全身振动训练中的器械缺陷

Suchi Kiranhe
{"title":"全身振动训练中的器械缺陷","authors":"Suchi Kiranhe","doi":"10.35248/2472-1115.21.11.343","DOIUrl":null,"url":null,"abstract":"The fact that WBVT devices produce frequencies, amplitudes, and/or modes of vibration that are different from preset adjustments can obstruct research and practise in whole body vibration training (WBVT). Based on the available research, it can be concluded that major divergences between the preset frequency and the real applied frequency in WBVT devices used in practise and experimental research are to be predicted, but not divergences about the mode of vibration. There were no published research findings on possible divergences of the currently applied amplitude found in the available literature. It would be difficult to determine the most suitable set of frequencies for particular study intentions where there are divergences of more than 10%. In reality, divergences of more than 10% will result in presumed successful WBVT training parameters failing to change a patient's pathology or produce predicted training outcomes in athletes and healthy people. As a result, an inexactly applied frequency may be a factor in the ineffectiveness of a WBVT interference. Based on these findings, users in practise and study should thoroughly examine their WBVT systems in terms of applied frequency and mode of vibration. Divergences in the currently applied amplitude and potential causes of divergences in WBVT devices should be investigated in future studies.","PeriodicalId":89697,"journal":{"name":"Journal of yoga & physical therapy","volume":"11 1","pages":"1-343"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Device Defects in Whole-Body Vibration Training\",\"authors\":\"Suchi Kiranhe\",\"doi\":\"10.35248/2472-1115.21.11.343\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The fact that WBVT devices produce frequencies, amplitudes, and/or modes of vibration that are different from preset adjustments can obstruct research and practise in whole body vibration training (WBVT). Based on the available research, it can be concluded that major divergences between the preset frequency and the real applied frequency in WBVT devices used in practise and experimental research are to be predicted, but not divergences about the mode of vibration. There were no published research findings on possible divergences of the currently applied amplitude found in the available literature. It would be difficult to determine the most suitable set of frequencies for particular study intentions where there are divergences of more than 10%. In reality, divergences of more than 10% will result in presumed successful WBVT training parameters failing to change a patient's pathology or produce predicted training outcomes in athletes and healthy people. As a result, an inexactly applied frequency may be a factor in the ineffectiveness of a WBVT interference. Based on these findings, users in practise and study should thoroughly examine their WBVT systems in terms of applied frequency and mode of vibration. Divergences in the currently applied amplitude and potential causes of divergences in WBVT devices should be investigated in future studies.\",\"PeriodicalId\":89697,\"journal\":{\"name\":\"Journal of yoga & physical therapy\",\"volume\":\"11 1\",\"pages\":\"1-343\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of yoga & physical therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35248/2472-1115.21.11.343\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of yoga & physical therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35248/2472-1115.21.11.343","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

全身振动训练(WBVT)装置产生的频率、振幅和/或振动模式与预设调整不同,这一事实阻碍了全身振动训练(WBVT)的研究和实践。根据已有的研究,可以预测实际和实验研究中使用的WBVT装置的预设频率与实际应用频率之间的主要偏差,而不是振动模态的偏差。在现有文献中,没有发现关于当前应用振幅可能出现的分歧的已发表的研究结果。对于差异超过10%的特定研究意图,很难确定最合适的频率集。在现实中,超过10%的差异将导致假定成功的WBVT训练参数不能改变患者的病理,也不能在运动员和健康人身上产生预测的训练结果。因此,应用频率不准确可能是WBVT干扰无效的一个因素。基于这些发现,在实践和研究中,用户应该在应用频率和振动模式方面彻底检查他们的WBVT系统。在未来的研究中,应研究WBVT装置中当前应用振幅的差异和潜在的差异原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Device Defects in Whole-Body Vibration Training
The fact that WBVT devices produce frequencies, amplitudes, and/or modes of vibration that are different from preset adjustments can obstruct research and practise in whole body vibration training (WBVT). Based on the available research, it can be concluded that major divergences between the preset frequency and the real applied frequency in WBVT devices used in practise and experimental research are to be predicted, but not divergences about the mode of vibration. There were no published research findings on possible divergences of the currently applied amplitude found in the available literature. It would be difficult to determine the most suitable set of frequencies for particular study intentions where there are divergences of more than 10%. In reality, divergences of more than 10% will result in presumed successful WBVT training parameters failing to change a patient's pathology or produce predicted training outcomes in athletes and healthy people. As a result, an inexactly applied frequency may be a factor in the ineffectiveness of a WBVT interference. Based on these findings, users in practise and study should thoroughly examine their WBVT systems in terms of applied frequency and mode of vibration. Divergences in the currently applied amplitude and potential causes of divergences in WBVT devices should be investigated in future studies.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信