{"title":"计算断层扫描、锥束计算机断层扫描和磁共振成像中钛、锆和二元钛锆基台的人工制品","authors":"H. Fakhar, H. Sharifian, Mahdi Niknami, Mahboobeh Iranmanesh","doi":"10.22038/JDMT.2020.44020.1317","DOIUrl":null,"url":null,"abstract":"Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scanned 4 times by each imaging modality. Gray value of the images was evaluated in four determined regions adjacent to distal, mesial, buccal and lingual aspects of the implant as the region of interest (ROI) by two observers using image J software. Gray value differences (∆GV) between the control (fixture without abutment) and case images (fixture and each type of abutments) were calculated. Data evaluation was done by analysis of variance and Post Hoc tests.Results: In CBCT, ∆GV was significantly higher in zirconium-titanium images comparing with titanium abutments. (P Value < 0.05)In distal, mesial and buccal aspects of ROI in CT, ∆GV was higher in zirconium images comparing with titanium abutments.In MRI, ∆GV for zirconium were lower than titanium-zirconium and titanium samples, respectively. Also, no significant differences in ∆GV were seen between T1 and T2 protocols, for all samples. Conclusion: In MRI, image artifacts are the least around Zirconium abutments, while in CT and CBCT, titanium abutments produced the least amount of artifacts.","PeriodicalId":15640,"journal":{"name":"Journal of Dental Materials and Techniques","volume":"59 1","pages":"10-14"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Artifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging\",\"authors\":\"H. Fakhar, H. Sharifian, Mahdi Niknami, Mahboobeh Iranmanesh\",\"doi\":\"10.22038/JDMT.2020.44020.1317\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scanned 4 times by each imaging modality. Gray value of the images was evaluated in four determined regions adjacent to distal, mesial, buccal and lingual aspects of the implant as the region of interest (ROI) by two observers using image J software. Gray value differences (∆GV) between the control (fixture without abutment) and case images (fixture and each type of abutments) were calculated. Data evaluation was done by analysis of variance and Post Hoc tests.Results: In CBCT, ∆GV was significantly higher in zirconium-titanium images comparing with titanium abutments. (P Value < 0.05)In distal, mesial and buccal aspects of ROI in CT, ∆GV was higher in zirconium images comparing with titanium abutments.In MRI, ∆GV for zirconium were lower than titanium-zirconium and titanium samples, respectively. Also, no significant differences in ∆GV were seen between T1 and T2 protocols, for all samples. Conclusion: In MRI, image artifacts are the least around Zirconium abutments, while in CT and CBCT, titanium abutments produced the least amount of artifacts.\",\"PeriodicalId\":15640,\"journal\":{\"name\":\"Journal of Dental Materials and Techniques\",\"volume\":\"59 1\",\"pages\":\"10-14\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Dental Materials and Techniques\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22038/JDMT.2020.44020.1317\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Materials and Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/JDMT.2020.44020.1317","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目的:探讨钛、锆、钛-锆基牙在CT、MRI和CBCT成像方式下的成像伪影。方法:将4×8mm钛支架置入干燥的人下颌骨。钛、锆和钛锆基台的高度为10.5 mm,一个接一个地位于夹具上。每个基牙采用每种成像方式扫描4次。图像的灰度值由两名观察者使用image J软件在种植体的远端、中端、颊部和舌部邻近的四个确定区域作为感兴趣区域(ROI)进行评估。计算控制图像(无基台的夹具)和案例图像(夹具和每种类型的基台)之间的灰度值差(∆GV)。通过方差分析和事后检验对数据进行评价。结果:CBCT中,锆钛基牙的∆GV明显高于钛基牙。(P值< 0.05)在远端、中端和颊部CT上,锆基牙的∆GV高于钛基牙。在MRI上,锆样品的∆GV分别低于钛锆样品和钛样品。此外,对于所有样本,T1和T2方案之间的∆GV没有显着差异。结论:在MRI上,锆基牙周围的伪影最少,而在CT和CBCT上,钛基牙周围的伪影最少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Artifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging
Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scanned 4 times by each imaging modality. Gray value of the images was evaluated in four determined regions adjacent to distal, mesial, buccal and lingual aspects of the implant as the region of interest (ROI) by two observers using image J software. Gray value differences (∆GV) between the control (fixture without abutment) and case images (fixture and each type of abutments) were calculated. Data evaluation was done by analysis of variance and Post Hoc tests.Results: In CBCT, ∆GV was significantly higher in zirconium-titanium images comparing with titanium abutments. (P Value < 0.05)In distal, mesial and buccal aspects of ROI in CT, ∆GV was higher in zirconium images comparing with titanium abutments.In MRI, ∆GV for zirconium were lower than titanium-zirconium and titanium samples, respectively. Also, no significant differences in ∆GV were seen between T1 and T2 protocols, for all samples. Conclusion: In MRI, image artifacts are the least around Zirconium abutments, while in CT and CBCT, titanium abutments produced the least amount of artifacts.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信