生物光学器件在吲哚菁绿荧光引导下乳腺癌前哨淋巴结活检中的应用

Toshiyuki Kitai, M. Kawashima, M. Toi
{"title":"生物光学器件在吲哚菁绿荧光引导下乳腺癌前哨淋巴结活检中的应用","authors":"Toshiyuki Kitai, M. Kawashima, M. Toi","doi":"10.2174/1876504101002020078","DOIUrl":null,"url":null,"abstract":"Background: The indocyanine green (ICG) fluorescence method is a newly developed technology to facilitate the sentinel node biopsy with the guidance of ICG fluorescence images. However, the surgical technique is still difficult, since the sentinel node cannot be indentified before skin incision and careful dissection of the subcutaneous lymphatic vessels is necessary. In this paper, an axillary pressing technique is introduced. Materials and methods: The subcutaneous lymphatic vessels just under the skin were easily detectable, but the detection of the sentinel nodes deep under the skin was difficult by ordinary observation of the fluorescence images. By pressing the axillary skin against the chest wall, the sentinel node is close to the skin and the fluorescence signal becomes intense enough to be detected. The skin incision was made on the pressure-induced fluorescent spot, and the sentinel node was directly approached with the guidance of fluorescence without dissecting the subcutaneous lymphatic vessels. Results: Pressure-induced fluorescence signal in the axilla was observed in all of 36 cases. Direct approach to the axillary sentinel nodes without tracing the subcutaneous lymphatic vessels was successful in 33 cases. Conclusions: The ICG fluorescence method is reliable and little training is required. The axillary pressing technique is useful to make it more popular.","PeriodicalId":89705,"journal":{"name":"Open surgical oncology journal (Online)","volume":"2 1","pages":"78-82"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Bio-Optical Devices in Indocyanine Green Fluorescence Guided Sentinel Node Biopsy for Breast Cancer~!2009-10-04~!2009-12-23~!2010-05-26~!\",\"authors\":\"Toshiyuki Kitai, M. Kawashima, M. Toi\",\"doi\":\"10.2174/1876504101002020078\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: The indocyanine green (ICG) fluorescence method is a newly developed technology to facilitate the sentinel node biopsy with the guidance of ICG fluorescence images. However, the surgical technique is still difficult, since the sentinel node cannot be indentified before skin incision and careful dissection of the subcutaneous lymphatic vessels is necessary. In this paper, an axillary pressing technique is introduced. Materials and methods: The subcutaneous lymphatic vessels just under the skin were easily detectable, but the detection of the sentinel nodes deep under the skin was difficult by ordinary observation of the fluorescence images. By pressing the axillary skin against the chest wall, the sentinel node is close to the skin and the fluorescence signal becomes intense enough to be detected. The skin incision was made on the pressure-induced fluorescent spot, and the sentinel node was directly approached with the guidance of fluorescence without dissecting the subcutaneous lymphatic vessels. Results: Pressure-induced fluorescence signal in the axilla was observed in all of 36 cases. Direct approach to the axillary sentinel nodes without tracing the subcutaneous lymphatic vessels was successful in 33 cases. Conclusions: The ICG fluorescence method is reliable and little training is required. The axillary pressing technique is useful to make it more popular.\",\"PeriodicalId\":89705,\"journal\":{\"name\":\"Open surgical oncology journal (Online)\",\"volume\":\"2 1\",\"pages\":\"78-82\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open surgical oncology journal (Online)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/1876504101002020078\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open surgical oncology journal (Online)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1876504101002020078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

背景:吲哚菁绿(ICG)荧光法是一项在ICG荧光图像指导下进行前哨淋巴结活检的新技术。然而,手术技术仍然是困难的,因为在皮肤切开之前不能识别前哨淋巴结,并且需要仔细剥离皮下淋巴管。本文介绍了一种腋窝加压技术。材料和方法:皮肤下的皮下淋巴管很容易被发现,但普通的荧光图像很难检测到皮肤深处的前哨淋巴结。通过将腋窝皮肤紧贴胸壁,前哨淋巴结靠近皮肤,荧光信号变得足够强烈,可以被检测到。在压力诱导的荧光点处皮肤切口,在荧光引导下直接接近前哨淋巴结,不解剖皮下淋巴管。结果:36例患者腋窝均可见压力诱导的荧光信号。直接入路腋窝前哨淋巴结而不追踪皮下淋巴管33例成功。结论:ICG荧光检测方法可靠,训练少。腋窝按压技术有助于使其更受欢迎。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Bio-Optical Devices in Indocyanine Green Fluorescence Guided Sentinel Node Biopsy for Breast Cancer~!2009-10-04~!2009-12-23~!2010-05-26~!
Background: The indocyanine green (ICG) fluorescence method is a newly developed technology to facilitate the sentinel node biopsy with the guidance of ICG fluorescence images. However, the surgical technique is still difficult, since the sentinel node cannot be indentified before skin incision and careful dissection of the subcutaneous lymphatic vessels is necessary. In this paper, an axillary pressing technique is introduced. Materials and methods: The subcutaneous lymphatic vessels just under the skin were easily detectable, but the detection of the sentinel nodes deep under the skin was difficult by ordinary observation of the fluorescence images. By pressing the axillary skin against the chest wall, the sentinel node is close to the skin and the fluorescence signal becomes intense enough to be detected. The skin incision was made on the pressure-induced fluorescent spot, and the sentinel node was directly approached with the guidance of fluorescence without dissecting the subcutaneous lymphatic vessels. Results: Pressure-induced fluorescence signal in the axilla was observed in all of 36 cases. Direct approach to the axillary sentinel nodes without tracing the subcutaneous lymphatic vessels was successful in 33 cases. Conclusions: The ICG fluorescence method is reliable and little training is required. The axillary pressing technique is useful to make it more popular.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信