Ludovic Labat , Michel Grisel , Joël Breard , Guy Bouquet
{"title":"由于复合材料的注射条件,原来使用电导率进行空隙检测","authors":"Ludovic Labat , Michel Grisel , Joël Breard , Guy Bouquet","doi":"10.1016/S1620-7742(01)01363-0","DOIUrl":null,"url":null,"abstract":"<div><p>The void defects present in composite parts are due to air entrapped during the injection process. We propose to use electrical conductivity measurements of the liquid to detect these defects. The saturation rate of the resin is measured as a function of time. Thanks to several sensors, placed along the mould, we are able to plot the resin front profile evolution versus the position. This method is a step forward in our knowledge of the parameter range for which no void is observed at the end of the injection.</p></div>","PeriodicalId":100302,"journal":{"name":"Comptes Rendus de l'Académie des Sciences - Series IIB - Mechanics","volume":"329 7","pages":"Pages 529-534"},"PeriodicalIF":0.0000,"publicationDate":"2001-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S1620-7742(01)01363-0","citationCount":"20","resultStr":"{\"title\":\"Original use of electrical conductivity for void detection due to injection conditions of composite materials\",\"authors\":\"Ludovic Labat , Michel Grisel , Joël Breard , Guy Bouquet\",\"doi\":\"10.1016/S1620-7742(01)01363-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The void defects present in composite parts are due to air entrapped during the injection process. We propose to use electrical conductivity measurements of the liquid to detect these defects. The saturation rate of the resin is measured as a function of time. Thanks to several sensors, placed along the mould, we are able to plot the resin front profile evolution versus the position. This method is a step forward in our knowledge of the parameter range for which no void is observed at the end of the injection.</p></div>\",\"PeriodicalId\":100302,\"journal\":{\"name\":\"Comptes Rendus de l'Académie des Sciences - Series IIB - Mechanics\",\"volume\":\"329 7\",\"pages\":\"Pages 529-534\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S1620-7742(01)01363-0\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Comptes Rendus de l'Académie des Sciences - Series IIB - Mechanics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1620774201013630\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Comptes Rendus de l'Académie des Sciences - Series IIB - Mechanics","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1620774201013630","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Original use of electrical conductivity for void detection due to injection conditions of composite materials
The void defects present in composite parts are due to air entrapped during the injection process. We propose to use electrical conductivity measurements of the liquid to detect these defects. The saturation rate of the resin is measured as a function of time. Thanks to several sensors, placed along the mould, we are able to plot the resin front profile evolution versus the position. This method is a step forward in our knowledge of the parameter range for which no void is observed at the end of the injection.