{"title":"手性掺杂剂螺旋扭力的精确测量","authors":"T. Kósa, V. Bodnar, B. Taheri, P. Palffy-Muhoray","doi":"10.1080/10587250108030015","DOIUrl":null,"url":null,"abstract":"Abstract We report on an accurate measurement of the helical twisting power (HTP) of chiral dopants. In the usual Cano-wedge method, the wedge angle is determined from the separation of laser beams reflected from the windows of the test cell. Here we propose to use an optical fiber based spectrometer to accurately measure the call thickness instead. Knowing the cell thickness at the positions of the disclination lines allows evaluation of the HTP. We show that this extension of the Cano-wedge method greatly increases the accuracy with which the HTP is determined. We have applied this technique to determine the HTP of ZLI811 in a variety of hosts with negative dielectric anisotropy.","PeriodicalId":18940,"journal":{"name":"Molecular Crystals and Liquid Crystals Science and Technology. Section A. Molecular Crystals and Liquid Crystals","volume":"109 1","pages":"129 - 137"},"PeriodicalIF":0.0000,"publicationDate":"2001-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/10587250108030015","citationCount":"19","resultStr":"{\"title\":\"Accurate Measurement of the Helical Twisting Power of Chiral Dopants\",\"authors\":\"T. Kósa, V. Bodnar, B. Taheri, P. Palffy-Muhoray\",\"doi\":\"10.1080/10587250108030015\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract We report on an accurate measurement of the helical twisting power (HTP) of chiral dopants. In the usual Cano-wedge method, the wedge angle is determined from the separation of laser beams reflected from the windows of the test cell. Here we propose to use an optical fiber based spectrometer to accurately measure the call thickness instead. Knowing the cell thickness at the positions of the disclination lines allows evaluation of the HTP. We show that this extension of the Cano-wedge method greatly increases the accuracy with which the HTP is determined. We have applied this technique to determine the HTP of ZLI811 in a variety of hosts with negative dielectric anisotropy.\",\"PeriodicalId\":18940,\"journal\":{\"name\":\"Molecular Crystals and Liquid Crystals Science and Technology. Section A. Molecular Crystals and Liquid Crystals\",\"volume\":\"109 1\",\"pages\":\"129 - 137\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/10587250108030015\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Molecular Crystals and Liquid Crystals Science and Technology. Section A. Molecular Crystals and Liquid Crystals\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/10587250108030015\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Molecular Crystals and Liquid Crystals Science and Technology. Section A. Molecular Crystals and Liquid Crystals","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10587250108030015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

摘要

摘要本文报道了一种精确测量手性掺杂剂螺旋扭转力(HTP)的方法。在通常的Cano-wedge方法中,楔形角是由从测试单元窗口反射的激光束的距离确定的。在此,我们建议使用光纤光谱仪来精确测量呼叫厚度。知道在倾斜线的位置的细胞厚度允许评估HTP。我们表明,这种扩展的卡诺-楔法大大提高了确定HTP的精度。我们应用该技术测定了ZLI811在各种负介电各向异性介质中的HTP。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accurate Measurement of the Helical Twisting Power of Chiral Dopants
Abstract We report on an accurate measurement of the helical twisting power (HTP) of chiral dopants. In the usual Cano-wedge method, the wedge angle is determined from the separation of laser beams reflected from the windows of the test cell. Here we propose to use an optical fiber based spectrometer to accurately measure the call thickness instead. Knowing the cell thickness at the positions of the disclination lines allows evaluation of the HTP. We show that this extension of the Cano-wedge method greatly increases the accuracy with which the HTP is determined. We have applied this technique to determine the HTP of ZLI811 in a variety of hosts with negative dielectric anisotropy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信