案例研究:润滑油冷却器风扇联轴器连续失效

A. Manikandan, Zeeshan Anwar
{"title":"案例研究:润滑油冷却器风扇联轴器连续失效","authors":"A. Manikandan, Zeeshan Anwar","doi":"10.2118/206120-ms","DOIUrl":null,"url":null,"abstract":"\n Do we analyze on why can even the most reliable turbomachinery are getting failure and stopped? In some cases, it's all about bad installation or design literally. This paper explores the challenges one site had with repeated failure of lube oil fin fan coolers coupling which caused the unit availability of more than 3 months. It outlines the troubleshooting attempts made to remedy this issue, its root cause, and the resulting solution.\n This issue occurred at a site with a train configuration of motor driven centrifugal compressors. The plant lube oil system has been configured with 3 trains. Each train has been configured with Main electric motor + Vorecon Gearbox + Low Pressure centrifugal compressor + High Pressure centrifugal compressor. Lube oil system of the train has been configured as 2 lube oil coolers and 2 working oil coolers. Lube oil coolers are having fins with air cooler type. Air is supplied by fin fans and each train has 2 lube oil cooler fans and 2 working oil cooler fans. In total site has 3 trains x 4 fin fans so it has 12 fin fan cooler fans. All cooler fans are driven by electric motor which is coupled with gearbox and gear box is connected with cooler fan.\n During normal operation of working oil cooler fan A- stopped rotation suddenly from normal operation. During investigation, motor shaft was found running freely. No movement was seen on cooler fan. Coupling between motor to gearbox was inspected. Coupling is shear plate coupling. Its spacer flexible element were found broken into several pieces. Further investigation revealed that motor coupling hub was moving free axially back and forth due to clearance between motor shaft to coupling hub internal diameter. Motor side Coupling hub bolt hole was found with loss of material and ovality in shape. Hub locking Allen screw was found in damaged condition. Missing materials were noted and broken shear plate materials were found around coupling guard area.\n While site team was conducting the investigation on the unit A, similar incident occurred in next unit and other 3 units with 2 days difference between them.\n During detailed investigation it has been noted that all motor to gear box coupling are shear plates and shear plates were broken. Coupling hub was found loose and coupling hub locking screw was found broken or partial damage.","PeriodicalId":10896,"journal":{"name":"Day 1 Tue, September 21, 2021","volume":"39 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Case Study: Consecutive Failure of Lube Oil Cooler Fans Coupling\",\"authors\":\"A. Manikandan, Zeeshan Anwar\",\"doi\":\"10.2118/206120-ms\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Do we analyze on why can even the most reliable turbomachinery are getting failure and stopped? In some cases, it's all about bad installation or design literally. This paper explores the challenges one site had with repeated failure of lube oil fin fan coolers coupling which caused the unit availability of more than 3 months. It outlines the troubleshooting attempts made to remedy this issue, its root cause, and the resulting solution.\\n This issue occurred at a site with a train configuration of motor driven centrifugal compressors. The plant lube oil system has been configured with 3 trains. Each train has been configured with Main electric motor + Vorecon Gearbox + Low Pressure centrifugal compressor + High Pressure centrifugal compressor. Lube oil system of the train has been configured as 2 lube oil coolers and 2 working oil coolers. Lube oil coolers are having fins with air cooler type. Air is supplied by fin fans and each train has 2 lube oil cooler fans and 2 working oil cooler fans. In total site has 3 trains x 4 fin fans so it has 12 fin fan cooler fans. All cooler fans are driven by electric motor which is coupled with gearbox and gear box is connected with cooler fan.\\n During normal operation of working oil cooler fan A- stopped rotation suddenly from normal operation. During investigation, motor shaft was found running freely. No movement was seen on cooler fan. Coupling between motor to gearbox was inspected. Coupling is shear plate coupling. Its spacer flexible element were found broken into several pieces. Further investigation revealed that motor coupling hub was moving free axially back and forth due to clearance between motor shaft to coupling hub internal diameter. Motor side Coupling hub bolt hole was found with loss of material and ovality in shape. Hub locking Allen screw was found in damaged condition. Missing materials were noted and broken shear plate materials were found around coupling guard area.\\n While site team was conducting the investigation on the unit A, similar incident occurred in next unit and other 3 units with 2 days difference between them.\\n During detailed investigation it has been noted that all motor to gear box coupling are shear plates and shear plates were broken. Coupling hub was found loose and coupling hub locking screw was found broken or partial damage.\",\"PeriodicalId\":10896,\"journal\":{\"name\":\"Day 1 Tue, September 21, 2021\",\"volume\":\"39 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Day 1 Tue, September 21, 2021\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2118/206120-ms\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 1 Tue, September 21, 2021","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2118/206120-ms","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们是否分析过为什么即使是最可靠的涡轮机械也会出现故障和停机?在某些情况下,这完全是因为糟糕的安装或设计。本文探讨了某厂址润滑油翅片风机冷却器联轴器多次失效导致机组可用性超过3个月的问题。它概述了为解决此问题而进行的故障排除尝试、其根本原因以及由此产生的解决方案。该问题发生在电机驱动离心压缩机的列车配置现场。工厂润滑油系统配置了3列。每列配置主电机+ Vorecon变速箱+低压离心压缩机+高压离心压缩机。列车润滑油系统配置为2台润滑油冷却器和2台工作油冷却器。润滑油冷却器有空气冷却器类型的翅片。空气由翅片风扇供应,每列火车有2个润滑油冷却风扇和2个工作油冷却风扇。总的站点有3个列车x 4个翅片风扇,所以它有12个翅片风扇冷却风扇。所有冷却器风扇由电动机驱动,电动机与齿轮箱耦合,齿轮箱与冷却器风扇连接。正常工作时,油冷却器风扇A突然停止转动,脱离正常工作。在调查过程中,发现电机轴运转自如。冷却风扇未见任何移动。检查了电机与齿轮箱之间的耦合。联轴器为剪力板联轴器。它的间隔柔性元件被发现碎成几块。进一步的研究表明,由于电机轴与联轴器内径之间的间隙,电机联轴器轮毂在轴向上自由来回移动。电机侧联轴器轮毂螺栓孔出现材料损耗,形状呈椭圆形。轮毂锁紧内六角螺钉被发现损坏。注意到材料缺失,在耦合防护区域发现剪切板断裂。现场小组在对A单元进行调查时,下一个单元和其他3个单元也发生了类似事件,时间相差2天。在详细的调查中发现,所有的电机与齿轮箱联轴器都是剪切板,剪切板被破坏了。发现联轴器轮毂松动,联轴器锁紧螺钉断裂或部分损坏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Case Study: Consecutive Failure of Lube Oil Cooler Fans Coupling
Do we analyze on why can even the most reliable turbomachinery are getting failure and stopped? In some cases, it's all about bad installation or design literally. This paper explores the challenges one site had with repeated failure of lube oil fin fan coolers coupling which caused the unit availability of more than 3 months. It outlines the troubleshooting attempts made to remedy this issue, its root cause, and the resulting solution. This issue occurred at a site with a train configuration of motor driven centrifugal compressors. The plant lube oil system has been configured with 3 trains. Each train has been configured with Main electric motor + Vorecon Gearbox + Low Pressure centrifugal compressor + High Pressure centrifugal compressor. Lube oil system of the train has been configured as 2 lube oil coolers and 2 working oil coolers. Lube oil coolers are having fins with air cooler type. Air is supplied by fin fans and each train has 2 lube oil cooler fans and 2 working oil cooler fans. In total site has 3 trains x 4 fin fans so it has 12 fin fan cooler fans. All cooler fans are driven by electric motor which is coupled with gearbox and gear box is connected with cooler fan. During normal operation of working oil cooler fan A- stopped rotation suddenly from normal operation. During investigation, motor shaft was found running freely. No movement was seen on cooler fan. Coupling between motor to gearbox was inspected. Coupling is shear plate coupling. Its spacer flexible element were found broken into several pieces. Further investigation revealed that motor coupling hub was moving free axially back and forth due to clearance between motor shaft to coupling hub internal diameter. Motor side Coupling hub bolt hole was found with loss of material and ovality in shape. Hub locking Allen screw was found in damaged condition. Missing materials were noted and broken shear plate materials were found around coupling guard area. While site team was conducting the investigation on the unit A, similar incident occurred in next unit and other 3 units with 2 days difference between them. During detailed investigation it has been noted that all motor to gear box coupling are shear plates and shear plates were broken. Coupling hub was found loose and coupling hub locking screw was found broken or partial damage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信