提高骨盆后倾运动效率的新型视觉反馈系统的可靠性

G. Mengi, A. Gencay-Can, N. Demirsoy, Emrah Tomsuk, B. Koku, M. Beyazova
{"title":"提高骨盆后倾运动效率的新型视觉反馈系统的可靠性","authors":"G. Mengi, A. Gencay-Can, N. Demirsoy, Emrah Tomsuk, B. Koku, M. Beyazova","doi":"10.3109/10582452.2014.907859","DOIUrl":null,"url":null,"abstract":"Abstract Objectives: This study aimed to develop and assess the reliability of a visual feedback system intended to improve the patient’s perception and the performance of posterior pelvic tilt [PPT] exercises. The feedback setup designed and constructed by the authors included a bed covered with a mat with three embedded force sensors corresponding to the lumbosacral region of the subject lying supine; a data acquisition card to collect and convert data; and two monitors, one above the subject and one on the physician’s table. Software was developed to monitor the force exerted vertically upon the force sensors during PPT to be followed both by the physician and the subject. Methods: Fifteen healthy volunteers were enrolled for a relability trial. The subjects were asked to perform five consecutive PPT with maximum effort. Each subject was evualated three times by two physicians. Intraclass correlation coefficients (ICC) were computed to determine the intrarater and interrater reliability of the maximum force values measured by the visual feedback PPT exercise system. Results: The ICC were 0.89 and 0.98 for intrarater and 0.89, 0.89, and 0.96 for interrater reliability. Conclusions: The novel visual feedback system for PPT proved to be highly reliable for both intrarater and interrater measurements of maximum force.","PeriodicalId":50121,"journal":{"name":"Journal of Musculoskeletal Pain","volume":"22 1","pages":"237 - 241"},"PeriodicalIF":0.0000,"publicationDate":"2014-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10582452.2014.907859","citationCount":"0","resultStr":"{\"title\":\"Reliability of a Novel Visual Feedback System Developed for Increasing the Efficiency of Posterior Pelvic Tilt Exercise\",\"authors\":\"G. Mengi, A. Gencay-Can, N. Demirsoy, Emrah Tomsuk, B. Koku, M. Beyazova\",\"doi\":\"10.3109/10582452.2014.907859\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Objectives: This study aimed to develop and assess the reliability of a visual feedback system intended to improve the patient’s perception and the performance of posterior pelvic tilt [PPT] exercises. The feedback setup designed and constructed by the authors included a bed covered with a mat with three embedded force sensors corresponding to the lumbosacral region of the subject lying supine; a data acquisition card to collect and convert data; and two monitors, one above the subject and one on the physician’s table. Software was developed to monitor the force exerted vertically upon the force sensors during PPT to be followed both by the physician and the subject. Methods: Fifteen healthy volunteers were enrolled for a relability trial. The subjects were asked to perform five consecutive PPT with maximum effort. Each subject was evualated three times by two physicians. Intraclass correlation coefficients (ICC) were computed to determine the intrarater and interrater reliability of the maximum force values measured by the visual feedback PPT exercise system. Results: The ICC were 0.89 and 0.98 for intrarater and 0.89, 0.89, and 0.96 for interrater reliability. Conclusions: The novel visual feedback system for PPT proved to be highly reliable for both intrarater and interrater measurements of maximum force.\",\"PeriodicalId\":50121,\"journal\":{\"name\":\"Journal of Musculoskeletal Pain\",\"volume\":\"22 1\",\"pages\":\"237 - 241\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-08-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10582452.2014.907859\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Musculoskeletal Pain\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10582452.2014.907859\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Musculoskeletal Pain","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10582452.2014.907859","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

摘要目的:本研究旨在开发和评估视觉反馈系统的可靠性,该系统旨在改善患者骨盆后倾[PPT]运动的感知和表现。作者设计和构建的反馈装置包括:一张铺有垫子的床,上面嵌入三个与受试者仰卧时腰骶区相对应的力传感器;用于采集和转换数据的数据采集卡;还有两个监视器,一个在受试者上方,一个在医生的手术台上。我们开发了软件来监测PPT过程中垂直施加在力传感器上的力,以便医生和受试者都能跟踪。方法:选取15名健康志愿者进行可靠性试验。受试者被要求以最大的努力连续做五次PPT。每位受试者由两位医生进行三次评估。计算组内相关系数(ICC)来确定视觉反馈PPT练习系统测得的最大力值的组内和组间可靠性。结果:量表内信度的ICC分别为0.89、0.98,量表间信度的ICC分别为0.89、0.89、0.96。结论:新型的PPT视觉反馈系统在舌内和舌间测量最大力时都是高度可靠的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reliability of a Novel Visual Feedback System Developed for Increasing the Efficiency of Posterior Pelvic Tilt Exercise
Abstract Objectives: This study aimed to develop and assess the reliability of a visual feedback system intended to improve the patient’s perception and the performance of posterior pelvic tilt [PPT] exercises. The feedback setup designed and constructed by the authors included a bed covered with a mat with three embedded force sensors corresponding to the lumbosacral region of the subject lying supine; a data acquisition card to collect and convert data; and two monitors, one above the subject and one on the physician’s table. Software was developed to monitor the force exerted vertically upon the force sensors during PPT to be followed both by the physician and the subject. Methods: Fifteen healthy volunteers were enrolled for a relability trial. The subjects were asked to perform five consecutive PPT with maximum effort. Each subject was evualated three times by two physicians. Intraclass correlation coefficients (ICC) were computed to determine the intrarater and interrater reliability of the maximum force values measured by the visual feedback PPT exercise system. Results: The ICC were 0.89 and 0.98 for intrarater and 0.89, 0.89, and 0.96 for interrater reliability. Conclusions: The novel visual feedback system for PPT proved to be highly reliable for both intrarater and interrater measurements of maximum force.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Musculoskeletal Pain
Journal of Musculoskeletal Pain 医学-风湿病学
自引率
0.00%
发文量
0
审稿时长
>12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信