M. Castejon, Rosemeire Yamashiro, Carmem Aparecida F. Oliveira, E. Mata, L. Brigido, M. Guimarães, M. Veras
{"title":"艾滋病毒感染诊断检测的性能评价","authors":"M. Castejon, Rosemeire Yamashiro, Carmem Aparecida F. Oliveira, E. Mata, L. Brigido, M. Guimarães, M. Veras","doi":"10.5935/1676-2444.20200024","DOIUrl":null,"url":null,"abstract":"Introduction: Many factors can impact the performance of diagnostic assays for the human immunodeficiency virus (HIV) infection, affecting the results of population surveys. Objective: The objective of this study was to evaluate the performance of point-of-care rapid tests (RT) used for HIV diagnosis as compared to conventional tests in blood samples from a population of transvestites and transsexual women. Methods: A total of 1,385 samples with HIV RT results were submitted to Instituto Adolfo Lutz for evaluation by conventional laboratory tests. Results: HIV positivity was confirmed by conventional laboratory tests in 100% of the 240 (17.3%) samples with reactive RT. However, 1,145 (82.7%) samples with non-reactive RT results were evaluated; three (0.3%) tested positive and one (0.1%), indeterminate for HIV. Although a proportion of discordant results were found, the point-of-care RTs showed a high confirmation rate when compared to the serological tests. Conclusion: The data of this study corroborate the importance of adopting effective management tools to ensure quality of HIV infection diagnosis.","PeriodicalId":35397,"journal":{"name":"Jornal Brasileiro de Patologia e Medicina Laboratorial","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Performance evaluation of HIV infection diagnostic tests\",\"authors\":\"M. Castejon, Rosemeire Yamashiro, Carmem Aparecida F. Oliveira, E. Mata, L. Brigido, M. Guimarães, M. Veras\",\"doi\":\"10.5935/1676-2444.20200024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Many factors can impact the performance of diagnostic assays for the human immunodeficiency virus (HIV) infection, affecting the results of population surveys. Objective: The objective of this study was to evaluate the performance of point-of-care rapid tests (RT) used for HIV diagnosis as compared to conventional tests in blood samples from a population of transvestites and transsexual women. Methods: A total of 1,385 samples with HIV RT results were submitted to Instituto Adolfo Lutz for evaluation by conventional laboratory tests. Results: HIV positivity was confirmed by conventional laboratory tests in 100% of the 240 (17.3%) samples with reactive RT. However, 1,145 (82.7%) samples with non-reactive RT results were evaluated; three (0.3%) tested positive and one (0.1%), indeterminate for HIV. Although a proportion of discordant results were found, the point-of-care RTs showed a high confirmation rate when compared to the serological tests. Conclusion: The data of this study corroborate the importance of adopting effective management tools to ensure quality of HIV infection diagnosis.\",\"PeriodicalId\":35397,\"journal\":{\"name\":\"Jornal Brasileiro de Patologia e Medicina Laboratorial\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jornal Brasileiro de Patologia e Medicina Laboratorial\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5935/1676-2444.20200024\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jornal Brasileiro de Patologia e Medicina Laboratorial","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5935/1676-2444.20200024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
Performance evaluation of HIV infection diagnostic tests
Introduction: Many factors can impact the performance of diagnostic assays for the human immunodeficiency virus (HIV) infection, affecting the results of population surveys. Objective: The objective of this study was to evaluate the performance of point-of-care rapid tests (RT) used for HIV diagnosis as compared to conventional tests in blood samples from a population of transvestites and transsexual women. Methods: A total of 1,385 samples with HIV RT results were submitted to Instituto Adolfo Lutz for evaluation by conventional laboratory tests. Results: HIV positivity was confirmed by conventional laboratory tests in 100% of the 240 (17.3%) samples with reactive RT. However, 1,145 (82.7%) samples with non-reactive RT results were evaluated; three (0.3%) tested positive and one (0.1%), indeterminate for HIV. Although a proportion of discordant results were found, the point-of-care RTs showed a high confirmation rate when compared to the serological tests. Conclusion: The data of this study corroborate the importance of adopting effective management tools to ensure quality of HIV infection diagnosis.
期刊介绍:
The Jornal Brasileiro de Patologia e Medicina Laboratorial (Brazilian Journal of Pathology and Laboratory Medicine), a continuation of Jornal Brasileiro de Patologia (Brazilian Journal of Pathology), and published quarterly (March, June, September and December) is directed towards the publication of scientific articles that contribute to the development of the area of Laboratory Medicine (Clinical Pathology, Pathology, Cytopathology). It accepts the following categories of articles: original articles, review articles, case reports, short communications, updating articles, letters to editors and reviews.