火电厂三种不同负荷的火用分析

IF 0.7 Q3 ENGINEERING, MULTIDISCIPLINARY
Nurdin Ćehajić
{"title":"火电厂三种不同负荷的火用分析","authors":"Nurdin Ćehajić","doi":"10.31803/tg-20211214151555","DOIUrl":null,"url":null,"abstract":"This paper presents the energy and exergy analysis of thermal power plant Tuzla in Tuzla, Bosnia and Herzegovina. The main aim of this paper is to analyze the components of a 200 MW steam power plant unit in order to identify and quantify the sites with the highest exergy losses and to calculate exergy efficiency values of all components when operating at nominal load. The influence of the change in ambient temperature and block load on the value of exergy losses and exergy efficiency was taken into analysis. The analysis further includes the impact of steam block operation without high-pressure and low-pressure heaters on the exergy efficiency of the steam block. The goal of the analysis is to determine the functional state of individual steam block components after a long period of exploitation and maintenance in order to take appropriate measures to improve their technical performance. Exergy losses during nominal operation of the steam power plant unit are the largest in boiler and amount to 313.42 MW, followed by a turbine with 205.60 MW, condenser 1 with 6.03 MW, condenser 2 with 5.75 MW, while other components of the steam power plant have exergy losses in the range of 0.03 to 2.15 MW. Operation of the unit at nominal load without HPH results in an exergy efficiency decrease from 5.60 to 9.80 %, while in case of operation without HPH and LPH it results in a decrease in exergy efficiency from 9.86 to 16.40 % depending on the pattern used to calculate. The conclusion after the analysis indicates that the biggest exergy losses are in the boiler and turbine and consequently these components have the lowest exergy efficiency values. The increase in ambient temperature has different effects on individual components of the thermal power plant, increasing exergy losses of the boiler while reducing the turbine exergy losses and condensers.","PeriodicalId":43419,"journal":{"name":"TEHNICKI GLASNIK-TECHNICAL JOURNAL","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2023-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Exergy Analysis of Thermal Power Plant for Three Different Loads\",\"authors\":\"Nurdin Ćehajić\",\"doi\":\"10.31803/tg-20211214151555\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the energy and exergy analysis of thermal power plant Tuzla in Tuzla, Bosnia and Herzegovina. The main aim of this paper is to analyze the components of a 200 MW steam power plant unit in order to identify and quantify the sites with the highest exergy losses and to calculate exergy efficiency values of all components when operating at nominal load. The influence of the change in ambient temperature and block load on the value of exergy losses and exergy efficiency was taken into analysis. The analysis further includes the impact of steam block operation without high-pressure and low-pressure heaters on the exergy efficiency of the steam block. The goal of the analysis is to determine the functional state of individual steam block components after a long period of exploitation and maintenance in order to take appropriate measures to improve their technical performance. Exergy losses during nominal operation of the steam power plant unit are the largest in boiler and amount to 313.42 MW, followed by a turbine with 205.60 MW, condenser 1 with 6.03 MW, condenser 2 with 5.75 MW, while other components of the steam power plant have exergy losses in the range of 0.03 to 2.15 MW. Operation of the unit at nominal load without HPH results in an exergy efficiency decrease from 5.60 to 9.80 %, while in case of operation without HPH and LPH it results in a decrease in exergy efficiency from 9.86 to 16.40 % depending on the pattern used to calculate. The conclusion after the analysis indicates that the biggest exergy losses are in the boiler and turbine and consequently these components have the lowest exergy efficiency values. The increase in ambient temperature has different effects on individual components of the thermal power plant, increasing exergy losses of the boiler while reducing the turbine exergy losses and condensers.\",\"PeriodicalId\":43419,\"journal\":{\"name\":\"TEHNICKI GLASNIK-TECHNICAL JOURNAL\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2023-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TEHNICKI GLASNIK-TECHNICAL JOURNAL\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31803/tg-20211214151555\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TEHNICKI GLASNIK-TECHNICAL JOURNAL","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31803/tg-20211214151555","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了波黑图兹拉图兹拉热电厂的能量和火用分析。本文的主要目的是分析200mw蒸汽发电厂机组的组成,以确定和量化具有最高火用损失的站点,并计算所有组件在额定负荷下运行时的火用效率值。分析了环境温度和块负荷的变化对火用损失值和火用效率的影响。进一步分析了无高压加热器和低压加热器的蒸汽块运行对蒸汽块火用效率的影响。分析的目的是确定各个蒸汽块部件经过长时间的开发和维护后的功能状态,以便采取适当的措施提高其技术性能。蒸汽电厂机组标称运行时火用损失最大的是锅炉,为313.42 MW,其次是汽轮机205.60 MW、凝汽器1 6.03 MW、凝汽器2 5.75 MW,而蒸汽电厂其他部件的火用损失在0.03 ~ 2.15 MW之间。机组在标称负荷下运行时,无高压工况下的火用效率从5.60%下降到9.80%,而在无高压工况和低压工况下运行时,根据计算模式的不同,火用效率从9.86%下降到16.40%。分析结果表明,锅炉和汽轮机的火用损失最大,因此这两个部件的火用效率值最低。环境温度的升高对火电厂的各个部件有不同的影响,增加了锅炉的火用损失,同时减少了汽轮机和冷凝器的火用损失。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Exergy Analysis of Thermal Power Plant for Three Different Loads
This paper presents the energy and exergy analysis of thermal power plant Tuzla in Tuzla, Bosnia and Herzegovina. The main aim of this paper is to analyze the components of a 200 MW steam power plant unit in order to identify and quantify the sites with the highest exergy losses and to calculate exergy efficiency values of all components when operating at nominal load. The influence of the change in ambient temperature and block load on the value of exergy losses and exergy efficiency was taken into analysis. The analysis further includes the impact of steam block operation without high-pressure and low-pressure heaters on the exergy efficiency of the steam block. The goal of the analysis is to determine the functional state of individual steam block components after a long period of exploitation and maintenance in order to take appropriate measures to improve their technical performance. Exergy losses during nominal operation of the steam power plant unit are the largest in boiler and amount to 313.42 MW, followed by a turbine with 205.60 MW, condenser 1 with 6.03 MW, condenser 2 with 5.75 MW, while other components of the steam power plant have exergy losses in the range of 0.03 to 2.15 MW. Operation of the unit at nominal load without HPH results in an exergy efficiency decrease from 5.60 to 9.80 %, while in case of operation without HPH and LPH it results in a decrease in exergy efficiency from 9.86 to 16.40 % depending on the pattern used to calculate. The conclusion after the analysis indicates that the biggest exergy losses are in the boiler and turbine and consequently these components have the lowest exergy efficiency values. The increase in ambient temperature has different effects on individual components of the thermal power plant, increasing exergy losses of the boiler while reducing the turbine exergy losses and condensers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
TEHNICKI GLASNIK-TECHNICAL JOURNAL
TEHNICKI GLASNIK-TECHNICAL JOURNAL ENGINEERING, MULTIDISCIPLINARY-
CiteScore
1.50
自引率
8.30%
发文量
85
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信