内部生产的177Lu放射性药物和市售Luthathera®中177mLu浓度的评估。

IF 4.4 Q1 CHEMISTRY, INORGANIC & NUCLEAR
Matthias Balzer, Fleur Spiecker, Stephanie Bluemel, Holger Amthauer, Winfried Brenner, Sarah Spreckelmeyer
{"title":"内部生产的177Lu放射性药物和市售Luthathera®中177mLu浓度的评估。","authors":"Matthias Balzer,&nbsp;Fleur Spiecker,&nbsp;Stephanie Bluemel,&nbsp;Holger Amthauer,&nbsp;Winfried Brenner,&nbsp;Sarah Spreckelmeyer","doi":"10.1186/s41181-023-00222-2","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p><sup>177</sup>Lu-radiopharmaceuticals can contain the metastable impurity [<sup>177m</sup>Lu]lutetium with a physical half-life of 160.4 days, in varying concentrations depending on the route of production of the radionuclidic precursor [<sup>177</sup>Lu]lutetium. Due to the long half-life of [<sup>177m</sup>Lu]lutetium, difficulties with waste disposal or sterility testing could arise. Here, we analyzed several <sup>177</sup>Lu-samples of different origins and suppliers regarding their <sup>177m</sup>Lu-concentration.</p><h3>Results</h3><p>All samples tested showed a <sup>177m</sup>Lu-concentration in the range that was stated on the certificate of analysis from the supplier which is in accordance with the European Pharmacopoeia.</p><h3>Conclusions</h3><p>Although all <sup>177m</sup>Lu-concentrations were in accordance with the European Pharmacopoeia, we need to take into account the respective national legislation regarding radioactivity release limits. With regard to the German legislation, several probes for sterility testing in external laboratories could not be released for transport due to the concentration of [<sup>177m</sup>Lu]lutetium. Moreover, waste water tanks should specifically be monitored for <sup>177m</sup>Lu-concentration, when e.g. Lutathera<sup>®</sup> is administered in the clinic.</p></div>","PeriodicalId":534,"journal":{"name":"EJNMMI Radiopharmacy and Chemistry","volume":null,"pages":null},"PeriodicalIF":4.4000,"publicationDate":"2023-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10628054/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the 177mLu-concentration in in-house produced 177Lu-radiopharmaceuticals and commercially available Lutathera®\",\"authors\":\"Matthias Balzer,&nbsp;Fleur Spiecker,&nbsp;Stephanie Bluemel,&nbsp;Holger Amthauer,&nbsp;Winfried Brenner,&nbsp;Sarah Spreckelmeyer\",\"doi\":\"10.1186/s41181-023-00222-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p><sup>177</sup>Lu-radiopharmaceuticals can contain the metastable impurity [<sup>177m</sup>Lu]lutetium with a physical half-life of 160.4 days, in varying concentrations depending on the route of production of the radionuclidic precursor [<sup>177</sup>Lu]lutetium. Due to the long half-life of [<sup>177m</sup>Lu]lutetium, difficulties with waste disposal or sterility testing could arise. Here, we analyzed several <sup>177</sup>Lu-samples of different origins and suppliers regarding their <sup>177m</sup>Lu-concentration.</p><h3>Results</h3><p>All samples tested showed a <sup>177m</sup>Lu-concentration in the range that was stated on the certificate of analysis from the supplier which is in accordance with the European Pharmacopoeia.</p><h3>Conclusions</h3><p>Although all <sup>177m</sup>Lu-concentrations were in accordance with the European Pharmacopoeia, we need to take into account the respective national legislation regarding radioactivity release limits. With regard to the German legislation, several probes for sterility testing in external laboratories could not be released for transport due to the concentration of [<sup>177m</sup>Lu]lutetium. Moreover, waste water tanks should specifically be monitored for <sup>177m</sup>Lu-concentration, when e.g. Lutathera<sup>®</sup> is administered in the clinic.</p></div>\",\"PeriodicalId\":534,\"journal\":{\"name\":\"EJNMMI Radiopharmacy and Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.4000,\"publicationDate\":\"2023-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10628054/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EJNMMI Radiopharmacy and Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://link.springer.com/article/10.1186/s41181-023-00222-2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, INORGANIC & NUCLEAR\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Radiopharmacy and Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s41181-023-00222-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

摘要

背景:177Lu放射性药物可能含有物理半衰期为160.4天的亚稳态杂质[177mLu]镥,其浓度不同,取决于放射性核素前体[177Lu]镥的生产途径。由于[177mLu]镥的半衰期较长,可能会出现废物处理或无菌检测方面的困难。在这里我们分析了几个不同来源和供应商的177Lu样品的177mLu浓度。结果:所有测试样品的177mL u浓度均在供应商的分析证书上规定的范围内,该证书符合《欧洲药典》,我们需要考虑到各国关于放射性释放限制的立法。关于德国立法,由于[177mLu]镥的浓度,在外部实验室进行无菌检测的几种探针无法放行运输。此外,当在诊所使用Luthathera®时,应特别监测废水罐的177毫升u浓度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Evaluation of the 177mLu-concentration in in-house produced 177Lu-radiopharmaceuticals and commercially available Lutathera®

Evaluation of the 177mLu-concentration in in-house produced 177Lu-radiopharmaceuticals and commercially available Lutathera®

Evaluation of the 177mLu-concentration in in-house produced 177Lu-radiopharmaceuticals and commercially available Lutathera®

Evaluation of the 177mLu-concentration in in-house produced 177Lu-radiopharmaceuticals and commercially available Lutathera®

Background

177Lu-radiopharmaceuticals can contain the metastable impurity [177mLu]lutetium with a physical half-life of 160.4 days, in varying concentrations depending on the route of production of the radionuclidic precursor [177Lu]lutetium. Due to the long half-life of [177mLu]lutetium, difficulties with waste disposal or sterility testing could arise. Here, we analyzed several 177Lu-samples of different origins and suppliers regarding their 177mLu-concentration.

Results

All samples tested showed a 177mLu-concentration in the range that was stated on the certificate of analysis from the supplier which is in accordance with the European Pharmacopoeia.

Conclusions

Although all 177mLu-concentrations were in accordance with the European Pharmacopoeia, we need to take into account the respective national legislation regarding radioactivity release limits. With regard to the German legislation, several probes for sterility testing in external laboratories could not be released for transport due to the concentration of [177mLu]lutetium. Moreover, waste water tanks should specifically be monitored for 177mLu-concentration, when e.g. Lutathera® is administered in the clinic.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.20
自引率
8.70%
发文量
30
审稿时长
5 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信