Kevin Kooi, Monica M Shoji, Jesse B Jupiter, Neal C Chen, Rohit Garg
{"title":"DRUJ前臂旋转受限的囊膜松解术:外科技术和病例系列。","authors":"Kevin Kooi, Monica M Shoji, Jesse B Jupiter, Neal C Chen, Rohit Garg","doi":"10.1177/15589447231207911","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Forearm stiffness can be caused by distal radioulnar joint (DRUJ) capsular contractures, which can occur after trauma such as a distal radius fracture. In this setting, a DRUJ capsular release may help improve forearm rotation, but the long-term functional outcomes remain unknown. The purpose of this case series is to investigate the short-term improvement in total pronosupination arc range of motion and long-term patient-reported outcomes (PROs) after DRUJ capsular release.</p><p><strong>Methods: </strong>We performed a retrospective review of consecutive patients who underwent DRUJ capsular release. Range of motion prior to surgery and at final short-term follow-up was collected and analyzed with a Wilcoxon signed-rank test. Patient-reported outcomes including QuickDASH and Patient-Reported Outcomes Measurement Information System (PROMIS) Upper Extremity (UE) scores were obtained as medians with interquartile range (IQR), while patient satisfaction was measured on a 4-point Likert scale.</p><p><strong>Results: </strong>Five patients met the inclusion criteria with a median short-term follow-up of 5.5 (IQR: 4.3-10.3) months. The median preoperative supination was 25° (IQR: 0°-35°), and the median postoperative supination was 50° (IQR: 40°-60°; <i>P</i> = .03). The median preoperative pronation was 45° (IQR: 10°-60°), and the median postoperative pronation was 70° (IQR: 60°-80°; <i>P</i> = .04). After the long-term median follow-up of 10.9 (IQR 9.7-11.2) years, all the patients were satisfied or very satisfied with the results of the surgery. The median QuickDASH score was 13.6 (IQR: 9.1-20.5), and the median PROMIS UE score was 46.5 (IQR: 43.8-47.7).</p><p><strong>Conclusions: </strong>Distal radioulnar joint capsular release can improve pronation and supination in patients with posttraumatic forearm stiffness and is associated with high long-term patient satisfaction.</p>","PeriodicalId":12902,"journal":{"name":"HAND","volume":" ","pages":"380-386"},"PeriodicalIF":1.8000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12093022/pdf/","citationCount":"0","resultStr":"{\"title\":\"DRUJ Capsular Release for Forearm Rotational Limitation: Surgical Technique and Case Series.\",\"authors\":\"Kevin Kooi, Monica M Shoji, Jesse B Jupiter, Neal C Chen, Rohit Garg\",\"doi\":\"10.1177/15589447231207911\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Forearm stiffness can be caused by distal radioulnar joint (DRUJ) capsular contractures, which can occur after trauma such as a distal radius fracture. In this setting, a DRUJ capsular release may help improve forearm rotation, but the long-term functional outcomes remain unknown. The purpose of this case series is to investigate the short-term improvement in total pronosupination arc range of motion and long-term patient-reported outcomes (PROs) after DRUJ capsular release.</p><p><strong>Methods: </strong>We performed a retrospective review of consecutive patients who underwent DRUJ capsular release. Range of motion prior to surgery and at final short-term follow-up was collected and analyzed with a Wilcoxon signed-rank test. Patient-reported outcomes including QuickDASH and Patient-Reported Outcomes Measurement Information System (PROMIS) Upper Extremity (UE) scores were obtained as medians with interquartile range (IQR), while patient satisfaction was measured on a 4-point Likert scale.</p><p><strong>Results: </strong>Five patients met the inclusion criteria with a median short-term follow-up of 5.5 (IQR: 4.3-10.3) months. The median preoperative supination was 25° (IQR: 0°-35°), and the median postoperative supination was 50° (IQR: 40°-60°; <i>P</i> = .03). The median preoperative pronation was 45° (IQR: 10°-60°), and the median postoperative pronation was 70° (IQR: 60°-80°; <i>P</i> = .04). After the long-term median follow-up of 10.9 (IQR 9.7-11.2) years, all the patients were satisfied or very satisfied with the results of the surgery. The median QuickDASH score was 13.6 (IQR: 9.1-20.5), and the median PROMIS UE score was 46.5 (IQR: 43.8-47.7).</p><p><strong>Conclusions: </strong>Distal radioulnar joint capsular release can improve pronation and supination in patients with posttraumatic forearm stiffness and is associated with high long-term patient satisfaction.</p>\",\"PeriodicalId\":12902,\"journal\":{\"name\":\"HAND\",\"volume\":\" \",\"pages\":\"380-386\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12093022/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"HAND\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/15589447231207911\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"HAND","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15589447231207911","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/9 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
DRUJ Capsular Release for Forearm Rotational Limitation: Surgical Technique and Case Series.
Background: Forearm stiffness can be caused by distal radioulnar joint (DRUJ) capsular contractures, which can occur after trauma such as a distal radius fracture. In this setting, a DRUJ capsular release may help improve forearm rotation, but the long-term functional outcomes remain unknown. The purpose of this case series is to investigate the short-term improvement in total pronosupination arc range of motion and long-term patient-reported outcomes (PROs) after DRUJ capsular release.
Methods: We performed a retrospective review of consecutive patients who underwent DRUJ capsular release. Range of motion prior to surgery and at final short-term follow-up was collected and analyzed with a Wilcoxon signed-rank test. Patient-reported outcomes including QuickDASH and Patient-Reported Outcomes Measurement Information System (PROMIS) Upper Extremity (UE) scores were obtained as medians with interquartile range (IQR), while patient satisfaction was measured on a 4-point Likert scale.
Results: Five patients met the inclusion criteria with a median short-term follow-up of 5.5 (IQR: 4.3-10.3) months. The median preoperative supination was 25° (IQR: 0°-35°), and the median postoperative supination was 50° (IQR: 40°-60°; P = .03). The median preoperative pronation was 45° (IQR: 10°-60°), and the median postoperative pronation was 70° (IQR: 60°-80°; P = .04). After the long-term median follow-up of 10.9 (IQR 9.7-11.2) years, all the patients were satisfied or very satisfied with the results of the surgery. The median QuickDASH score was 13.6 (IQR: 9.1-20.5), and the median PROMIS UE score was 46.5 (IQR: 43.8-47.7).
Conclusions: Distal radioulnar joint capsular release can improve pronation and supination in patients with posttraumatic forearm stiffness and is associated with high long-term patient satisfaction.
期刊介绍:
HAND is the official journal of the American Association for Hand Surgery and is a peer-reviewed journal featuring articles written by clinicians worldwide presenting current research and clinical work in the field of hand surgery. It features articles related to all aspects of hand and upper extremity surgery and the post operative care and rehabilitation of the hand.