预混硅酸钙基根管密封剂的不透光性

Q4 Dentistry
B. Dzeletovic, Ivana Milanović, Đorđe Antonijević, Jovan Badnjar, Zoran Petrov, Violeta Petrovic, N. Teodorović
{"title":"预混硅酸钙基根管密封剂的不透光性","authors":"B. Dzeletovic, Ivana Milanović, Đorđe Antonijević, Jovan Badnjar, Zoran Petrov, Violeta Petrovic, N. Teodorović","doi":"10.5937/asn2184256d","DOIUrl":null,"url":null,"abstract":"Background: Premixedcalcium silicate-based sealers are ready-to-use, injectable materials with advantageous biological properties that create environment favorable for periapical tissues repair and health. The aim of our study was to examine the radiopacities of premixed calcium silicate-based sealers:TotalFill BCSealer, EndoSequence BC Sealer, Ceraseal, Bio-C Sealer and to compare them with epoxy-basedsealer, AH Plus. Material and methods: Three specimens (2 mm thick and 5 mm in diameter) of each sealer were radiographed using charge-coupled device-baseddigital sensor (Trophy Radiology, Cedex, France) along with an aluminum stepwedge reference.For radiopacity determination, a graph of the logarithm of aluminum thickness versus radiographic density was plotted and a calibration curve was generated. Radiopacities were assessed from the graph and presented as millimeters of aluminum per millimeter of material (mmAl).ANOVA with a post hoc Tukey test was used for statistical analysis and significance was set at 0.05. Results: Radiopacity values of EndoSequence BC Sealer and Bio-C Sealerwere significantly lower than radiopacities of Ceraseal and AH Plus. Differences in values between EndoSequence BC Sealer and Bio-C Sealer as well as between Ceraseal and AH Plus were nonsignificant. TotalFill BC Sealer was nonsignificantly different from all other sealers. Conclusion: Premixed calcium silicate-based endodontic sealers evaluated in our study had radiopacity values higher than 9 mmAl, in ascending order,from Bio-C Sealer, EndoSequence BC Sealer, TotalFill BC Sealer to Ceraseal.","PeriodicalId":39229,"journal":{"name":"Acta Stomatologica Naissi","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Radiopacity of Premixed calcium silicate-based endodontic sealers\",\"authors\":\"B. Dzeletovic, Ivana Milanović, Đorđe Antonijević, Jovan Badnjar, Zoran Petrov, Violeta Petrovic, N. Teodorović\",\"doi\":\"10.5937/asn2184256d\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Premixedcalcium silicate-based sealers are ready-to-use, injectable materials with advantageous biological properties that create environment favorable for periapical tissues repair and health. The aim of our study was to examine the radiopacities of premixed calcium silicate-based sealers:TotalFill BCSealer, EndoSequence BC Sealer, Ceraseal, Bio-C Sealer and to compare them with epoxy-basedsealer, AH Plus. Material and methods: Three specimens (2 mm thick and 5 mm in diameter) of each sealer were radiographed using charge-coupled device-baseddigital sensor (Trophy Radiology, Cedex, France) along with an aluminum stepwedge reference.For radiopacity determination, a graph of the logarithm of aluminum thickness versus radiographic density was plotted and a calibration curve was generated. Radiopacities were assessed from the graph and presented as millimeters of aluminum per millimeter of material (mmAl).ANOVA with a post hoc Tukey test was used for statistical analysis and significance was set at 0.05. Results: Radiopacity values of EndoSequence BC Sealer and Bio-C Sealerwere significantly lower than radiopacities of Ceraseal and AH Plus. Differences in values between EndoSequence BC Sealer and Bio-C Sealer as well as between Ceraseal and AH Plus were nonsignificant. TotalFill BC Sealer was nonsignificantly different from all other sealers. Conclusion: Premixed calcium silicate-based endodontic sealers evaluated in our study had radiopacity values higher than 9 mmAl, in ascending order,from Bio-C Sealer, EndoSequence BC Sealer, TotalFill BC Sealer to Ceraseal.\",\"PeriodicalId\":39229,\"journal\":{\"name\":\"Acta Stomatologica Naissi\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Stomatologica Naissi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5937/asn2184256d\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Stomatologica Naissi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5937/asn2184256d","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

背景:预混硅酸钙基密封剂是一种即用型可注射材料,具有良好的生物特性,可为根尖周组织修复和健康创造有利的环境。我们研究的目的是检查预混硅酸钙基密封剂(TotalFill BCSealer, EndoSequence BCSealer, Ceraseal, Bio-C Sealer)的放射不透明,并将它们与环氧基密封剂AH Plus进行比较。材料和方法:使用基于电荷耦合器件的数字传感器(Trophy Radiology, Cedex,法国)对每个密封件的三个标本(2mm厚,5mm直径)进行x线摄影,并使用铝阶梯楔作为参考。为了确定射线不透明度,绘制了铝厚度对射线照相密度的对数图,并生成了校准曲线。从图中评估放射不透明度,并以每毫米材料的铝毫米(mmAl)表示。采用方差分析和事后Tukey检验进行统计分析,显著性为0.05。结果:EndoSequence BC Sealer和Bio-C Sealer的放射不透明值明显低于Ceraseal和AH Plus的放射不透明值。EndoSequence BC Sealer和Bio-C Sealer之间以及Ceraseal和AH Plus之间的值差异无统计学意义。TotalFill BC封口机与所有其他封口机无显著差异。结论:在我们的研究中评估的预混硅酸钙基根管密封剂的放射不透明度值高于9mal,从Bio-C密封剂、EndoSequence BC密封剂、TotalFill BC密封剂到Ceraseal。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Radiopacity of Premixed calcium silicate-based endodontic sealers
Background: Premixedcalcium silicate-based sealers are ready-to-use, injectable materials with advantageous biological properties that create environment favorable for periapical tissues repair and health. The aim of our study was to examine the radiopacities of premixed calcium silicate-based sealers:TotalFill BCSealer, EndoSequence BC Sealer, Ceraseal, Bio-C Sealer and to compare them with epoxy-basedsealer, AH Plus. Material and methods: Three specimens (2 mm thick and 5 mm in diameter) of each sealer were radiographed using charge-coupled device-baseddigital sensor (Trophy Radiology, Cedex, France) along with an aluminum stepwedge reference.For radiopacity determination, a graph of the logarithm of aluminum thickness versus radiographic density was plotted and a calibration curve was generated. Radiopacities were assessed from the graph and presented as millimeters of aluminum per millimeter of material (mmAl).ANOVA with a post hoc Tukey test was used for statistical analysis and significance was set at 0.05. Results: Radiopacity values of EndoSequence BC Sealer and Bio-C Sealerwere significantly lower than radiopacities of Ceraseal and AH Plus. Differences in values between EndoSequence BC Sealer and Bio-C Sealer as well as between Ceraseal and AH Plus were nonsignificant. TotalFill BC Sealer was nonsignificantly different from all other sealers. Conclusion: Premixed calcium silicate-based endodontic sealers evaluated in our study had radiopacity values higher than 9 mmAl, in ascending order,from Bio-C Sealer, EndoSequence BC Sealer, TotalFill BC Sealer to Ceraseal.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Stomatologica Naissi
Acta Stomatologica Naissi Dentistry-Dentistry (all)
CiteScore
0.10
自引率
0.00%
发文量
0
审稿时长
4 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信