一次与两次釉料烧制对具有外部特征的整体cad-cam二硅酸锂玻璃陶瓷的颜色稳定性和机械性能的评估。

IF 3.4 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Aghata Kelma Palacio Gomes Magalhães, Gabriela Barros Moreira, Matheus Loíky Sampaio de Souza, Andrea Whitehurst Ary Leitão, Raniel Fernandes Peixoto, Cássio Pontes, Karina Matthes de Freitas Pontes
{"title":"一次与两次釉料烧制对具有外部特征的整体cad-cam二硅酸锂玻璃陶瓷的颜色稳定性和机械性能的评估。","authors":"Aghata Kelma Palacio Gomes Magalhães, Gabriela Barros Moreira, Matheus Loíky Sampaio de Souza, Andrea Whitehurst Ary Leitão, Raniel Fernandes Peixoto, Cássio Pontes, Karina Matthes de Freitas Pontes","doi":"10.1111/jopr.13792","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effects of 1 versus 2 glaze firings on the color and mechanical properties of an extrinsically characterized lithium disilicate ceramic after thermal cycling, brushing, or both.</p><p><strong>Materials and methods: </strong>Eighty specimens were divided into 2 groups: 1 glaze firing (GL1) and 2 glaze firings (GL2). Each group was subdivided into 4 groups (n = 10), according to the experimental conditions: thermal-cycling, brushing, thermal-cycling + brushing, and immersion in distilled water (control). Color variation, surface roughness, and Vickers microhardness were analyzed before each designated experiment and after the simulated periods of 2.5, 5, and 10 years. Three-way mixed ANOVA was used for all outcomes, followed by 1-way ANOVA, repeated measures 1-way ANOVA, Bonferroni post hoc test, and t-test to check for statistical differences (α = 0.05).</p><p><strong>Results: </strong>Thermal cycling generated greater color changes in the GL1 group at 2.5 and 5 years (p < 0.001; p = 0.013). Brushing generated color changes in GL1 at 5 years (p = 0.003) and in GL2 at 10 years (p = 0.017). Regarding surface roughness, the GL1 group suffered alterations in thermal cycling + brushing at 5 years. In the control group, the GL1 group exhibited higher roughness values than GL2 (p < 0.05). Most of the groups experienced an increase in microhardness at 2.5 years (p < 0.05). In the GL1 group, thermal-cycling increased the microhardness at 5 years (p = 0.006); at 5 and 10 years, the GL1 group had a higher microhardness than the GL2 in thermal-cycling + brushing (p < 0.05).</p><p><strong>Conclusion: </strong>Ceramics with 1 glaze firing showed greater color, roughness, and microhardness changes compared to those submitted to 2 firings.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":" ","pages":"33-41"},"PeriodicalIF":3.4000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of one versus two glaze firings on the color stability and mechanical properties of an extrinsically characterized monolithic CAD-CAM lithium disilicate glass ceramic.\",\"authors\":\"Aghata Kelma Palacio Gomes Magalhães, Gabriela Barros Moreira, Matheus Loíky Sampaio de Souza, Andrea Whitehurst Ary Leitão, Raniel Fernandes Peixoto, Cássio Pontes, Karina Matthes de Freitas Pontes\",\"doi\":\"10.1111/jopr.13792\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the effects of 1 versus 2 glaze firings on the color and mechanical properties of an extrinsically characterized lithium disilicate ceramic after thermal cycling, brushing, or both.</p><p><strong>Materials and methods: </strong>Eighty specimens were divided into 2 groups: 1 glaze firing (GL1) and 2 glaze firings (GL2). Each group was subdivided into 4 groups (n = 10), according to the experimental conditions: thermal-cycling, brushing, thermal-cycling + brushing, and immersion in distilled water (control). Color variation, surface roughness, and Vickers microhardness were analyzed before each designated experiment and after the simulated periods of 2.5, 5, and 10 years. Three-way mixed ANOVA was used for all outcomes, followed by 1-way ANOVA, repeated measures 1-way ANOVA, Bonferroni post hoc test, and t-test to check for statistical differences (α = 0.05).</p><p><strong>Results: </strong>Thermal cycling generated greater color changes in the GL1 group at 2.5 and 5 years (p < 0.001; p = 0.013). Brushing generated color changes in GL1 at 5 years (p = 0.003) and in GL2 at 10 years (p = 0.017). Regarding surface roughness, the GL1 group suffered alterations in thermal cycling + brushing at 5 years. In the control group, the GL1 group exhibited higher roughness values than GL2 (p < 0.05). Most of the groups experienced an increase in microhardness at 2.5 years (p < 0.05). In the GL1 group, thermal-cycling increased the microhardness at 5 years (p = 0.006); at 5 and 10 years, the GL1 group had a higher microhardness than the GL2 in thermal-cycling + brushing (p < 0.05).</p><p><strong>Conclusion: </strong>Ceramics with 1 glaze firing showed greater color, roughness, and microhardness changes compared to those submitted to 2 firings.</p>\",\"PeriodicalId\":49152,\"journal\":{\"name\":\"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry\",\"volume\":\" \",\"pages\":\"33-41\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/jopr.13792\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.13792","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/27 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估在热循环、刷涂或两者兼有后,1次和2次烧釉对外部表征的二硅酸锂陶瓷的颜色和机械性能的影响。材料与方法:将80个试件分为两组:一次烧成釉(GL1)和两次烧成釉料(GL2)。根据实验条件,每组分为4组(n=10):热循环、刷牙、热循环+刷牙和浸泡在蒸馏水中(对照)。在每次指定实验之前以及2.5年、5年和10年的模拟周期之后,分析颜色变化、表面粗糙度和维氏显微硬度。所有结果均使用三元混合方差分析,然后是单向方差分析、重复测量单向方差分析和Bonferroni事后检验,和t检验以检查统计差异(α=.05)。结果:热循环在2.5年和5年时GL1组产生了更大的颜色变化(P结论:与两次烧制相比,一次烧制的陶瓷表现出更大的色彩、粗糙度和显微硬度变化。本文受版权保护。保留所有权利。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of one versus two glaze firings on the color stability and mechanical properties of an extrinsically characterized monolithic CAD-CAM lithium disilicate glass ceramic.

Purpose: To evaluate the effects of 1 versus 2 glaze firings on the color and mechanical properties of an extrinsically characterized lithium disilicate ceramic after thermal cycling, brushing, or both.

Materials and methods: Eighty specimens were divided into 2 groups: 1 glaze firing (GL1) and 2 glaze firings (GL2). Each group was subdivided into 4 groups (n = 10), according to the experimental conditions: thermal-cycling, brushing, thermal-cycling + brushing, and immersion in distilled water (control). Color variation, surface roughness, and Vickers microhardness were analyzed before each designated experiment and after the simulated periods of 2.5, 5, and 10 years. Three-way mixed ANOVA was used for all outcomes, followed by 1-way ANOVA, repeated measures 1-way ANOVA, Bonferroni post hoc test, and t-test to check for statistical differences (α = 0.05).

Results: Thermal cycling generated greater color changes in the GL1 group at 2.5 and 5 years (p < 0.001; p = 0.013). Brushing generated color changes in GL1 at 5 years (p = 0.003) and in GL2 at 10 years (p = 0.017). Regarding surface roughness, the GL1 group suffered alterations in thermal cycling + brushing at 5 years. In the control group, the GL1 group exhibited higher roughness values than GL2 (p < 0.05). Most of the groups experienced an increase in microhardness at 2.5 years (p < 0.05). In the GL1 group, thermal-cycling increased the microhardness at 5 years (p = 0.006); at 5 and 10 years, the GL1 group had a higher microhardness than the GL2 in thermal-cycling + brushing (p < 0.05).

Conclusion: Ceramics with 1 glaze firing showed greater color, roughness, and microhardness changes compared to those submitted to 2 firings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信