输液中假丝酵母菌污染的快速检测

S. Oie, K. Kouda, H. Furukawa, A. Kamiya
{"title":"输液中假丝酵母菌污染的快速检测","authors":"S. Oie, K. Kouda, H. Furukawa, A. Kamiya","doi":"10.5430/CNS.V6N4P80","DOIUrl":null,"url":null,"abstract":"We encountered a case of microbial contamination of infusion fluid detected based on the discoloration of an inline filter (membrane filter) in the main route. A cause of this contamination may be the use of an extension tube connected to the main route for more than a month. In the infusion fluid above the inline filter (on the high calorie end), 2.4 × 105 colony forming units (cfu)/ml of Candida parapsilosis was detected. “Adenosine triphosphate (ATP) + adenosine monophosphate (AMP)” was determined in addition. We conclude that microbial contamination of this infusion fluid can be rapidly estimated by measuring the amounts of “ATP + AMP”.","PeriodicalId":72616,"journal":{"name":"Clinical nursing studies","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5430/CNS.V6N4P80","citationCount":"2","resultStr":"{\"title\":\"Rapid detection of Candida parapsilosis contamination in the infusion fluid\",\"authors\":\"S. Oie, K. Kouda, H. Furukawa, A. Kamiya\",\"doi\":\"10.5430/CNS.V6N4P80\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We encountered a case of microbial contamination of infusion fluid detected based on the discoloration of an inline filter (membrane filter) in the main route. A cause of this contamination may be the use of an extension tube connected to the main route for more than a month. In the infusion fluid above the inline filter (on the high calorie end), 2.4 × 105 colony forming units (cfu)/ml of Candida parapsilosis was detected. “Adenosine triphosphate (ATP) + adenosine monophosphate (AMP)” was determined in addition. We conclude that microbial contamination of this infusion fluid can be rapidly estimated by measuring the amounts of “ATP + AMP”.\",\"PeriodicalId\":72616,\"journal\":{\"name\":\"Clinical nursing studies\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.5430/CNS.V6N4P80\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical nursing studies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5430/CNS.V6N4P80\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical nursing studies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5430/CNS.V6N4P80","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

我们遇到了一个病例的微生物污染的输液检测基于在线过滤器(膜过滤器)的变色在主要路线。这种污染的一个原因可能是使用连接到主要路线的延伸管超过一个月。在在线过滤器上方(高热量端)的输液液中,检测到2.4 × 105菌落形成单位(cfu)/ml的假丝酵母。同时测定了三磷酸腺苷(ATP) +单磷酸腺苷(AMP)。我们得出结论,通过测量“ATP + AMP”的量可以快速估计输液液的微生物污染。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Rapid detection of Candida parapsilosis contamination in the infusion fluid
We encountered a case of microbial contamination of infusion fluid detected based on the discoloration of an inline filter (membrane filter) in the main route. A cause of this contamination may be the use of an extension tube connected to the main route for more than a month. In the infusion fluid above the inline filter (on the high calorie end), 2.4 × 105 colony forming units (cfu)/ml of Candida parapsilosis was detected. “Adenosine triphosphate (ATP) + adenosine monophosphate (AMP)” was determined in addition. We conclude that microbial contamination of this infusion fluid can be rapidly estimated by measuring the amounts of “ATP + AMP”.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信