用于室内空气监测的WiFi电子鼻

C. Wongchoosuk, C. Khunarak, M. Lutz, T. Kerdcharoen
{"title":"用于室内空气监测的WiFi电子鼻","authors":"C. Wongchoosuk, C. Khunarak, M. Lutz, T. Kerdcharoen","doi":"10.1109/ECTICON.2012.6254166","DOIUrl":null,"url":null,"abstract":"Several indoor chemical contaminants such as CO and NO2 are highly toxic. Inhalation of CO or NO2 as low as ppm level may cause respiratory distress or failure. Therefore, detection of indoor air is very important in the industrial, medical, and environmental applications. In this paper, a new electronic nose (E-nose) architecture has been proposed for the real-time quantification and qualification of indoor air contaminations. The metal oxide TGS gas sensors were used as the sensing part. The principal component analysis (PCA) method and a set of mathematical model were employed in data analysis. By combining with the proposed mathematical model, this E-nose can estimate the amount of CO gas contaminations in air at ppm levels. Moreover, the PCA results can clearly show a classification between two different rooms.","PeriodicalId":6319,"journal":{"name":"2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology","volume":"80 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"WiFi electronic nose for indoor air monitoring\",\"authors\":\"C. Wongchoosuk, C. Khunarak, M. Lutz, T. Kerdcharoen\",\"doi\":\"10.1109/ECTICON.2012.6254166\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Several indoor chemical contaminants such as CO and NO2 are highly toxic. Inhalation of CO or NO2 as low as ppm level may cause respiratory distress or failure. Therefore, detection of indoor air is very important in the industrial, medical, and environmental applications. In this paper, a new electronic nose (E-nose) architecture has been proposed for the real-time quantification and qualification of indoor air contaminations. The metal oxide TGS gas sensors were used as the sensing part. The principal component analysis (PCA) method and a set of mathematical model were employed in data analysis. By combining with the proposed mathematical model, this E-nose can estimate the amount of CO gas contaminations in air at ppm levels. Moreover, the PCA results can clearly show a classification between two different rooms.\",\"PeriodicalId\":6319,\"journal\":{\"name\":\"2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology\",\"volume\":\"80 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECTICON.2012.6254166\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTICON.2012.6254166","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

一些室内化学污染物如CO和NO2是剧毒的。吸入低至ppm水平的CO或NO2可能导致呼吸窘迫或呼吸衰竭。因此,室内空气的检测在工业、医疗和环境应用中非常重要。本文提出了一种新的电子鼻结构,用于室内空气污染的实时量化和定性。传感部分采用金属氧化物TGS气体传感器。数据分析采用主成分分析(PCA)方法和一套数学模型。通过与所提出的数学模型相结合,这个电子鼻可以以ppm的水平估计空气中CO气体污染物的数量。此外,PCA结果可以清楚地显示两个不同房间之间的分类。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
WiFi electronic nose for indoor air monitoring
Several indoor chemical contaminants such as CO and NO2 are highly toxic. Inhalation of CO or NO2 as low as ppm level may cause respiratory distress or failure. Therefore, detection of indoor air is very important in the industrial, medical, and environmental applications. In this paper, a new electronic nose (E-nose) architecture has been proposed for the real-time quantification and qualification of indoor air contaminations. The metal oxide TGS gas sensors were used as the sensing part. The principal component analysis (PCA) method and a set of mathematical model were employed in data analysis. By combining with the proposed mathematical model, this E-nose can estimate the amount of CO gas contaminations in air at ppm levels. Moreover, the PCA results can clearly show a classification between two different rooms.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信