微创青光眼手术和CyPass®微支架——青光眼手术的新时代

S. Mosaed
{"title":"微创青光眼手术和CyPass®微支架——青光眼手术的新时代","authors":"S. Mosaed","doi":"10.17925/USOR.2017.10.01.39","DOIUrl":null,"url":null,"abstract":"I n the largest randomized clinical trial to date on a minimally invasive glaucoma surgery device, the CyPass ® Micro-Stent was able to lower intraocular pressure (IOP) more than was modern cataract surgery (phacoemulsification and intraocular lens implantation) alone, and should be considered for patients with mild to moderate glaucoma already scheduled to undergo phacoemulsification surgery. The two-year outcomes of the COMPASS study found mean IOP reductions of 7.4 mmHg in the CyPass Micro-Stent group and no vision-threatening adverse events; more than 98% of subjects in the CyPass Micro-Stent group achieved 20/40 or better best-corrected visual acuity.","PeriodicalId":90077,"journal":{"name":"US ophthalmic review","volume":"10 1","pages":"39"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Minimally Invasive Glaucoma Surgery and CyPass® Micro-Stent—A New Era in Glaucoma Surgery\",\"authors\":\"S. Mosaed\",\"doi\":\"10.17925/USOR.2017.10.01.39\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"I n the largest randomized clinical trial to date on a minimally invasive glaucoma surgery device, the CyPass ® Micro-Stent was able to lower intraocular pressure (IOP) more than was modern cataract surgery (phacoemulsification and intraocular lens implantation) alone, and should be considered for patients with mild to moderate glaucoma already scheduled to undergo phacoemulsification surgery. The two-year outcomes of the COMPASS study found mean IOP reductions of 7.4 mmHg in the CyPass Micro-Stent group and no vision-threatening adverse events; more than 98% of subjects in the CyPass Micro-Stent group achieved 20/40 or better best-corrected visual acuity.\",\"PeriodicalId\":90077,\"journal\":{\"name\":\"US ophthalmic review\",\"volume\":\"10 1\",\"pages\":\"39\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"US ophthalmic review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17925/USOR.2017.10.01.39\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"US ophthalmic review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17925/USOR.2017.10.01.39","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

在迄今为止关于微创青光眼手术装置的最大随机临床试验中,CyPass®微型支架能够比单独的现代白内障手术(超声乳化和人工晶状体植入术)更能降低眼压(IOP),对于已经计划进行超声乳化手术的轻中度青光眼患者应该考虑。COMPASS研究的两年结果发现,CyPass微型支架组平均眼压降低7.4 mmHg,无视力威胁不良事件;CyPass微型支架组98%以上的受试者达到20/40或更好的最佳矫正视力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Minimally Invasive Glaucoma Surgery and CyPass® Micro-Stent—A New Era in Glaucoma Surgery
I n the largest randomized clinical trial to date on a minimally invasive glaucoma surgery device, the CyPass ® Micro-Stent was able to lower intraocular pressure (IOP) more than was modern cataract surgery (phacoemulsification and intraocular lens implantation) alone, and should be considered for patients with mild to moderate glaucoma already scheduled to undergo phacoemulsification surgery. The two-year outcomes of the COMPASS study found mean IOP reductions of 7.4 mmHg in the CyPass Micro-Stent group and no vision-threatening adverse events; more than 98% of subjects in the CyPass Micro-Stent group achieved 20/40 or better best-corrected visual acuity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信