{"title":"非饱和运行下IaaS云的能耗特征","authors":"Haleh Khojasteh, J. Misic, V. Mišić","doi":"10.1109/INFCOMW.2014.6849265","DOIUrl":null,"url":null,"abstract":"To save energy, physical machines (servers) in cloud data centers are partitioned in different pools, depending on whether they are kept on at all times and/or whether they have virtual machines instantiated. Partitioning (pooling) of servers affects the power consumption of the data center but also the performance and responsiveness to user requests. In this paper we examine the behavior of pool management scheme in different operating regions which correspond to linear operation, transition to saturation, and saturation, in particular the tradeoff between performance and power consumption. In addition, our results show that the offered load (analogous to the concept often used in networking) does not offer complete characterization of data center operation; instead, the impact of task arrival rate and task service time must be considered separately.","PeriodicalId":6468,"journal":{"name":"2014 IEEE Conference on Computer Communications Workshops (INFOCOM WKSHPS)","volume":"39 5","pages":"398-403"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Characterizing energy consumption of IaaS clouds in non-saturated operation\",\"authors\":\"Haleh Khojasteh, J. Misic, V. Mišić\",\"doi\":\"10.1109/INFCOMW.2014.6849265\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To save energy, physical machines (servers) in cloud data centers are partitioned in different pools, depending on whether they are kept on at all times and/or whether they have virtual machines instantiated. Partitioning (pooling) of servers affects the power consumption of the data center but also the performance and responsiveness to user requests. In this paper we examine the behavior of pool management scheme in different operating regions which correspond to linear operation, transition to saturation, and saturation, in particular the tradeoff between performance and power consumption. In addition, our results show that the offered load (analogous to the concept often used in networking) does not offer complete characterization of data center operation; instead, the impact of task arrival rate and task service time must be considered separately.\",\"PeriodicalId\":6468,\"journal\":{\"name\":\"2014 IEEE Conference on Computer Communications Workshops (INFOCOM WKSHPS)\",\"volume\":\"39 5\",\"pages\":\"398-403\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-07-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Conference on Computer Communications Workshops (INFOCOM WKSHPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INFCOMW.2014.6849265\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Conference on Computer Communications Workshops (INFOCOM WKSHPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INFCOMW.2014.6849265","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

为了节省能源,云数据中心中的物理机器(服务器)在不同的池中进行了分区,这取决于它们是否一直处于开启状态和/或它们是否实例化了虚拟机。服务器的分区(池)不仅会影响数据中心的功耗,还会影响性能和对用户请求的响应。在本文中,我们研究了池管理方案在不同操作区域的行为,这些区域对应于线性操作,过渡到饱和和饱和,特别是性能和功耗之间的权衡。此外,我们的结果表明,提供的负载(类似于网络中经常使用的概念)并不能提供数据中心操作的完整特征;相反,必须分别考虑任务到达率和任务服务时间的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Characterizing energy consumption of IaaS clouds in non-saturated operation
To save energy, physical machines (servers) in cloud data centers are partitioned in different pools, depending on whether they are kept on at all times and/or whether they have virtual machines instantiated. Partitioning (pooling) of servers affects the power consumption of the data center but also the performance and responsiveness to user requests. In this paper we examine the behavior of pool management scheme in different operating regions which correspond to linear operation, transition to saturation, and saturation, in particular the tradeoff between performance and power consumption. In addition, our results show that the offered load (analogous to the concept often used in networking) does not offer complete characterization of data center operation; instead, the impact of task arrival rate and task service time must be considered separately.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信