两种锥束计算机断层多平面重建定向方案的比较

Vandana Kumar, D. Ang, K. Williams, M. Walker
{"title":"两种锥束计算机断层多平面重建定向方案的比较","authors":"Vandana Kumar, D. Ang, K. Williams, M. Walker","doi":"10.5430/JBGC.V3N2P7","DOIUrl":null,"url":null,"abstract":"Objective: The utilization of cone beam computed tomographic imaging for oral implants has increased enormously for precise determination of anatomic dimensions. However, the impact of reorientation of data that influences the constructed panoramic view and thus the measurements on generated cross sectional views has not been explored. This study is undertaken to explore if differences exist in the implant height and width measurement when the whole data is reoriented from the standard manufacturer's setting to an aligned protocol (perpendicular to the implant (XYZ) settings). Material and Methods: Two different orientation protocols were set up, standard and aligned or perpendicular setting (XYZ), and implant height and width measurements derived from these were compared to the original known measurements. Results: The range of differences between actual dimensions and measurements obtained using each orientation method using McNemar's Change test in the four accuracy categories (exact, +0.20, +0.25, and +0.50) showed the aligned orientation produced larger proportion of width measurements between +0.25 and +0.50 compared to standard for width measures; however, these differences were not statistically significant. Implant length measurements varied widely and this variability was irrespective of orientation method. Conclusions: The aligned/perpendicular (XYZ) protocol produces implant width measurements more accurate than length when compared to the standard protocol.","PeriodicalId":89580,"journal":{"name":"Journal of biomedical graphics and computing","volume":"3 1","pages":"7"},"PeriodicalIF":0.0000,"publicationDate":"2013-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5430/JBGC.V3N2P7","citationCount":"5","resultStr":"{\"title\":\"Comparison of two cone beam computed tomography multiplanar reconstruction orientation protocols\",\"authors\":\"Vandana Kumar, D. Ang, K. Williams, M. Walker\",\"doi\":\"10.5430/JBGC.V3N2P7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: The utilization of cone beam computed tomographic imaging for oral implants has increased enormously for precise determination of anatomic dimensions. However, the impact of reorientation of data that influences the constructed panoramic view and thus the measurements on generated cross sectional views has not been explored. This study is undertaken to explore if differences exist in the implant height and width measurement when the whole data is reoriented from the standard manufacturer's setting to an aligned protocol (perpendicular to the implant (XYZ) settings). Material and Methods: Two different orientation protocols were set up, standard and aligned or perpendicular setting (XYZ), and implant height and width measurements derived from these were compared to the original known measurements. Results: The range of differences between actual dimensions and measurements obtained using each orientation method using McNemar's Change test in the four accuracy categories (exact, +0.20, +0.25, and +0.50) showed the aligned orientation produced larger proportion of width measurements between +0.25 and +0.50 compared to standard for width measures; however, these differences were not statistically significant. Implant length measurements varied widely and this variability was irrespective of orientation method. Conclusions: The aligned/perpendicular (XYZ) protocol produces implant width measurements more accurate than length when compared to the standard protocol.\",\"PeriodicalId\":89580,\"journal\":{\"name\":\"Journal of biomedical graphics and computing\",\"volume\":\"3 1\",\"pages\":\"7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-02-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.5430/JBGC.V3N2P7\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of biomedical graphics and computing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5430/JBGC.V3N2P7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomedical graphics and computing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5430/JBGC.V3N2P7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

目的:锥形束计算机断层成像技术在口腔种植体解剖尺寸的精确测定中的应用日益广泛。然而,数据重新定向对构建的全景视图的影响以及对生成的截面视图的测量的影响尚未得到探讨。本研究旨在探索当所有数据从标准制造商设置重新定向到对齐协议(垂直于种植体(XYZ)设置)时,种植体高度和宽度测量是否存在差异。材料和方法:设置了两种不同的取向协议,标准和对齐或垂直设置(XYZ),并将由此得出的种植体高度和宽度测量值与原始已知测量值进行比较。结果:采用McNemar’s Change检验,在4个精度类别(精确、+0.20、+0.25、+0.50)下,各取向方法的实际尺寸与测量值之间的差异范围表明,与标准宽度测量值相比,对齐取向产生的+0.25 ~ +0.50之间的宽度测量值所占比例较大;然而,这些差异没有统计学意义。种植体长度测量变化很大,这种变化与取向方法无关。结论:与标准方案相比,对齐/垂直(XYZ)方案产生的种植体宽度测量比长度测量更准确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of two cone beam computed tomography multiplanar reconstruction orientation protocols
Objective: The utilization of cone beam computed tomographic imaging for oral implants has increased enormously for precise determination of anatomic dimensions. However, the impact of reorientation of data that influences the constructed panoramic view and thus the measurements on generated cross sectional views has not been explored. This study is undertaken to explore if differences exist in the implant height and width measurement when the whole data is reoriented from the standard manufacturer's setting to an aligned protocol (perpendicular to the implant (XYZ) settings). Material and Methods: Two different orientation protocols were set up, standard and aligned or perpendicular setting (XYZ), and implant height and width measurements derived from these were compared to the original known measurements. Results: The range of differences between actual dimensions and measurements obtained using each orientation method using McNemar's Change test in the four accuracy categories (exact, +0.20, +0.25, and +0.50) showed the aligned orientation produced larger proportion of width measurements between +0.25 and +0.50 compared to standard for width measures; however, these differences were not statistically significant. Implant length measurements varied widely and this variability was irrespective of orientation method. Conclusions: The aligned/perpendicular (XYZ) protocol produces implant width measurements more accurate than length when compared to the standard protocol.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信