{"title":"不同养殖池氨浓度","authors":"M. Mustapha, F. Akinshola","doi":"10.4314/WAJAE.V24I1","DOIUrl":null,"url":null,"abstract":"Ammonia was measured in collapsible pond, concrete tank, and earthen pond of the same size, volume and containing same fish biomass cultured under intensive system. Ammonia was also evaluated from a natural pond under extensive culture. Ammonia was measured in the afternoons for 12 weeks using Nessler method. Temperature and p H were measured in situ using Portable tester. Unionized ammonia was calculated from total ammonia using spreadsheet computation. Result showed total ammonia ranging from 1.4 to 10 mg/l with highest concentration recorded in collapsible pond and lowest found in natural pond. The unionized ammonia concentrations followed the same pattern with concentrations ranging from 0.002 to 1.13 mg/l. The trend in the total ammonia and unionized ammonia concentrations is: collapsible pond > concrete tank > earthen pond > natural pond. Temperature and p H ranged between 29.1 to 35.9 °C and 6.35 to 8.03 respectively, with the highest temperature and p H recorded in the collapsible pond and lowest temperature and p H found in natural pond. Temperature and p H followed seasonal pattern with lowest and highest temperatures and p H recorded at the end of rainy season and in the dry season respectively. High unionized ammonia recorded in the collapsible and concrete ponds was from excretion of high protein rich feed, decomposition of uneaten feed, high stocking density, low water exchange rates, water source and the alkaline medium of the systems. Low unionized ammonia in earthen pond and natural pond was attributed to the presence of phytoplankton, high water exchanges, feeding system, low acidity and relatively low temperature. Remediating measures such as the use of biofilters, aeration and reduction in feeding, temperature and p H should be employed to reduce the high concentration of unionized ammonia.","PeriodicalId":39286,"journal":{"name":"West African Journal of Applied Ecology","volume":"24 1","pages":"1-8"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Ammonia Concentrations in Different Aquaculture Holding Tanks\",\"authors\":\"M. Mustapha, F. Akinshola\",\"doi\":\"10.4314/WAJAE.V24I1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ammonia was measured in collapsible pond, concrete tank, and earthen pond of the same size, volume and containing same fish biomass cultured under intensive system. Ammonia was also evaluated from a natural pond under extensive culture. Ammonia was measured in the afternoons for 12 weeks using Nessler method. Temperature and p H were measured in situ using Portable tester. Unionized ammonia was calculated from total ammonia using spreadsheet computation. Result showed total ammonia ranging from 1.4 to 10 mg/l with highest concentration recorded in collapsible pond and lowest found in natural pond. The unionized ammonia concentrations followed the same pattern with concentrations ranging from 0.002 to 1.13 mg/l. The trend in the total ammonia and unionized ammonia concentrations is: collapsible pond > concrete tank > earthen pond > natural pond. Temperature and p H ranged between 29.1 to 35.9 °C and 6.35 to 8.03 respectively, with the highest temperature and p H recorded in the collapsible pond and lowest temperature and p H found in natural pond. Temperature and p H followed seasonal pattern with lowest and highest temperatures and p H recorded at the end of rainy season and in the dry season respectively. High unionized ammonia recorded in the collapsible and concrete ponds was from excretion of high protein rich feed, decomposition of uneaten feed, high stocking density, low water exchange rates, water source and the alkaline medium of the systems. Low unionized ammonia in earthen pond and natural pond was attributed to the presence of phytoplankton, high water exchanges, feeding system, low acidity and relatively low temperature. Remediating measures such as the use of biofilters, aeration and reduction in feeding, temperature and p H should be employed to reduce the high concentration of unionized ammonia.\",\"PeriodicalId\":39286,\"journal\":{\"name\":\"West African Journal of Applied Ecology\",\"volume\":\"24 1\",\"pages\":\"1-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"West African Journal of Applied Ecology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4314/WAJAE.V24I1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Environmental Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"West African Journal of Applied Ecology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/WAJAE.V24I1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Environmental Science","Score":null,"Total":0}
Ammonia Concentrations in Different Aquaculture Holding Tanks
Ammonia was measured in collapsible pond, concrete tank, and earthen pond of the same size, volume and containing same fish biomass cultured under intensive system. Ammonia was also evaluated from a natural pond under extensive culture. Ammonia was measured in the afternoons for 12 weeks using Nessler method. Temperature and p H were measured in situ using Portable tester. Unionized ammonia was calculated from total ammonia using spreadsheet computation. Result showed total ammonia ranging from 1.4 to 10 mg/l with highest concentration recorded in collapsible pond and lowest found in natural pond. The unionized ammonia concentrations followed the same pattern with concentrations ranging from 0.002 to 1.13 mg/l. The trend in the total ammonia and unionized ammonia concentrations is: collapsible pond > concrete tank > earthen pond > natural pond. Temperature and p H ranged between 29.1 to 35.9 °C and 6.35 to 8.03 respectively, with the highest temperature and p H recorded in the collapsible pond and lowest temperature and p H found in natural pond. Temperature and p H followed seasonal pattern with lowest and highest temperatures and p H recorded at the end of rainy season and in the dry season respectively. High unionized ammonia recorded in the collapsible and concrete ponds was from excretion of high protein rich feed, decomposition of uneaten feed, high stocking density, low water exchange rates, water source and the alkaline medium of the systems. Low unionized ammonia in earthen pond and natural pond was attributed to the presence of phytoplankton, high water exchanges, feeding system, low acidity and relatively low temperature. Remediating measures such as the use of biofilters, aeration and reduction in feeding, temperature and p H should be employed to reduce the high concentration of unionized ammonia.
期刊介绍:
This research journal has been established by the Ecological Laboratory Unit of the University of Ghana, Accra to publish original papers, invited articles and book reviews in English on general ecology. Papers are peer reviewed by consulting editors. The journal is targeted at scientists, policy makers and the general public. The subject areas to be covered include the following: -Theoretical and Applied Ecology- Environmental Studies- Environmental Management- Population Studies- Sustainable use of Natural Resources- Atmospheric Science- Aquatic Sciences and Oceanography- Terrestrial Ecology- Soil Sciences- Human Settlements- Disaster Preparedness and Disaster Reduction- Sustainable Development- Traditional Knowledge on Biodiversity and its sustainable use- Application in Agriculture and Land Use- Health and Environmental Protection