{"title":"高频几何聚焦三角柱复合换能器的制造与性能研究","authors":"J. A. Brown, E. Chérin, Jianhua Yin, F. S. Foster","doi":"10.1109/ULTSYM.2007.33","DOIUrl":null,"url":null,"abstract":"A single-element, 40 MHz, 3 mm diameter transducer was fabricated with a geometric focus at 9 mm. The transducer was based on a piezo-composite substrate with triangular-shaped composite pillars. The transducer produced pulses with a two-way bandwidth of 55 %. The bandwidth and impedance magnitude were in agreement with that predicted using finite element modeling. A one-way radiation pattern was collected using a needle hydrophone. The oneway -3 dB beamwidth at the geometric focus was measured to be 120 mum and the -3 dB depth-of-field was 2.5 mm This is in good agreement to the theoretical predictions of 112.5 mum and 2.4 mm The triangular-pillar composite transducer was then compared to a transducer with square composite pillars. A 12 dB reduction in the amplitude of the secondary resonance was found for the triangular- pillar composite.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"39 1","pages":"80-83"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"2F-1 Fabrication and Performance of a High-Frequency Geometrically Focussed Composite Transducer with Triangular Pillar Geometry\",\"authors\":\"J. A. Brown, E. Chérin, Jianhua Yin, F. S. Foster\",\"doi\":\"10.1109/ULTSYM.2007.33\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A single-element, 40 MHz, 3 mm diameter transducer was fabricated with a geometric focus at 9 mm. The transducer was based on a piezo-composite substrate with triangular-shaped composite pillars. The transducer produced pulses with a two-way bandwidth of 55 %. The bandwidth and impedance magnitude were in agreement with that predicted using finite element modeling. A one-way radiation pattern was collected using a needle hydrophone. The oneway -3 dB beamwidth at the geometric focus was measured to be 120 mum and the -3 dB depth-of-field was 2.5 mm This is in good agreement to the theoretical predictions of 112.5 mum and 2.4 mm The triangular-pillar composite transducer was then compared to a transducer with square composite pillars. A 12 dB reduction in the amplitude of the secondary resonance was found for the triangular- pillar composite.\",\"PeriodicalId\":6355,\"journal\":{\"name\":\"2007 IEEE Ultrasonics Symposium Proceedings\",\"volume\":\"39 1\",\"pages\":\"80-83\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Ultrasonics Symposium Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2007.33\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Ultrasonics Symposium Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2007.33","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
2F-1 Fabrication and Performance of a High-Frequency Geometrically Focussed Composite Transducer with Triangular Pillar Geometry
A single-element, 40 MHz, 3 mm diameter transducer was fabricated with a geometric focus at 9 mm. The transducer was based on a piezo-composite substrate with triangular-shaped composite pillars. The transducer produced pulses with a two-way bandwidth of 55 %. The bandwidth and impedance magnitude were in agreement with that predicted using finite element modeling. A one-way radiation pattern was collected using a needle hydrophone. The oneway -3 dB beamwidth at the geometric focus was measured to be 120 mum and the -3 dB depth-of-field was 2.5 mm This is in good agreement to the theoretical predictions of 112.5 mum and 2.4 mm The triangular-pillar composite transducer was then compared to a transducer with square composite pillars. A 12 dB reduction in the amplitude of the secondary resonance was found for the triangular- pillar composite.