三维表面测量在股骨干磨损表征中的应用

Q3 Engineering
X. Jiang, L. Blunt, L. Brown, Hong-yu Zhang
{"title":"三维表面测量在股骨干磨损表征中的应用","authors":"X. Jiang, L. Blunt, L. Brown, Hong-yu Zhang","doi":"10.3969/J.ISSN.1005-0930.2012.01.016","DOIUrl":null,"url":null,"abstract":"The significance of three dimensional(3D)surface metrology in engineering is firstly discussed,based on the recognition of the limitation of two dimensional(2D)surface metrology that most researchers in academia and industry have been utilizing.Then a detailed description of modern 3D surface metrology instruments,i.e.contacting stylus,non-contacting optical interferometer and atomic force microscope,is given.Subsequently,the development of 3D surface characterization technique which concentrates mainly on 3D surface parameters,especially the famous \"Birmingham 14 Parameters\",is introduced.Finally,a typical case study on the application of 3D surface metrology in characterization of femoral stem wear is proposed to further advocate the popularization of 3D surface metrology in biomedical engineering,with the result showing that matt femoral stems wear against bone cement by an abrasive mechanism whilst fretting wear dominates the wear mechanism between polished femoral stems and bone cement.","PeriodicalId":34897,"journal":{"name":"应用基础与工程科学学报","volume":"20 1","pages":"139-148"},"PeriodicalIF":0.0000,"publicationDate":"2012-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The Application of 3D Surface Metrology in Characterization of Femoral Stem Wear\",\"authors\":\"X. Jiang, L. Blunt, L. Brown, Hong-yu Zhang\",\"doi\":\"10.3969/J.ISSN.1005-0930.2012.01.016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The significance of three dimensional(3D)surface metrology in engineering is firstly discussed,based on the recognition of the limitation of two dimensional(2D)surface metrology that most researchers in academia and industry have been utilizing.Then a detailed description of modern 3D surface metrology instruments,i.e.contacting stylus,non-contacting optical interferometer and atomic force microscope,is given.Subsequently,the development of 3D surface characterization technique which concentrates mainly on 3D surface parameters,especially the famous \\\"Birmingham 14 Parameters\\\",is introduced.Finally,a typical case study on the application of 3D surface metrology in characterization of femoral stem wear is proposed to further advocate the popularization of 3D surface metrology in biomedical engineering,with the result showing that matt femoral stems wear against bone cement by an abrasive mechanism whilst fretting wear dominates the wear mechanism between polished femoral stems and bone cement.\",\"PeriodicalId\":34897,\"journal\":{\"name\":\"应用基础与工程科学学报\",\"volume\":\"20 1\",\"pages\":\"139-148\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"应用基础与工程科学学报\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.3969/J.ISSN.1005-0930.2012.01.016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"应用基础与工程科学学报","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.3969/J.ISSN.1005-0930.2012.01.016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 1

摘要

在认识到目前学术界和产业界普遍采用的二维曲面测量方法存在局限性的基础上,首先讨论了三维曲面测量在工程中的意义。然后详细介绍了现代三维曲面测量仪器,即。给出了接触式触针、非接触式光学干涉仪和原子力显微镜。随后介绍了三维表面表征技术的发展,主要集中在三维表面参数,特别是著名的“伯明翰14参数”。最后,为进一步倡导三维表面测量在生物医学工程中的应用,提出了三维表面测量在股骨柄磨损表征中的典型案例研究,结果表明,磨砂股骨柄对骨水泥的磨损以磨粒机制为主,而磨砂股骨柄与骨水泥的磨损机制以微动磨损为主。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Application of 3D Surface Metrology in Characterization of Femoral Stem Wear
The significance of three dimensional(3D)surface metrology in engineering is firstly discussed,based on the recognition of the limitation of two dimensional(2D)surface metrology that most researchers in academia and industry have been utilizing.Then a detailed description of modern 3D surface metrology instruments,i.e.contacting stylus,non-contacting optical interferometer and atomic force microscope,is given.Subsequently,the development of 3D surface characterization technique which concentrates mainly on 3D surface parameters,especially the famous "Birmingham 14 Parameters",is introduced.Finally,a typical case study on the application of 3D surface metrology in characterization of femoral stem wear is proposed to further advocate the popularization of 3D surface metrology in biomedical engineering,with the result showing that matt femoral stems wear against bone cement by an abrasive mechanism whilst fretting wear dominates the wear mechanism between polished femoral stems and bone cement.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
应用基础与工程科学学报
应用基础与工程科学学报 Engineering-Engineering (all)
CiteScore
1.60
自引率
0.00%
发文量
2784
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信