义齿清洁剂对含二氧化钛纳米颗粒义齿基托材料颜色稳定性和表面性能的影响。

IF 3.4 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Elham Ansarifard, Mina Mohaghegh, Mohammad Hossein Saadat, Masumeh Taghva
{"title":"义齿清洁剂对含二氧化钛纳米颗粒义齿基托材料颜色稳定性和表面性能的影响。","authors":"Elham Ansarifard, Mina Mohaghegh, Mohammad Hossein Saadat, Masumeh Taghva","doi":"10.1111/jopr.13793","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the effect of different denture cleansers on color stability, surface roughness, and hardness of polymethylmethacrylate (PMMA) infused with titanium dioxide nanoparticles (TiO<sub>2</sub> NPs) at concentrations of 1% and 2% by weight on each.</p><p><strong>Materials and methods: </strong>In this in vitro study, 90 disc-shaped specimens (10×10×2 mm) were divided into 3 main groups: the non-containing nanoparticle group (0wt% concentration), 1wt% concentration, and 2wt% concentration TiO<sub>2</sub> NPs groups. Each group was further assorted into 3 subgroups (n = 10): immersed in distilled water, oxygenating tablet (Corega), and 0.5% sodium hypochlorite. Color change, surface roughness, and hardness values were assessed after 90 and 180 days of storage. Color changes (∆E) were measured with a spectrophotometer (VITA, Easy Shade V, Germany) and assessed using the CIE L*a*b* colorimetric system and the American National Bureau of Standards (NBS = 0.92×∆E). The surface roughness and surface hardness values were measured using a profilometer device and Vickers hardness tester, respectively. First, ANOVA-repeated measurements were performed, followed by the Tukey test. The significance level in this study was considered 0.05.</p><p><strong>Results: </strong>At all concentrations, there were significant differences in the mean color changes of samples immersed in cleansers compared to distilled water (p < 0.01). Moreover, hypochlorite caused a significant increase compared to Corega at 0wt% concentration after 90 days and at 1wt% concentration after 90 and 180 days. Evaluations also showed that the mean NBS values in all cleanser groups were in the range of appreciable change, except the water group. In addition, only hypochlorite changed the color higher than the clinically acceptable range (∆E >3.7). The mean roughness of samples immersed in hypochlorite at 0wt% concentration was significantly higher than the samples containing TiO<sub>2</sub> NPs (p = 0.006). No significant difference was observed in surface roughness of samples containing different concentrations of TiO<sub>2</sub> NPs immersed in different cleansers; however, hypochlorite increased the surface roughness of samples without TiO<sub>2</sub> NPs compared to samples containing TiO<sub>2</sub> NPs after 180 days. The immersion time in cleansers had a significant influence on the surface roughness and hardness while having no effect on the color.</p><p><strong>Conclusion: </strong>In general, the cleansers had a significant effect on color change in all groups compared to distilled water. The adverse effect of hypochlorite was more than Corega. The cleansers in the samples containing TiO<sub>2</sub> NPs did not make a significant difference in surface roughness in comparison with the distilled water groups. Surface hardness of the samples was not affected in a steady pattern by the cleansers.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":" ","pages":"49-57"},"PeriodicalIF":3.4000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of denture cleansers on color stability and surface properties of denture base material containing titanium dioxide nanoparticles.\",\"authors\":\"Elham Ansarifard, Mina Mohaghegh, Mohammad Hossein Saadat, Masumeh Taghva\",\"doi\":\"10.1111/jopr.13793\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To investigate the effect of different denture cleansers on color stability, surface roughness, and hardness of polymethylmethacrylate (PMMA) infused with titanium dioxide nanoparticles (TiO<sub>2</sub> NPs) at concentrations of 1% and 2% by weight on each.</p><p><strong>Materials and methods: </strong>In this in vitro study, 90 disc-shaped specimens (10×10×2 mm) were divided into 3 main groups: the non-containing nanoparticle group (0wt% concentration), 1wt% concentration, and 2wt% concentration TiO<sub>2</sub> NPs groups. Each group was further assorted into 3 subgroups (n = 10): immersed in distilled water, oxygenating tablet (Corega), and 0.5% sodium hypochlorite. Color change, surface roughness, and hardness values were assessed after 90 and 180 days of storage. Color changes (∆E) were measured with a spectrophotometer (VITA, Easy Shade V, Germany) and assessed using the CIE L*a*b* colorimetric system and the American National Bureau of Standards (NBS = 0.92×∆E). The surface roughness and surface hardness values were measured using a profilometer device and Vickers hardness tester, respectively. First, ANOVA-repeated measurements were performed, followed by the Tukey test. The significance level in this study was considered 0.05.</p><p><strong>Results: </strong>At all concentrations, there were significant differences in the mean color changes of samples immersed in cleansers compared to distilled water (p < 0.01). Moreover, hypochlorite caused a significant increase compared to Corega at 0wt% concentration after 90 days and at 1wt% concentration after 90 and 180 days. Evaluations also showed that the mean NBS values in all cleanser groups were in the range of appreciable change, except the water group. In addition, only hypochlorite changed the color higher than the clinically acceptable range (∆E >3.7). The mean roughness of samples immersed in hypochlorite at 0wt% concentration was significantly higher than the samples containing TiO<sub>2</sub> NPs (p = 0.006). No significant difference was observed in surface roughness of samples containing different concentrations of TiO<sub>2</sub> NPs immersed in different cleansers; however, hypochlorite increased the surface roughness of samples without TiO<sub>2</sub> NPs compared to samples containing TiO<sub>2</sub> NPs after 180 days. The immersion time in cleansers had a significant influence on the surface roughness and hardness while having no effect on the color.</p><p><strong>Conclusion: </strong>In general, the cleansers had a significant effect on color change in all groups compared to distilled water. The adverse effect of hypochlorite was more than Corega. The cleansers in the samples containing TiO<sub>2</sub> NPs did not make a significant difference in surface roughness in comparison with the distilled water groups. Surface hardness of the samples was not affected in a steady pattern by the cleansers.</p>\",\"PeriodicalId\":49152,\"journal\":{\"name\":\"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry\",\"volume\":\" \",\"pages\":\"49-57\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/jopr.13793\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.13793","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究不同义齿清洁剂对浓度分别为1%和2%(重量)的二氧化钛纳米粒子注入的聚甲基丙烯酸甲酯(PMMA)的颜色稳定性、表面粗糙度和硬度的影响。材料与方法:将90个10×10×2mm的圆盘状标本分为3组;不含纳米颗粒组(0wt%浓度)、1wt%浓度和2wt%浓度的TiO2 NP组。每组进一步分为3个亚组(n=10):浸泡在蒸馏水中、充氧片(Corega)和0.5%次氯酸钠中。储存90天和180天后评估颜色变化、表面粗糙度和硬度值。用分光光度计(VITA,Easy Shade V,德国)测量颜色变化(∆E),并使用CIE L*a*b*比色系统和美国国家标准局(NBS=0.92×∆E。首先,进行方差分析重复测量,然后进行Tukey检验。结果:在所有浓度下,与蒸馏水相比,浸泡在清洁剂中的样品的平均颜色变化存在显著差异(第3.7页)。在0wt%浓度下浸泡在次氯酸盐中的样品平均粗糙度显著高于含有TiO2 NP的样品(p=0.006)。含有不同浓度TiO2的样品表面粗糙度没有观察到显著差异浸泡在不同清洁剂中的NP;然而,与含有TiO2 NP的样品相比,次氯酸盐在180天后增加了没有TiO2 NP的样本的表面粗糙度。浸泡在清洁剂中的时间对表面粗糙度和硬度有显著影响,而对颜色没有影响。结论:总的来说,与蒸馏水相比,所有组的清洁剂都有显著的颜色变化。次氯酸盐的不良反应大于Corega。与蒸馏水组相比,含有TiO2 NP的样品中的清洁剂在表面粗糙度方面没有显著差异。样品的表面硬度没有受到清洁剂的稳定影响。这篇文章受版权保护。保留所有权利。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of denture cleansers on color stability and surface properties of denture base material containing titanium dioxide nanoparticles.

Purpose: To investigate the effect of different denture cleansers on color stability, surface roughness, and hardness of polymethylmethacrylate (PMMA) infused with titanium dioxide nanoparticles (TiO2 NPs) at concentrations of 1% and 2% by weight on each.

Materials and methods: In this in vitro study, 90 disc-shaped specimens (10×10×2 mm) were divided into 3 main groups: the non-containing nanoparticle group (0wt% concentration), 1wt% concentration, and 2wt% concentration TiO2 NPs groups. Each group was further assorted into 3 subgroups (n = 10): immersed in distilled water, oxygenating tablet (Corega), and 0.5% sodium hypochlorite. Color change, surface roughness, and hardness values were assessed after 90 and 180 days of storage. Color changes (∆E) were measured with a spectrophotometer (VITA, Easy Shade V, Germany) and assessed using the CIE L*a*b* colorimetric system and the American National Bureau of Standards (NBS = 0.92×∆E). The surface roughness and surface hardness values were measured using a profilometer device and Vickers hardness tester, respectively. First, ANOVA-repeated measurements were performed, followed by the Tukey test. The significance level in this study was considered 0.05.

Results: At all concentrations, there were significant differences in the mean color changes of samples immersed in cleansers compared to distilled water (p < 0.01). Moreover, hypochlorite caused a significant increase compared to Corega at 0wt% concentration after 90 days and at 1wt% concentration after 90 and 180 days. Evaluations also showed that the mean NBS values in all cleanser groups were in the range of appreciable change, except the water group. In addition, only hypochlorite changed the color higher than the clinically acceptable range (∆E >3.7). The mean roughness of samples immersed in hypochlorite at 0wt% concentration was significantly higher than the samples containing TiO2 NPs (p = 0.006). No significant difference was observed in surface roughness of samples containing different concentrations of TiO2 NPs immersed in different cleansers; however, hypochlorite increased the surface roughness of samples without TiO2 NPs compared to samples containing TiO2 NPs after 180 days. The immersion time in cleansers had a significant influence on the surface roughness and hardness while having no effect on the color.

Conclusion: In general, the cleansers had a significant effect on color change in all groups compared to distilled water. The adverse effect of hypochlorite was more than Corega. The cleansers in the samples containing TiO2 NPs did not make a significant difference in surface roughness in comparison with the distilled water groups. Surface hardness of the samples was not affected in a steady pattern by the cleansers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信