{"title":"使用化学活性电极材料的伏安传感器","authors":"C. O. Huber","doi":"10.6028/jres.093.129","DOIUrl":null,"url":null,"abstract":"Voltammetric analytical techniques have ordinarily used relatively inert conducting materials in order to maximize the range of available applied potential and to enhance selectivity of the electrode reactions by control of applied potentials. A number of investigators have recently been examining modification of electrode surfaces in order to improve selectivity and sensitivity which are essential components to enhanced accuracy at trace levels. These modifications include bonded chemical functionalities, adsorption, polymers, use of electrode paste vehicle solubility, enzyme attachment and others. In the work reported here the use of several chemically active electrode materials is reported. In flow-through voltammetric devices, such as for HPLC and FIA detectors, the chemical history of the electrode surface is relatively easily managed so that sometimes chemically active electrode materials can offer advantages. Further, these onstream voltammetric configurations offer the advantages of controlled convection, electrode surface history, and ease of detector design. In this laboratory some recent studies exemplifying such an approach have involved nickel/nickel oxide [1-3], copper/copper oxide and silver iodide [4] as working electrode materials. Nickel electrodes have allowed the smooth oxidation of hydroxyl and amine as well as more easily oxidized organic functional groups. The typical electrode conditions include 0.1 M sodium hydroxide as electrolyte. Often 0.1 mM nickel sulfate is added to the electrolyte to enhance long-term activity to slower reacting analytes. Typically a flow rate of 1 mL/min and a sample injection volume of 25 FL is used. The anodic current is controlled by redox reaction rate of the electrodes higher oxide lattice sites with the analyte molecule. This allows for low concentration level determinations of sugars, alcohols, glycols, amino acids, proteins, nucleic acids and nucleic acid constituents. Although the carrier stream is alkaline, acidic samples can be readily accommodated using the flow injection technique. The low-pH sample plug first produces a cathodic component to the signal as part of the electrode oxide layer is reduced, but as the pH increases with the passing of the low-pH segment a fresh, high-activity oxide layer is produced which oxidizes the end of the sample plug. Samples with pH as low as two can be accommodated. Layers of nickel oxide adsorbed on metals other than nickel yielded similar reactions to those using a nickel substrate. Several proteins have been determined at concentrations as low as I mg/L [3]. Sensitivity is enhanced by increased temperature. Sideand end-hydroxyl and amino groups as well as sulfhydryl groups are oxidized, thus the technique is general for proteins, not limited to sulfide or bisulfide as for most electroanalytical methods, or to aromaticity as in UV-absorbance methods. Denaturation of human serum albumin in 0.1 M NaOH was followed by the technique. The results obtained correlate with a model based on random coil chain length control of denaturation rates interrupted by disulfide bond breakage delays. A series of alcohols and glycols was studied. The anodic reaction rates, i.e., anodic amperometric sensitivities, could be correlated to the electron withdrawing nature of the moiety bonded to the primary reactant methylene-ol (-CH2 OH) of the analyte. Rate constants vary by more than an order of magnitude from isopropanol to 1,2-propanediol. The linear range was more than two orders of magnitude, extending to lower detection limits of less than one micromolar. The nickel electrode work has been extended to HPLC detection for amino acids by post-column mixing of 0.2 M sodium hydroxide at a T connection with a 0.1 mmx 1.3 m mixing tube [2]. As predicted by hydrodynamic theory, no significant band broadening was observed. Consideration of Pourbaix diagrams indicates that cathodic pretreatment of a nickel electrode can generate a temporary high pH near the electrode surface. On stepping to anodic potentials a temporary anodic current for analytes should then be observed. Applying this approach resulted in the determination of ethanol in a pH 7 carrier solution with a linear response, a sensitivity of 3.3 iA/ mM and a lower detection limit of 0.8 mM. This relatively high limit was primarily due to high background current. Analytes subject to anodic determination at","PeriodicalId":17082,"journal":{"name":"Journal of research of the National Bureau of Standards","volume":"93 1","pages":"488 - 489"},"PeriodicalIF":0.0000,"publicationDate":"1988-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Voltammetric Sensors Using Chemically Active Electrode Materials\",\"authors\":\"C. O. Huber\",\"doi\":\"10.6028/jres.093.129\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Voltammetric analytical techniques have ordinarily used relatively inert conducting materials in order to maximize the range of available applied potential and to enhance selectivity of the electrode reactions by control of applied potentials. A number of investigators have recently been examining modification of electrode surfaces in order to improve selectivity and sensitivity which are essential components to enhanced accuracy at trace levels. These modifications include bonded chemical functionalities, adsorption, polymers, use of electrode paste vehicle solubility, enzyme attachment and others. In the work reported here the use of several chemically active electrode materials is reported. In flow-through voltammetric devices, such as for HPLC and FIA detectors, the chemical history of the electrode surface is relatively easily managed so that sometimes chemically active electrode materials can offer advantages. Further, these onstream voltammetric configurations offer the advantages of controlled convection, electrode surface history, and ease of detector design. In this laboratory some recent studies exemplifying such an approach have involved nickel/nickel oxide [1-3], copper/copper oxide and silver iodide [4] as working electrode materials. Nickel electrodes have allowed the smooth oxidation of hydroxyl and amine as well as more easily oxidized organic functional groups. The typical electrode conditions include 0.1 M sodium hydroxide as electrolyte. Often 0.1 mM nickel sulfate is added to the electrolyte to enhance long-term activity to slower reacting analytes. Typically a flow rate of 1 mL/min and a sample injection volume of 25 FL is used. The anodic current is controlled by redox reaction rate of the electrodes higher oxide lattice sites with the analyte molecule. This allows for low concentration level determinations of sugars, alcohols, glycols, amino acids, proteins, nucleic acids and nucleic acid constituents. Although the carrier stream is alkaline, acidic samples can be readily accommodated using the flow injection technique. The low-pH sample plug first produces a cathodic component to the signal as part of the electrode oxide layer is reduced, but as the pH increases with the passing of the low-pH segment a fresh, high-activity oxide layer is produced which oxidizes the end of the sample plug. Samples with pH as low as two can be accommodated. Layers of nickel oxide adsorbed on metals other than nickel yielded similar reactions to those using a nickel substrate. Several proteins have been determined at concentrations as low as I mg/L [3]. Sensitivity is enhanced by increased temperature. Sideand end-hydroxyl and amino groups as well as sulfhydryl groups are oxidized, thus the technique is general for proteins, not limited to sulfide or bisulfide as for most electroanalytical methods, or to aromaticity as in UV-absorbance methods. Denaturation of human serum albumin in 0.1 M NaOH was followed by the technique. The results obtained correlate with a model based on random coil chain length control of denaturation rates interrupted by disulfide bond breakage delays. A series of alcohols and glycols was studied. The anodic reaction rates, i.e., anodic amperometric sensitivities, could be correlated to the electron withdrawing nature of the moiety bonded to the primary reactant methylene-ol (-CH2 OH) of the analyte. Rate constants vary by more than an order of magnitude from isopropanol to 1,2-propanediol. The linear range was more than two orders of magnitude, extending to lower detection limits of less than one micromolar. The nickel electrode work has been extended to HPLC detection for amino acids by post-column mixing of 0.2 M sodium hydroxide at a T connection with a 0.1 mmx 1.3 m mixing tube [2]. As predicted by hydrodynamic theory, no significant band broadening was observed. Consideration of Pourbaix diagrams indicates that cathodic pretreatment of a nickel electrode can generate a temporary high pH near the electrode surface. On stepping to anodic potentials a temporary anodic current for analytes should then be observed. Applying this approach resulted in the determination of ethanol in a pH 7 carrier solution with a linear response, a sensitivity of 3.3 iA/ mM and a lower detection limit of 0.8 mM. This relatively high limit was primarily due to high background current. Analytes subject to anodic determination at\",\"PeriodicalId\":17082,\"journal\":{\"name\":\"Journal of research of the National Bureau of Standards\",\"volume\":\"93 1\",\"pages\":\"488 - 489\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of research of the National Bureau of Standards\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.6028/jres.093.129\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of research of the National Bureau of Standards","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6028/jres.093.129","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Voltammetric Sensors Using Chemically Active Electrode Materials
Voltammetric analytical techniques have ordinarily used relatively inert conducting materials in order to maximize the range of available applied potential and to enhance selectivity of the electrode reactions by control of applied potentials. A number of investigators have recently been examining modification of electrode surfaces in order to improve selectivity and sensitivity which are essential components to enhanced accuracy at trace levels. These modifications include bonded chemical functionalities, adsorption, polymers, use of electrode paste vehicle solubility, enzyme attachment and others. In the work reported here the use of several chemically active electrode materials is reported. In flow-through voltammetric devices, such as for HPLC and FIA detectors, the chemical history of the electrode surface is relatively easily managed so that sometimes chemically active electrode materials can offer advantages. Further, these onstream voltammetric configurations offer the advantages of controlled convection, electrode surface history, and ease of detector design. In this laboratory some recent studies exemplifying such an approach have involved nickel/nickel oxide [1-3], copper/copper oxide and silver iodide [4] as working electrode materials. Nickel electrodes have allowed the smooth oxidation of hydroxyl and amine as well as more easily oxidized organic functional groups. The typical electrode conditions include 0.1 M sodium hydroxide as electrolyte. Often 0.1 mM nickel sulfate is added to the electrolyte to enhance long-term activity to slower reacting analytes. Typically a flow rate of 1 mL/min and a sample injection volume of 25 FL is used. The anodic current is controlled by redox reaction rate of the electrodes higher oxide lattice sites with the analyte molecule. This allows for low concentration level determinations of sugars, alcohols, glycols, amino acids, proteins, nucleic acids and nucleic acid constituents. Although the carrier stream is alkaline, acidic samples can be readily accommodated using the flow injection technique. The low-pH sample plug first produces a cathodic component to the signal as part of the electrode oxide layer is reduced, but as the pH increases with the passing of the low-pH segment a fresh, high-activity oxide layer is produced which oxidizes the end of the sample plug. Samples with pH as low as two can be accommodated. Layers of nickel oxide adsorbed on metals other than nickel yielded similar reactions to those using a nickel substrate. Several proteins have been determined at concentrations as low as I mg/L [3]. Sensitivity is enhanced by increased temperature. Sideand end-hydroxyl and amino groups as well as sulfhydryl groups are oxidized, thus the technique is general for proteins, not limited to sulfide or bisulfide as for most electroanalytical methods, or to aromaticity as in UV-absorbance methods. Denaturation of human serum albumin in 0.1 M NaOH was followed by the technique. The results obtained correlate with a model based on random coil chain length control of denaturation rates interrupted by disulfide bond breakage delays. A series of alcohols and glycols was studied. The anodic reaction rates, i.e., anodic amperometric sensitivities, could be correlated to the electron withdrawing nature of the moiety bonded to the primary reactant methylene-ol (-CH2 OH) of the analyte. Rate constants vary by more than an order of magnitude from isopropanol to 1,2-propanediol. The linear range was more than two orders of magnitude, extending to lower detection limits of less than one micromolar. The nickel electrode work has been extended to HPLC detection for amino acids by post-column mixing of 0.2 M sodium hydroxide at a T connection with a 0.1 mmx 1.3 m mixing tube [2]. As predicted by hydrodynamic theory, no significant band broadening was observed. Consideration of Pourbaix diagrams indicates that cathodic pretreatment of a nickel electrode can generate a temporary high pH near the electrode surface. On stepping to anodic potentials a temporary anodic current for analytes should then be observed. Applying this approach resulted in the determination of ethanol in a pH 7 carrier solution with a linear response, a sensitivity of 3.3 iA/ mM and a lower detection limit of 0.8 mM. This relatively high limit was primarily due to high background current. Analytes subject to anodic determination at