用全面的自我追踪支持妊娠期糖尿病的管理:可穿戴传感器的混合方法研究。

Q2 Medicine
JMIR Diabetes Pub Date : 2023-10-31 DOI:10.2196/43979
Mikko Kytö, Saila Koivusalo, Heli Tuomonen, Lisbeth Strömberg, Antti Ruonala, Pekka Marttinen, Seppo Heinonen, Giulio Jacucci
{"title":"用全面的自我追踪支持妊娠期糖尿病的管理:可穿戴传感器的混合方法研究。","authors":"Mikko Kytö, Saila Koivusalo, Heli Tuomonen, Lisbeth Strömberg, Antti Ruonala, Pekka Marttinen, Seppo Heinonen, Giulio Jacucci","doi":"10.2196/43979","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Gestational diabetes mellitus (GDM) is an increasing health risk for pregnant women as well as their children. Telehealth interventions targeted at the management of GDM have been shown to be effective, but they still require health care professionals for providing guidance and feedback. Feedback from wearable sensors has been suggested to support the self-management of GDM, but it is unknown how self-tracking should be designed in clinical care.</p><p><strong>Objective: </strong>This study aimed to investigate how to support the self-management of GDM with self-tracking of continuous blood glucose and lifestyle factors without help from health care personnel. We examined comprehensive self-tracking from self-discovery (ie, learning associations between glucose levels and lifestyle) and user experience perspectives.</p><p><strong>Methods: </strong>We conducted a mixed methods study where women with GDM (N=10) used a continuous glucose monitor (CGM; Medtronic Guardian) and 3 physical activity sensors: activity bracelet (Garmin Vivosmart 3), hip-worn sensor (UKK Exsed), and electrocardiography sensor (Firstbeat 2) for a week. We collected data from the sensors, and after use, participants took part in semistructured interviews about the wearable sensors. Acceptability of the wearable sensors was evaluated with the Unified Theory of Acceptance and Use of Technology (UTAUT) questionnaire. Moreover, maternal nutrition data were collected with a 3-day food diary, and self-reported physical activity data were collected with a logbook.</p><p><strong>Results: </strong>We found that the CGM was the most useful sensor for the self-discovery process, especially when learning associations between glucose and nutrition intake. We identified new challenges for using data from the CGM and physical activity sensors in supporting self-discovery in GDM. These challenges included (1) dispersion of glucose and physical activity data in separate applications, (2) absence of important trackable features like amount of light physical activity and physical activities other than walking, (3) discrepancy in the data between different wearable physical activity sensors and between CGMs and capillary glucose meters, and (4) discrepancy in perceived and measured quantification of physical activity. We found the body placement of sensors to be a key factor in measurement quality and preference, and ultimately a challenge for collecting data. For example, a wrist-worn sensor was used for longer compared with a hip-worn sensor. In general, there was a high acceptance for wearable sensors.</p><p><strong>Conclusions: </strong>A mobile app that combines glucose, nutrition, and physical activity data in a single view is needed to support self-discovery. The design should support tracking features that are important for women with GDM (such as light physical activity), and data for each feature should originate from a single sensor to avoid discrepancy and redundancy. Future work with a larger sample should involve evaluation of the effects of such a mobile app on clinical outcomes.</p><p><strong>Trial registration: </strong>Clinicaltrials.gov NCT03941652; https://clinicaltrials.gov/study/NCT03941652.</p>","PeriodicalId":52371,"journal":{"name":"JMIR Diabetes","volume":"8 ","pages":"e43979"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10646680/pdf/","citationCount":"0","resultStr":"{\"title\":\"Supporting the Management of Gestational Diabetes Mellitus With Comprehensive Self-Tracking: Mixed Methods Study of Wearable Sensors.\",\"authors\":\"Mikko Kytö, Saila Koivusalo, Heli Tuomonen, Lisbeth Strömberg, Antti Ruonala, Pekka Marttinen, Seppo Heinonen, Giulio Jacucci\",\"doi\":\"10.2196/43979\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Gestational diabetes mellitus (GDM) is an increasing health risk for pregnant women as well as their children. Telehealth interventions targeted at the management of GDM have been shown to be effective, but they still require health care professionals for providing guidance and feedback. Feedback from wearable sensors has been suggested to support the self-management of GDM, but it is unknown how self-tracking should be designed in clinical care.</p><p><strong>Objective: </strong>This study aimed to investigate how to support the self-management of GDM with self-tracking of continuous blood glucose and lifestyle factors without help from health care personnel. We examined comprehensive self-tracking from self-discovery (ie, learning associations between glucose levels and lifestyle) and user experience perspectives.</p><p><strong>Methods: </strong>We conducted a mixed methods study where women with GDM (N=10) used a continuous glucose monitor (CGM; Medtronic Guardian) and 3 physical activity sensors: activity bracelet (Garmin Vivosmart 3), hip-worn sensor (UKK Exsed), and electrocardiography sensor (Firstbeat 2) for a week. We collected data from the sensors, and after use, participants took part in semistructured interviews about the wearable sensors. Acceptability of the wearable sensors was evaluated with the Unified Theory of Acceptance and Use of Technology (UTAUT) questionnaire. Moreover, maternal nutrition data were collected with a 3-day food diary, and self-reported physical activity data were collected with a logbook.</p><p><strong>Results: </strong>We found that the CGM was the most useful sensor for the self-discovery process, especially when learning associations between glucose and nutrition intake. We identified new challenges for using data from the CGM and physical activity sensors in supporting self-discovery in GDM. These challenges included (1) dispersion of glucose and physical activity data in separate applications, (2) absence of important trackable features like amount of light physical activity and physical activities other than walking, (3) discrepancy in the data between different wearable physical activity sensors and between CGMs and capillary glucose meters, and (4) discrepancy in perceived and measured quantification of physical activity. We found the body placement of sensors to be a key factor in measurement quality and preference, and ultimately a challenge for collecting data. For example, a wrist-worn sensor was used for longer compared with a hip-worn sensor. In general, there was a high acceptance for wearable sensors.</p><p><strong>Conclusions: </strong>A mobile app that combines glucose, nutrition, and physical activity data in a single view is needed to support self-discovery. The design should support tracking features that are important for women with GDM (such as light physical activity), and data for each feature should originate from a single sensor to avoid discrepancy and redundancy. Future work with a larger sample should involve evaluation of the effects of such a mobile app on clinical outcomes.</p><p><strong>Trial registration: </strong>Clinicaltrials.gov NCT03941652; https://clinicaltrials.gov/study/NCT03941652.</p>\",\"PeriodicalId\":52371,\"journal\":{\"name\":\"JMIR Diabetes\",\"volume\":\"8 \",\"pages\":\"e43979\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10646680/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JMIR Diabetes\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2196/43979\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JMIR Diabetes","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2196/43979","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景:妊娠期糖尿病(GDM)对孕妇及其子女的健康风险越来越大。针对GDM管理的远程医疗干预措施已被证明是有效的,但它们仍然需要卫生保健专业人员提供指导和反馈。来自可穿戴传感器的反馈已被建议支持GDM的自我管理,但尚不清楚在临床护理中应如何设计自我跟踪。目的:本研究旨在探讨如何在没有医护人员帮助的情况下,通过对持续血糖和生活方式因素的自我跟踪来支持GDM的自我管理。我们从自我发现(即血糖水平和生活方式之间的学习关联)和用户体验的角度研究了全面的自我跟踪。方法:我们进行了一项混合方法研究,患有GDM(N=10)的女性使用连续血糖监测仪(CGM;美敦力监护)和3种身体活动传感器:活动手环(Garmin Vivosmart 3)、髋关节佩戴传感器(UKK Exsed)和心电图传感器(Firstbeat 2),为期一周。我们从传感器中收集数据,使用后,参与者参加了关于可穿戴传感器的半结构访谈。采用技术接受和使用统一理论(UTAUT)问卷对可穿戴传感器的可接受性进行评估。此外,通过3天的饮食日记收集产妇营养数据,并通过日志收集自我报告的身体活动数据。结果:我们发现CGM是自我发现过程中最有用的传感器,尤其是在学习葡萄糖和营养摄入之间的关联时。我们发现了使用来自CGM和身体活动传感器的数据来支持GDM中的自我发现的新挑战。这些挑战包括(1)葡萄糖和体力活动数据在不同应用中的分散性,(2)缺乏重要的可跟踪特征,如光体力活动量和步行以外的体力活动,(3)不同可穿戴体力活动传感器之间以及CGM和毛细管血糖仪之间的数据差异,以及(4)身体活动的感知量化和测量量化的差异。我们发现传感器的身体位置是测量质量和偏好的关键因素,也是收集数据的最终挑战。例如,与髋关节佩戴的传感器相比,手腕佩戴的传感器使用时间更长。一般来说,可穿戴传感器的接受度很高。结论:需要一款将葡萄糖、营养和身体活动数据结合在一个视图中的移动应用程序来支持自我发现。该设计应支持对患有GDM的女性很重要的跟踪功能(如轻度体力活动),每个功能的数据应来自单个传感器,以避免差异和冗余。未来对更大样本的研究应该包括评估这种移动应用程序对临床结果的影响。试验注册:Clinicaltrials.gov NCT03941652;https://clinicaltrials.gov/study/NCT03941652.
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Supporting the Management of Gestational Diabetes Mellitus With Comprehensive Self-Tracking: Mixed Methods Study of Wearable Sensors.

Background: Gestational diabetes mellitus (GDM) is an increasing health risk for pregnant women as well as their children. Telehealth interventions targeted at the management of GDM have been shown to be effective, but they still require health care professionals for providing guidance and feedback. Feedback from wearable sensors has been suggested to support the self-management of GDM, but it is unknown how self-tracking should be designed in clinical care.

Objective: This study aimed to investigate how to support the self-management of GDM with self-tracking of continuous blood glucose and lifestyle factors without help from health care personnel. We examined comprehensive self-tracking from self-discovery (ie, learning associations between glucose levels and lifestyle) and user experience perspectives.

Methods: We conducted a mixed methods study where women with GDM (N=10) used a continuous glucose monitor (CGM; Medtronic Guardian) and 3 physical activity sensors: activity bracelet (Garmin Vivosmart 3), hip-worn sensor (UKK Exsed), and electrocardiography sensor (Firstbeat 2) for a week. We collected data from the sensors, and after use, participants took part in semistructured interviews about the wearable sensors. Acceptability of the wearable sensors was evaluated with the Unified Theory of Acceptance and Use of Technology (UTAUT) questionnaire. Moreover, maternal nutrition data were collected with a 3-day food diary, and self-reported physical activity data were collected with a logbook.

Results: We found that the CGM was the most useful sensor for the self-discovery process, especially when learning associations between glucose and nutrition intake. We identified new challenges for using data from the CGM and physical activity sensors in supporting self-discovery in GDM. These challenges included (1) dispersion of glucose and physical activity data in separate applications, (2) absence of important trackable features like amount of light physical activity and physical activities other than walking, (3) discrepancy in the data between different wearable physical activity sensors and between CGMs and capillary glucose meters, and (4) discrepancy in perceived and measured quantification of physical activity. We found the body placement of sensors to be a key factor in measurement quality and preference, and ultimately a challenge for collecting data. For example, a wrist-worn sensor was used for longer compared with a hip-worn sensor. In general, there was a high acceptance for wearable sensors.

Conclusions: A mobile app that combines glucose, nutrition, and physical activity data in a single view is needed to support self-discovery. The design should support tracking features that are important for women with GDM (such as light physical activity), and data for each feature should originate from a single sensor to avoid discrepancy and redundancy. Future work with a larger sample should involve evaluation of the effects of such a mobile app on clinical outcomes.

Trial registration: Clinicaltrials.gov NCT03941652; https://clinicaltrials.gov/study/NCT03941652.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
JMIR Diabetes
JMIR Diabetes Computer Science-Computer Science Applications
CiteScore
4.00
自引率
0.00%
发文量
35
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信