广义犬传递函数准确地重建中央主动脉压力波形,以实现增强的脉搏波分析。

IF 1.3 4区 医学 Q4 PHARMACOLOGY & PHARMACY
Julia C. Hotek , Theodore J. Detwiler , Julio A. Chirinos , Christopher P. Regan
{"title":"广义犬传递函数准确地重建中央主动脉压力波形,以实现增强的脉搏波分析。","authors":"Julia C. Hotek ,&nbsp;Theodore J. Detwiler ,&nbsp;Julio A. Chirinos ,&nbsp;Christopher P. Regan","doi":"10.1016/j.vascn.2023.107476","DOIUrl":null,"url":null,"abstract":"<div><p>Routine preclinical blood pressure evaluation is an important risk assessment tool. Although proximal aortic pressure is most relevant for key target organs, abdominal aortic pressures are more commonly recorded. Pulse pressure amplification and waveform distortion in abdominal waveforms make it inappropriate for central hemodynamic analytical methods without the use of a mathematical transfer function. Clinical transfer functions have been developed to estimate ascending aortic waveforms from brachial or radial artery waveforms in humans, but no preclinical analogues exist. The aim of this study was to develop a canine-specific transfer function to reconstruct thoracic aortic pressure waveforms from abdominal aortic data to enable the application of central hemodynamic analytical methods. Simultaneous abdominal and thoracic blood pressures were recorded from seven conscious, male beagle dogs administered 3 well-characterized pharmacologic standards and animals were appointed to a training (<em>n</em> = 3) or validation (<em>n</em> = 4) group at baseline and during dosing. A generalized transfer function was developed from the training group data and evaluated for its ability to synthesize thoracic pressure waves in the training and validation groups. Select hemodynamic parameters were evaluated in measured and synthesized thoracic data. There was a high degree of correlation between measured and synthesized thoracic parameters (r<sup>2</sup> = 0.74–0.99). There was no difference between indices computed from synthesized or actual thoracic waveforms at baseline or after administration of pharmacologic standards. This work demonstrates that a generalized preclinical transfer function can reproduce thoracic pressure waves across a range of hemodynamic responses thus enabling the application of central hemodynamic analytical methods.</p></div>","PeriodicalId":16767,"journal":{"name":"Journal of pharmacological and toxicological methods","volume":"124 ","pages":"Article 107476"},"PeriodicalIF":1.3000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1056871923002277/pdfft?md5=eb8c079434afbad68e40f41bae182312&pid=1-s2.0-S1056871923002277-main.pdf","citationCount":"0","resultStr":"{\"title\":\"A generalized canine transfer function accurately reconstructs central aortic pressure waveforms to enable enhanced pulse wave analysis\",\"authors\":\"Julia C. Hotek ,&nbsp;Theodore J. Detwiler ,&nbsp;Julio A. Chirinos ,&nbsp;Christopher P. Regan\",\"doi\":\"10.1016/j.vascn.2023.107476\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Routine preclinical blood pressure evaluation is an important risk assessment tool. Although proximal aortic pressure is most relevant for key target organs, abdominal aortic pressures are more commonly recorded. Pulse pressure amplification and waveform distortion in abdominal waveforms make it inappropriate for central hemodynamic analytical methods without the use of a mathematical transfer function. Clinical transfer functions have been developed to estimate ascending aortic waveforms from brachial or radial artery waveforms in humans, but no preclinical analogues exist. The aim of this study was to develop a canine-specific transfer function to reconstruct thoracic aortic pressure waveforms from abdominal aortic data to enable the application of central hemodynamic analytical methods. Simultaneous abdominal and thoracic blood pressures were recorded from seven conscious, male beagle dogs administered 3 well-characterized pharmacologic standards and animals were appointed to a training (<em>n</em> = 3) or validation (<em>n</em> = 4) group at baseline and during dosing. A generalized transfer function was developed from the training group data and evaluated for its ability to synthesize thoracic pressure waves in the training and validation groups. Select hemodynamic parameters were evaluated in measured and synthesized thoracic data. There was a high degree of correlation between measured and synthesized thoracic parameters (r<sup>2</sup> = 0.74–0.99). There was no difference between indices computed from synthesized or actual thoracic waveforms at baseline or after administration of pharmacologic standards. This work demonstrates that a generalized preclinical transfer function can reproduce thoracic pressure waves across a range of hemodynamic responses thus enabling the application of central hemodynamic analytical methods.</p></div>\",\"PeriodicalId\":16767,\"journal\":{\"name\":\"Journal of pharmacological and toxicological methods\",\"volume\":\"124 \",\"pages\":\"Article 107476\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1056871923002277/pdfft?md5=eb8c079434afbad68e40f41bae182312&pid=1-s2.0-S1056871923002277-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of pharmacological and toxicological methods\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1056871923002277\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmacological and toxicological methods","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1056871923002277","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

摘要

常规临床前血压评估是一种重要的风险评估工具。尽管近端主动脉压力与关键靶器官最相关,但腹主动脉压力更常见。腹部波形中的脉压放大和波形失真使其不适合不使用数学传递函数的中央血液动力学分析方法。临床传递函数已被开发用于从人类的肱动脉或桡动脉波形估计升主动脉波形,但不存在临床前类似物。本研究的目的是开发一种犬特异性传递函数,从腹主动脉数据重建胸主动脉压力波形,从而能够应用中央血液动力学分析方法。同时记录了7只清醒的雄性比格犬的腹部和胸部血压,这些犬接受了良好的药理学标准,并接受了训练(n = 3) 或验证(n = 4) 组在基线和给药期间使用3种药理学标准。根据训练组的数据开发了一个广义传递函数,并在训练组和验证组中评估了其合成胸廓压力波的能力。在测量和合成的胸部数据中评估选定的血液动力学参数。测量的胸部参数和合成的胸部参数之间存在高度相关性(r2 = 0.74-0.99)。根据基线或给药药物标准后的合成或实际胸部波形计算的指标之间没有差异。这项工作表明,广义的临床前传递函数可以在一系列血液动力学反应中重现胸廓压力波,从而能够应用中央血液动力学分析方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A generalized canine transfer function accurately reconstructs central aortic pressure waveforms to enable enhanced pulse wave analysis

Routine preclinical blood pressure evaluation is an important risk assessment tool. Although proximal aortic pressure is most relevant for key target organs, abdominal aortic pressures are more commonly recorded. Pulse pressure amplification and waveform distortion in abdominal waveforms make it inappropriate for central hemodynamic analytical methods without the use of a mathematical transfer function. Clinical transfer functions have been developed to estimate ascending aortic waveforms from brachial or radial artery waveforms in humans, but no preclinical analogues exist. The aim of this study was to develop a canine-specific transfer function to reconstruct thoracic aortic pressure waveforms from abdominal aortic data to enable the application of central hemodynamic analytical methods. Simultaneous abdominal and thoracic blood pressures were recorded from seven conscious, male beagle dogs administered 3 well-characterized pharmacologic standards and animals were appointed to a training (n = 3) or validation (n = 4) group at baseline and during dosing. A generalized transfer function was developed from the training group data and evaluated for its ability to synthesize thoracic pressure waves in the training and validation groups. Select hemodynamic parameters were evaluated in measured and synthesized thoracic data. There was a high degree of correlation between measured and synthesized thoracic parameters (r2 = 0.74–0.99). There was no difference between indices computed from synthesized or actual thoracic waveforms at baseline or after administration of pharmacologic standards. This work demonstrates that a generalized preclinical transfer function can reproduce thoracic pressure waves across a range of hemodynamic responses thus enabling the application of central hemodynamic analytical methods.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of pharmacological and toxicological methods
Journal of pharmacological and toxicological methods PHARMACOLOGY & PHARMACY-TOXICOLOGY
CiteScore
3.60
自引率
10.50%
发文量
56
审稿时长
26 days
期刊介绍: Journal of Pharmacological and Toxicological Methods publishes original articles on current methods of investigation used in pharmacology and toxicology. Pharmacology and toxicology are defined in the broadest sense, referring to actions of drugs and chemicals on all living systems. With its international editorial board and noted contributors, Journal of Pharmacological and Toxicological Methods is the leading journal devoted exclusively to experimental procedures used by pharmacologists and toxicologists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信