电fenton法去除水中抗生素甲硝唑的效果评价

A. Hosseinnezhad, M. Khodadadi, N. Nasseh
{"title":"电fenton法去除水中抗生素甲硝唑的效果评价","authors":"A. Hosseinnezhad, M. Khodadadi, N. Nasseh","doi":"10.32592/jbirjandunivmedsci.2020.27.1.105","DOIUrl":null,"url":null,"abstract":"Background and Aim: Metronidazole is one of the antibiotics that are widely used and resistant to biodegradation, it is one of the most important pollutants in the environment. The purpose of the study was to examine the efficacy of the Electro-Fenton process for removing metronidazole from synthetic wastewater using iron electrode under operating different conditions. Materials and Methods: The present study was an experimental, laboratory-scale study that was done discontinuously. The effect of soluble pH variables (11, 9, 7, 5, 3), initial concentration of metronidazole (10, 15, 20, 25 and 30 mg/ L), electrode spacing (0.5, 1, 2 and 3 cm), hydrogen peroxide concentration (50, 100, 150 and 200 mg/L) and current intensity (1, 0.5, 0.3, 0.2 and 0.05 A) with the mixing rate of 100 RPM at ambient temperature was investigated. The reaction kinetics was also studied. The antibiotic concentration was read by UV / Vis T80 + spectrophotometer at 320 nm wavelength. Results: The results showed that at optimum conditions (pH 7, 120 minutes, antibiotic concentration 20 mg / L, the hydrogen peroxide concentration 150 mg / L, inlet current intensity of 0.05 A and electrode spacing of 1 cm), The removal efficiency of metronidazole by Electro-Fenton process was 96.37%. Conclusion: According to the results, it was found that Electro-Fenton with iron electrodes can be used as an effective method in the removal of metronidazole from aqueous solutions.","PeriodicalId":31015,"journal":{"name":"Journal of Birjand University of Medical Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the Electro-Fenton efficiency in removal of Antibiotic Metronidazole from aqueous solutions\",\"authors\":\"A. Hosseinnezhad, M. Khodadadi, N. Nasseh\",\"doi\":\"10.32592/jbirjandunivmedsci.2020.27.1.105\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background and Aim: Metronidazole is one of the antibiotics that are widely used and resistant to biodegradation, it is one of the most important pollutants in the environment. The purpose of the study was to examine the efficacy of the Electro-Fenton process for removing metronidazole from synthetic wastewater using iron electrode under operating different conditions. Materials and Methods: The present study was an experimental, laboratory-scale study that was done discontinuously. The effect of soluble pH variables (11, 9, 7, 5, 3), initial concentration of metronidazole (10, 15, 20, 25 and 30 mg/ L), electrode spacing (0.5, 1, 2 and 3 cm), hydrogen peroxide concentration (50, 100, 150 and 200 mg/L) and current intensity (1, 0.5, 0.3, 0.2 and 0.05 A) with the mixing rate of 100 RPM at ambient temperature was investigated. The reaction kinetics was also studied. The antibiotic concentration was read by UV / Vis T80 + spectrophotometer at 320 nm wavelength. Results: The results showed that at optimum conditions (pH 7, 120 minutes, antibiotic concentration 20 mg / L, the hydrogen peroxide concentration 150 mg / L, inlet current intensity of 0.05 A and electrode spacing of 1 cm), The removal efficiency of metronidazole by Electro-Fenton process was 96.37%. Conclusion: According to the results, it was found that Electro-Fenton with iron electrodes can be used as an effective method in the removal of metronidazole from aqueous solutions.\",\"PeriodicalId\":31015,\"journal\":{\"name\":\"Journal of Birjand University of Medical Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Birjand University of Medical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32592/jbirjandunivmedsci.2020.27.1.105\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Birjand University of Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32592/jbirjandunivmedsci.2020.27.1.105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景与目的:甲硝唑是应用广泛的耐生物降解抗生素之一,是环境中最重要的污染物之一。研究了电fenton法在不同操作条件下铁电极去除合成废水中甲硝唑的效果。材料和方法:本研究是一个实验性的、实验室规模的、不连续的研究。考察了在常温下混合速率为100 RPM时,可溶性pH变量(11、9、7、5、3)、甲硝唑初始浓度(10、15、20、25和30 mg/L)、电极间距(0.5、1、2和3 cm)、过氧化氢浓度(50、100、150和200 mg/L)和电流强度(1、0.5、0.3、0.2和0.05 A)的影响。并对反应动力学进行了研究。采用紫外/可见T80 +分光光度计在320 nm波长处读取抗生素浓度。结果:在最佳条件下(pH 7、120 min、抗生素浓度20 mg / L、过氧化氢浓度150 mg / L、进口电流强度0.05 A、电极间距1 cm),电fenton法对甲硝唑的去除率为96.37%。结论:铁电极电fenton法可作为一种有效的去除水溶液中甲硝唑的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of the Electro-Fenton efficiency in removal of Antibiotic Metronidazole from aqueous solutions
Background and Aim: Metronidazole is one of the antibiotics that are widely used and resistant to biodegradation, it is one of the most important pollutants in the environment. The purpose of the study was to examine the efficacy of the Electro-Fenton process for removing metronidazole from synthetic wastewater using iron electrode under operating different conditions. Materials and Methods: The present study was an experimental, laboratory-scale study that was done discontinuously. The effect of soluble pH variables (11, 9, 7, 5, 3), initial concentration of metronidazole (10, 15, 20, 25 and 30 mg/ L), electrode spacing (0.5, 1, 2 and 3 cm), hydrogen peroxide concentration (50, 100, 150 and 200 mg/L) and current intensity (1, 0.5, 0.3, 0.2 and 0.05 A) with the mixing rate of 100 RPM at ambient temperature was investigated. The reaction kinetics was also studied. The antibiotic concentration was read by UV / Vis T80 + spectrophotometer at 320 nm wavelength. Results: The results showed that at optimum conditions (pH 7, 120 minutes, antibiotic concentration 20 mg / L, the hydrogen peroxide concentration 150 mg / L, inlet current intensity of 0.05 A and electrode spacing of 1 cm), The removal efficiency of metronidazole by Electro-Fenton process was 96.37%. Conclusion: According to the results, it was found that Electro-Fenton with iron electrodes can be used as an effective method in the removal of metronidazole from aqueous solutions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
18 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信