S. Bekkouche, T. Benouaz, M. Hamdani, M. K. Cherier, M. Yaiche, N. Benamrane
{"title":"撒哈拉气候条件下基于水平密实度的建筑热风性能建模与试验","authors":"S. Bekkouche, T. Benouaz, M. Hamdani, M. K. Cherier, M. Yaiche, N. Benamrane","doi":"10.3846/2029882X.2016.1211492","DOIUrl":null,"url":null,"abstract":"AbstractA large number of studies of building energy simulation neglect the humidity, or well represented, with a very simplified method. It is for this reason that we have developed a new approach to the description and modelling of multizone buildings in Saharan climate. The concept of the form factor and index compactness “quotient of external walls area and volume of the building” are two of the key elements for analyzing the building geometry. We can introduce it’s as validation tools in some cases.In this paper, governing equations of physical phenomena allow to build a model of the thermo-aeraulic behavior. The primary objective is the validation of numerical results able to determine the humidity and temperature in a multizone space. The calculated results were compared with firstly, experimental values, and secondly with simulated results using TRNSYS software. We check if the results change radically for an invariable compactness index.The comparison shows that the found results are to some exte...","PeriodicalId":11839,"journal":{"name":"Engineering Structures and Technologies","volume":"8 1","pages":"117-130"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3846/2029882X.2016.1211492","citationCount":"3","resultStr":"{\"title\":\"Modelling and experiment of buildings thermo-aeraulic behavior according to the level-compactness in Saharan climate conditions\",\"authors\":\"S. Bekkouche, T. Benouaz, M. Hamdani, M. K. Cherier, M. Yaiche, N. Benamrane\",\"doi\":\"10.3846/2029882X.2016.1211492\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"AbstractA large number of studies of building energy simulation neglect the humidity, or well represented, with a very simplified method. It is for this reason that we have developed a new approach to the description and modelling of multizone buildings in Saharan climate. The concept of the form factor and index compactness “quotient of external walls area and volume of the building” are two of the key elements for analyzing the building geometry. We can introduce it’s as validation tools in some cases.In this paper, governing equations of physical phenomena allow to build a model of the thermo-aeraulic behavior. The primary objective is the validation of numerical results able to determine the humidity and temperature in a multizone space. The calculated results were compared with firstly, experimental values, and secondly with simulated results using TRNSYS software. We check if the results change radically for an invariable compactness index.The comparison shows that the found results are to some exte...\",\"PeriodicalId\":11839,\"journal\":{\"name\":\"Engineering Structures and Technologies\",\"volume\":\"8 1\",\"pages\":\"117-130\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3846/2029882X.2016.1211492\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Engineering Structures and Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3846/2029882X.2016.1211492\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering Structures and Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3846/2029882X.2016.1211492","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Modelling and experiment of buildings thermo-aeraulic behavior according to the level-compactness in Saharan climate conditions
AbstractA large number of studies of building energy simulation neglect the humidity, or well represented, with a very simplified method. It is for this reason that we have developed a new approach to the description and modelling of multizone buildings in Saharan climate. The concept of the form factor and index compactness “quotient of external walls area and volume of the building” are two of the key elements for analyzing the building geometry. We can introduce it’s as validation tools in some cases.In this paper, governing equations of physical phenomena allow to build a model of the thermo-aeraulic behavior. The primary objective is the validation of numerical results able to determine the humidity and temperature in a multizone space. The calculated results were compared with firstly, experimental values, and secondly with simulated results using TRNSYS software. We check if the results change radically for an invariable compactness index.The comparison shows that the found results are to some exte...