可拆卸假体周向夹失效与弯曲循环的关系

Marco Antônio Meloncini, Paulo Eduardo dos Reis Cardoso, Rosa Helena Miranda Grande, A. Muench
{"title":"可拆卸假体周向夹失效与弯曲循环的关系","authors":"Marco Antônio Meloncini, Paulo Eduardo dos Reis Cardoso, Rosa Helena Miranda Grande, A. Muench","doi":"10.1590/S0103-06631998000300011","DOIUrl":null,"url":null,"abstract":"The purpose of this research was to study the frequency of retention loss of removable partial denture clasps. Loss of retention was determined after several cycling periods (initially zero, and 1, 5, 15 and 25 thousand). Frequency was based on the number of vacant spaces when the clasp failed by rupture or retention loss under 120g. Thus, the number of vacant spaces depends on the number of clasps fractured and/or that lost retention. Other variables were: four base metal alloys, two types of clasps (standard and extra, which was thinner), and two teeth (premolar and molar). The conclusions were that: the number of vacant spaces depends on alloys with or without adjustment; with adjustment the extra clasp presented less failures; frequency of clasp failures is very high and almost half occurred up to 1,000 cycles.","PeriodicalId":77611,"journal":{"name":"Revista de odontologia da Universidade de Sao Paulo","volume":"12 1","pages":"257-260"},"PeriodicalIF":0.0000,"publicationDate":"1998-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Falhas de grampos circunferenciais de próteses removíveis em função de ciclagens de flexão\",\"authors\":\"Marco Antônio Meloncini, Paulo Eduardo dos Reis Cardoso, Rosa Helena Miranda Grande, A. Muench\",\"doi\":\"10.1590/S0103-06631998000300011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of this research was to study the frequency of retention loss of removable partial denture clasps. Loss of retention was determined after several cycling periods (initially zero, and 1, 5, 15 and 25 thousand). Frequency was based on the number of vacant spaces when the clasp failed by rupture or retention loss under 120g. Thus, the number of vacant spaces depends on the number of clasps fractured and/or that lost retention. Other variables were: four base metal alloys, two types of clasps (standard and extra, which was thinner), and two teeth (premolar and molar). The conclusions were that: the number of vacant spaces depends on alloys with or without adjustment; with adjustment the extra clasp presented less failures; frequency of clasp failures is very high and almost half occurred up to 1,000 cycles.\",\"PeriodicalId\":77611,\"journal\":{\"name\":\"Revista de odontologia da Universidade de Sao Paulo\",\"volume\":\"12 1\",\"pages\":\"257-260\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista de odontologia da Universidade de Sao Paulo\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/S0103-06631998000300011\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista de odontologia da Universidade de Sao Paulo","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/S0103-06631998000300011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本研究的目的是研究可摘局部义齿卡环固位丢失的频率。在几个循环周期(最初为0,1,5,15,000和25,000)之后确定留存率的损失。频率是基于在120克以下扣环因破裂或保持丧失而失效时的空位数量。因此,空位的数量取决于骨折和/或失去固位的卡环的数量。其他变量是:四种贱金属合金,两种类型的卡环(标准的和额外的,更薄),两颗牙齿(前磨牙和臼齿)。研究结果表明:空腔数与合金有无调整有关;经过调整,多余的搭扣故障减少;卡环失效的频率非常高,几乎一半发生在1000次循环中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Falhas de grampos circunferenciais de próteses removíveis em função de ciclagens de flexão
The purpose of this research was to study the frequency of retention loss of removable partial denture clasps. Loss of retention was determined after several cycling periods (initially zero, and 1, 5, 15 and 25 thousand). Frequency was based on the number of vacant spaces when the clasp failed by rupture or retention loss under 120g. Thus, the number of vacant spaces depends on the number of clasps fractured and/or that lost retention. Other variables were: four base metal alloys, two types of clasps (standard and extra, which was thinner), and two teeth (premolar and molar). The conclusions were that: the number of vacant spaces depends on alloys with or without adjustment; with adjustment the extra clasp presented less failures; frequency of clasp failures is very high and almost half occurred up to 1,000 cycles.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信