{"title":"无螺栓梁端连接件的结构性能","authors":"S. Shah, N. Sulong, R. Khan, M. Z. Jumaat","doi":"10.18057/ijasc.2017.13.2.4","DOIUrl":null,"url":null,"abstract":"This study examines the structural performance of beam end connectors used as connection device in semi-rigid boltless beam-to-column connections (BCCs) in steel pallet racks (SPRs). A total of six types of specimens were tested which were distinguished by the three different types of beam end connector (BEC) thicknesses and two different numbers of tabs in the (BEC). The experimental testing was performed using double-cantilever test method and the moment-rotation (M-θ) behavior of the connections and key failure modes were evaluated. The influence of variation in the thickness and the number of tabs of the BEC on the behavior of connection was also investigated. Increased connector thickness enabled the connector tabs to sustain higher failure moment. The findings showed that by varying the geometrical properties, the stiffness of the connection was affected at a higher rate as compared to the strength of the connection. A non-linear three dimensional (3D) finite element (FE) model was developed to simulate the experimental investigations. The FE model showed a close agreement with experimental results.","PeriodicalId":56332,"journal":{"name":"Advanced Steel Construction","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Structural performance of boltless beam end connectors\",\"authors\":\"S. Shah, N. Sulong, R. Khan, M. Z. Jumaat\",\"doi\":\"10.18057/ijasc.2017.13.2.4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study examines the structural performance of beam end connectors used as connection device in semi-rigid boltless beam-to-column connections (BCCs) in steel pallet racks (SPRs). A total of six types of specimens were tested which were distinguished by the three different types of beam end connector (BEC) thicknesses and two different numbers of tabs in the (BEC). The experimental testing was performed using double-cantilever test method and the moment-rotation (M-θ) behavior of the connections and key failure modes were evaluated. The influence of variation in the thickness and the number of tabs of the BEC on the behavior of connection was also investigated. Increased connector thickness enabled the connector tabs to sustain higher failure moment. The findings showed that by varying the geometrical properties, the stiffness of the connection was affected at a higher rate as compared to the strength of the connection. A non-linear three dimensional (3D) finite element (FE) model was developed to simulate the experimental investigations. The FE model showed a close agreement with experimental results.\",\"PeriodicalId\":56332,\"journal\":{\"name\":\"Advanced Steel Construction\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Steel Construction\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.18057/ijasc.2017.13.2.4\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Steel Construction","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.18057/ijasc.2017.13.2.4","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Structural performance of boltless beam end connectors
This study examines the structural performance of beam end connectors used as connection device in semi-rigid boltless beam-to-column connections (BCCs) in steel pallet racks (SPRs). A total of six types of specimens were tested which were distinguished by the three different types of beam end connector (BEC) thicknesses and two different numbers of tabs in the (BEC). The experimental testing was performed using double-cantilever test method and the moment-rotation (M-θ) behavior of the connections and key failure modes were evaluated. The influence of variation in the thickness and the number of tabs of the BEC on the behavior of connection was also investigated. Increased connector thickness enabled the connector tabs to sustain higher failure moment. The findings showed that by varying the geometrical properties, the stiffness of the connection was affected at a higher rate as compared to the strength of the connection. A non-linear three dimensional (3D) finite element (FE) model was developed to simulate the experimental investigations. The FE model showed a close agreement with experimental results.
期刊介绍:
The International Journal of Advanced Steel Construction provides a platform for the publication and rapid dissemination of original and up-to-date research and technological developments in steel construction, design and analysis. Scope of research papers published in this journal includes but is not limited to theoretical and experimental research on elements, assemblages, systems, material, design philosophy and codification, standards, fabrication, projects of innovative nature and computer techniques. The journal is specifically tailored to channel the exchange of technological know-how between researchers and practitioners. Contributions from all aspects related to the recent developments of advanced steel construction are welcome.