利用印度加尔各答特定场地地面运动的建筑物性能

IF 0.5 Q4 ENGINEERING, GEOLOGICAL
A. Shiuly
{"title":"利用印度加尔各答特定场地地面运动的建筑物性能","authors":"A. Shiuly","doi":"10.4018/IJGEE.2019010102","DOIUrl":null,"url":null,"abstract":"Kolkata, capital of West Bengal, India, is presently congested with moderate to high rise buildings, and may undergo damage during future earthquakes due to the amplification of seismic waves by the soft alluvial soil. Further, most of the buildings are open ground storey (OGS), which is very vulnerable to earthquakes. Therefore, in the present study, the performance of some typical G+1, G+4 and G+9 storied buildings are analyzed using the available site-specific time history of the city by non-linear time history analysis (NLTHA). The analysis has been carried out for maximum considerable earthquake (MCE) and design basis earthquake (DBE) by both considering the stiffness of the infill wall (WI) and without considering stiffness of infill wall (WOI). The result signifies that, in almost all locations, the percentage of roof displacements obtained by site specific time history are more than the Indian codal compatible time history for both WI and WOI. Thus, performance will not be satisfactory for the buildings which are designed according to the Indian seismic code. The present study also corroborates that for almost all the buildings, the ground storey drift remains below immediate occupancy (IO) level during DBE and it varies IO to life safety (LS) level during MCE. However, all the storey drift are below Collapse Prevention (CP) limit. It is to be mentioned that for all the buildings the inter storey drift is higher than the Indian codal (IS-1893 (Part 1):2016) permissible limit (0.4%) during both DBE and MCE. However, the storey drifts result for WI buildings are comparatively lower than WOI buildings which are due to addition of stiffness of infill in each floor and fundamental modal spectral acceleration is lower.","PeriodicalId":42473,"journal":{"name":"International Journal of Geotechnical Earthquake Engineering","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Performance of Buildings Using Site Specific Ground Motion of Kolkata, India\",\"authors\":\"A. Shiuly\",\"doi\":\"10.4018/IJGEE.2019010102\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Kolkata, capital of West Bengal, India, is presently congested with moderate to high rise buildings, and may undergo damage during future earthquakes due to the amplification of seismic waves by the soft alluvial soil. Further, most of the buildings are open ground storey (OGS), which is very vulnerable to earthquakes. Therefore, in the present study, the performance of some typical G+1, G+4 and G+9 storied buildings are analyzed using the available site-specific time history of the city by non-linear time history analysis (NLTHA). The analysis has been carried out for maximum considerable earthquake (MCE) and design basis earthquake (DBE) by both considering the stiffness of the infill wall (WI) and without considering stiffness of infill wall (WOI). The result signifies that, in almost all locations, the percentage of roof displacements obtained by site specific time history are more than the Indian codal compatible time history for both WI and WOI. Thus, performance will not be satisfactory for the buildings which are designed according to the Indian seismic code. The present study also corroborates that for almost all the buildings, the ground storey drift remains below immediate occupancy (IO) level during DBE and it varies IO to life safety (LS) level during MCE. However, all the storey drift are below Collapse Prevention (CP) limit. It is to be mentioned that for all the buildings the inter storey drift is higher than the Indian codal (IS-1893 (Part 1):2016) permissible limit (0.4%) during both DBE and MCE. However, the storey drifts result for WI buildings are comparatively lower than WOI buildings which are due to addition of stiffness of infill in each floor and fundamental modal spectral acceleration is lower.\",\"PeriodicalId\":42473,\"journal\":{\"name\":\"International Journal of Geotechnical Earthquake Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Geotechnical Earthquake Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4018/IJGEE.2019010102\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, GEOLOGICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Geotechnical Earthquake Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4018/IJGEE.2019010102","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, GEOLOGICAL","Score":null,"Total":0}
引用次数: 1

摘要

加尔各答是印度西孟加拉邦的首府,目前到处都是中高层建筑,由于软冲积土对地震波的放大,在未来的地震中可能会受到破坏。此外,大多数建筑物都是开放的地面层(OGS),非常容易受到地震的影响。因此,本研究采用非线性时程分析(NLTHA)方法,利用城市现有的场地特定时程,对典型的G+1、G+4和G+9层建筑的性能进行分析。分别考虑填充墙刚度(WI)和不考虑填充墙刚度(WOI),对最大可观地震(MCE)和设计基础地震(DBE)进行了分析。结果表明,在几乎所有的位置,场地特定时间历史获得的屋顶位移百分比都大于WI和WOI的印度代码兼容时间历史。因此,按照印度抗震规范设计的建筑物的性能将不能令人满意。本研究还证实,对于几乎所有建筑物,在DBE期间,地面层漂移保持在直接占用(IO)水平以下,在MCE期间,它改变了IO到生命安全(LS)水平。然而,所有层间漂移均在防塌限值以下。值得一提的是,在DBE和MCE期间,所有建筑物的层间漂移都高于印度规范(is -1893 (Part 1):2016)的允许极限(0.4%)。然而,WI建筑的楼层漂移结果相对较低,这是由于每层填充刚度的增加,基本模态谱加速度更低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance of Buildings Using Site Specific Ground Motion of Kolkata, India
Kolkata, capital of West Bengal, India, is presently congested with moderate to high rise buildings, and may undergo damage during future earthquakes due to the amplification of seismic waves by the soft alluvial soil. Further, most of the buildings are open ground storey (OGS), which is very vulnerable to earthquakes. Therefore, in the present study, the performance of some typical G+1, G+4 and G+9 storied buildings are analyzed using the available site-specific time history of the city by non-linear time history analysis (NLTHA). The analysis has been carried out for maximum considerable earthquake (MCE) and design basis earthquake (DBE) by both considering the stiffness of the infill wall (WI) and without considering stiffness of infill wall (WOI). The result signifies that, in almost all locations, the percentage of roof displacements obtained by site specific time history are more than the Indian codal compatible time history for both WI and WOI. Thus, performance will not be satisfactory for the buildings which are designed according to the Indian seismic code. The present study also corroborates that for almost all the buildings, the ground storey drift remains below immediate occupancy (IO) level during DBE and it varies IO to life safety (LS) level during MCE. However, all the storey drift are below Collapse Prevention (CP) limit. It is to be mentioned that for all the buildings the inter storey drift is higher than the Indian codal (IS-1893 (Part 1):2016) permissible limit (0.4%) during both DBE and MCE. However, the storey drifts result for WI buildings are comparatively lower than WOI buildings which are due to addition of stiffness of infill in each floor and fundamental modal spectral acceleration is lower.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
25.00%
发文量
11
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信