalId":6375,"journal":{"name":"2012 International Conference on High Voltage Engineering and Application","volume":"1 1","pages":"269-273"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"The properties of space charge in oil-paper insulation during electrical-thermal aging\",\"authors\":\"Sicheng Wu, Jian Li, Linjie Zhao, Yan Wang, Zhiman He, Lianwei Bao\",\"doi\":\"10.1109/ICHVE.2012.6357125\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Valve windings of converter transformer withstand pulsating voltages. In order to reveal the relationship between the properties of space charge and electrical-thermal aging of oil-paper insulation in converter transformer, this paper did the electrical-thermal aging test at 70 °C under 7.6kV pulsating DC voltage and obtained the samples of different aging time. The internal space charge injection and accumulation properties of aged samples under 20kV/mm and 30kV/mm DC electric field was measured and analyzed by the Pulsed Electro-Acoustic (PEA) method. The results showed that homo-charges injection still occurs at both electrodes in the electrical-thermal aging samples. Aged oil-paper insulation was dominated by negative charge injection as the stressing time increases, which directly cause hetero-charge accumulation in the vicinity of the anode, and homo-charge accumulation near the cathode. It could help explain the reason of the electrical-thermal aging lifetime of oil-paper in sulation is obviously shorter than the electrical or thermal aging. In addition, the longer the aging time, the more the total charge accumulated in the samples.\",\"PeriodicalId\":6375,\"journal\":{\"name\":\"2012 International Conference on High Voltage Engineering and Application\",\"volume\":\"1 1\",\"pages\":\"269-273\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on High Voltage Engineering and Application\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE.2012.6357125\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on High Voltage Engineering and Application","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE.2012.6357125","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The properties of space charge in oil-paper insulation during electrical-thermal aging
Valve windings of converter transformer withstand pulsating voltages. In order to reveal the relationship between the properties of space charge and electrical-thermal aging of oil-paper insulation in converter transformer, this paper did the electrical-thermal aging test at 70 °C under 7.6kV pulsating DC voltage and obtained the samples of different aging time. The internal space charge injection and accumulation properties of aged samples under 20kV/mm and 30kV/mm DC electric field was measured and analyzed by the Pulsed Electro-Acoustic (PEA) method. The results showed that homo-charges injection still occurs at both electrodes in the electrical-thermal aging samples. Aged oil-paper insulation was dominated by negative charge injection as the stressing time increases, which directly cause hetero-charge accumulation in the vicinity of the anode, and homo-charge accumulation near the cathode. It could help explain the reason of the electrical-thermal aging lifetime of oil-paper in sulation is obviously shorter than the electrical or thermal aging. In addition, the longer the aging time, the more the total charge accumulated in the samples.