火电厂噪声分布分析及隔声措施

IF 0.2 Q4 ACOUSTICS
J. Yun, Won-Jin Kim
{"title":"火电厂噪声分布分析及隔声措施","authors":"J. Yun, Won-Jin Kim","doi":"10.7776/ASK.2020.39.2.105","DOIUrl":null,"url":null,"abstract":": An analysis model of noise map is proposed to evaluate and reduce the acoustical noise of power plant and its surroundings. The sound powers of many noise sources are estimated by measuring the sound levels of major equipments in the power plant. The analysis of noise has been made by using ENPro that is a commercial program for environmental noise prediction. The proposed model is verified by comparing the results from noise analysis and measurement at several points of the power plant units 1 through 4, and residential areas. It is shown that noise map simulation using the proposed model has a reliability, since the overall noise level approximates within the error of ±2 dB. Furthermore, through noise analysis, the increasing effect of noise due to newly established units 5 and 6 on residential areas is also analyzed. Consequently, the noise barrier is designed to meet an environmental noise standard and satisfy low cost and safety conditions.","PeriodicalId":42689,"journal":{"name":"Journal of the Acoustical Society of Korea","volume":"39 1","pages":"105-112"},"PeriodicalIF":0.2000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Noise distribution analysis and noise barrier measures of thermal power plant\",\"authors\":\"J. Yun, Won-Jin Kim\",\"doi\":\"10.7776/ASK.2020.39.2.105\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": An analysis model of noise map is proposed to evaluate and reduce the acoustical noise of power plant and its surroundings. The sound powers of many noise sources are estimated by measuring the sound levels of major equipments in the power plant. The analysis of noise has been made by using ENPro that is a commercial program for environmental noise prediction. The proposed model is verified by comparing the results from noise analysis and measurement at several points of the power plant units 1 through 4, and residential areas. It is shown that noise map simulation using the proposed model has a reliability, since the overall noise level approximates within the error of ±2 dB. Furthermore, through noise analysis, the increasing effect of noise due to newly established units 5 and 6 on residential areas is also analyzed. Consequently, the noise barrier is designed to meet an environmental noise standard and satisfy low cost and safety conditions.\",\"PeriodicalId\":42689,\"journal\":{\"name\":\"Journal of the Acoustical Society of Korea\",\"volume\":\"39 1\",\"pages\":\"105-112\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Acoustical Society of Korea\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7776/ASK.2020.39.2.105\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Acoustical Society of Korea","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7776/ASK.2020.39.2.105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Noise distribution analysis and noise barrier measures of thermal power plant
: An analysis model of noise map is proposed to evaluate and reduce the acoustical noise of power plant and its surroundings. The sound powers of many noise sources are estimated by measuring the sound levels of major equipments in the power plant. The analysis of noise has been made by using ENPro that is a commercial program for environmental noise prediction. The proposed model is verified by comparing the results from noise analysis and measurement at several points of the power plant units 1 through 4, and residential areas. It is shown that noise map simulation using the proposed model has a reliability, since the overall noise level approximates within the error of ±2 dB. Furthermore, through noise analysis, the increasing effect of noise due to newly established units 5 and 6 on residential areas is also analyzed. Consequently, the noise barrier is designed to meet an environmental noise standard and satisfy low cost and safety conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.60
自引率
50.00%
发文量
1
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信