纯黑纹身油墨对超声波的衰减

IF 1 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC
Craig S. Carlson;Aurélie Deroubaix;Clement Penny;Michiel Postema
{"title":"纯黑纹身油墨对超声波的衰减","authors":"Craig S. Carlson;Aurélie Deroubaix;Clement Penny;Michiel Postema","doi":"10.23919/SAIEE.2021.9340534","DOIUrl":null,"url":null,"abstract":"Black tattoo ink comprises hydrophobic carbonblack nanoparticles. We hypothesized that black tattoo inkdemonstrates transient dynamic activity in an ultrasound field. Brightness-mode sonography was performed on cylindrical receptacles of different bore diameters, filled with black tattooink, water, saline, or air, using pulsed ultrasound with center frequencies of 13 MHz and 5 MHz. The scattering from black ink itself lasted less than tenminutes. At 13-MHz sonication, a transient drop in sound speed was observed, as well as a transient lessening of scattering from distal phantom tissue. The linear acoustic attenuation coefficient of pure black ink was measured to be 0.15±0.01 dB cm\n<sup>−1</sup>\n MHz\n<sup>−1</sup>\n, equal to whole blood. Low-intensity ultrasonic tattoo removal would be of interestas an alternative to techniques that damage surrounding tissue.","PeriodicalId":42493,"journal":{"name":"SAIEE Africa Research Journal","volume":"112 1","pages":"24-31"},"PeriodicalIF":1.0000,"publicationDate":"2021-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.23919/SAIEE.2021.9340534","citationCount":"2","resultStr":"{\"title\":\"On the attenuation of ultrasound by pure black tattoo ink\",\"authors\":\"Craig S. Carlson;Aurélie Deroubaix;Clement Penny;Michiel Postema\",\"doi\":\"10.23919/SAIEE.2021.9340534\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Black tattoo ink comprises hydrophobic carbonblack nanoparticles. We hypothesized that black tattoo inkdemonstrates transient dynamic activity in an ultrasound field. Brightness-mode sonography was performed on cylindrical receptacles of different bore diameters, filled with black tattooink, water, saline, or air, using pulsed ultrasound with center frequencies of 13 MHz and 5 MHz. The scattering from black ink itself lasted less than tenminutes. At 13-MHz sonication, a transient drop in sound speed was observed, as well as a transient lessening of scattering from distal phantom tissue. The linear acoustic attenuation coefficient of pure black ink was measured to be 0.15±0.01 dB cm\\n<sup>−1</sup>\\n MHz\\n<sup>−1</sup>\\n, equal to whole blood. Low-intensity ultrasonic tattoo removal would be of interestas an alternative to techniques that damage surrounding tissue.\",\"PeriodicalId\":42493,\"journal\":{\"name\":\"SAIEE Africa Research Journal\",\"volume\":\"112 1\",\"pages\":\"24-31\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2021-01-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.23919/SAIEE.2021.9340534\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SAIEE Africa Research Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/9340534/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SAIEE Africa Research Journal","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/9340534/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 2

摘要

黑色纹身油墨包括疏水性炭黑纳米颗粒。我们假设黑色纹身墨水在超声场中表现出短暂的动态活动。使用中心频率为13MHz和5MHz的脉冲超声,在充满黑色纹身墨水、水、盐水或空气的不同孔径的圆柱形容器上进行亮度模式超声。黑色墨水本身的散射持续了不到十分钟。在13MHz的超声处理下,观察到声速的瞬态下降,以及来自远端体模组织的散射的瞬态减少。纯黑色墨水的线性声学衰减系数为0.15±0.01 dB cm−1 MHz−1,相当于全血。低强度的超声波纹身去除将是一种有趣的替代技术,损害周围组织。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On the attenuation of ultrasound by pure black tattoo ink
Black tattoo ink comprises hydrophobic carbonblack nanoparticles. We hypothesized that black tattoo inkdemonstrates transient dynamic activity in an ultrasound field. Brightness-mode sonography was performed on cylindrical receptacles of different bore diameters, filled with black tattooink, water, saline, or air, using pulsed ultrasound with center frequencies of 13 MHz and 5 MHz. The scattering from black ink itself lasted less than tenminutes. At 13-MHz sonication, a transient drop in sound speed was observed, as well as a transient lessening of scattering from distal phantom tissue. The linear acoustic attenuation coefficient of pure black ink was measured to be 0.15±0.01 dB cm −1 MHz −1 , equal to whole blood. Low-intensity ultrasonic tattoo removal would be of interestas an alternative to techniques that damage surrounding tissue.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
SAIEE Africa Research Journal
SAIEE Africa Research Journal ENGINEERING, ELECTRICAL & ELECTRONIC-
自引率
0.00%
发文量
29
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信